Bennett Automation Instrument (Shanghai) Co., Ltd
Home>Products>SETRASPC8000 Handheld Air Particle Counter from the United States
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13817879697
  • Address
    5th Floor, No. 11, Lane 4855, Guangfulin Road, Songjiang District, Shanghai
Contact Now
SETRASPC8000 Handheld Air Particle Counter from the United States
SETRASPC8000 Handheld Air Particle Counter from the United States
Product details

The Setra Systems SPC8000 handheld air particle counter is the most advanced and versatile remote particle counter, capable of measuring particles ranging from 0.3 μ m to 25 μ m with a flow rate of 0.1 CFM (2.83 LPM).

6 user selectable particle size channels
SPC8000 reports and displays up to 6 user selectable particle size channels, as well as temperature and relative humidity, flow rate and sensor status, last calibration date, serial number, laser on time, and manufacturing date, for easy maintenance and quality assurance management.

User friendly interface
SPC8000 is easy to configure and can display up to 6 user selectable size channels, as well as temperature and relative humidity. View data in real-time on the screen and generate reports that comply with ISO 14644-1, EU GMP Annex 1, or FS 209E standards through a printer or USB key, or export to SetraSystems data download software. Setra Systems counters can be remotely controlled and monitored through a web browser. The SCP8000 series' mass concentration mode provides approximate density values in units of μ g/m ³ and supports calibration based on density and refractive index to ensure accuracy.

Advanced Data Storage
The SPC8000 series particle counter can store 45000 time stamped particle counts and environmental data records, providing sufficient data redundancy. The instrument is also equipped with a mass concentration mode, which can provide approximate density values in units of μ g/m ³.

allSetra Systems counters comply with ISO 21501-4 and JIS B9921 standards. SPC8000 also ensures compatibility with the built-in pulse height analyzer.

General Specifications

General Parameters(continue)

size range

0.3to25Mm

report

ISO 14644-1,EU GMG Annex 1,FS 209E

Size channel

factory-calibrated0.30.51.02.55.0The10.0MmVariable combination

Inspection Guidelines

50User configurable 'inspection guide'

traffic

0.1CFM(2.83LPM)

communication mode

Ethernet,USB

Battery running time1

10hour

Optional communication mode

wireless802.11b/gTheRS485orRS232

Concentration limit

4.000.000particle/ft3@5%Overlap loss

environmental sensor

Including temperature and relative humidity probes320to12200to50)±1(0.5),15-90%±2%relative humidity

light source

Long service life laser diode

call the police

Alarm for counting of all particle sizes, low battery, sensor failure, environmental sensors, and flow rate

counting efficiency

0.3MmParticles are50%0.45MmThe above particles are100%(comply withJISstandard)

zero count

1A count/5minute(<Two particles/ft3)

comply withISO 21501-4&JISstandard

standard

ISO 21501-4andJIS B9921

count mode

Automatic, manual, real-time measurement, cumulative/Differential, mass concentration, count or concentration

outer surface

Impact resistant molded casing

size(L×W×H)

10 '×5 '×4.5 '(25.4cm×12.9cm×11.4cm)Including handle but not probe

Counting alarm

1to9.999.999A count

weight

2.2lb(1.0kg)

calibration

NISTTraceability (recommended at least once a year)

display

4.3 '(10.9cm)WQVGA(480×272)colorful touch screen

attachment

USBFlash drive, constant velocity probe, temperature box relative humidity sensor, blow filter, battery, data download softwareUSBBeginner's guide and manual for cable, power supply, and power cord speed

Printer (optional)

External thermal printer

Optional Accessories

Printing manuals, suitcases, spare batteries, external chargers, external printers, and constant velocity probes

vacuum source

Internal pump with automatic flow control function

Filter exhaust gas

internalHEPAfilter

number of channels

6

cache

45000A sampling record(Rotating buffer)Including particle counting data, environmental data, location, and time. Can scroll or print on the screen

Custom size channel

Can perform custom size channel calibration

audible alarm

Adjustable built-in alarm

sample location

most1.000Position.20Within characters.50User defined 'Inspection Guidelines'

battery

Detachable lithium-ion battery

Battery charging time

Inside the instrument is4hour(Using an external charger is less than2hour)

sampling time

1Seconds to33hours

report

ISO14644-1,EU GMP Annex 1,FS209E

power

110to240VAC60/60HzUniversal live streaming power supply

Inspection Guidelines

50User configurable 'inspection guide'

working conditions

410to104(50to40);20%to95%,non-condensing

communication mode

Ethernet,USB

Storage conditions

320to12200to50);maximum98%,non-condensing

Optional communication mode

wireless802.11b/gThers485orRS232

warranty

2Annual valid warranty,Optional extended warranty

Specifications are subject to change without prior notice