60
Product details

详情页主图.jpg产品简介.jpg

60XSeries sensors are26GHigh frequency radar level measuring instrument, capable of measuring up to * * distance80Rice. The antenna is further optimizedChemical processing, the new fast microprocessor can perform higher speed signal analysis and processing, making the instrument suitable for reaction vesselsComplex measurement conditions such as solid material silos.

雷达4.jpg

工作原理.jpg

The radar level antenna emits narrow microwave pulses, which are transmitted downwards through the antenna. Microwaves are reflected upon contact with the surface of the measured mediumReturning and being received again by the antenna system, the signal is transmitted to the electronic circuit and automatically converted into a level signal (due to the speed of microwave propagation)The speed is extremely fast, and the time it takes for electromagnetic waves to reach the target and reflect back to the receiver is almost instantaneous.

1.png


The reference surface for measurement is the bottom surface of the thread or the sealing surface of the flange.

Note: When using radar level timing, it is important to ensure that the highest level does not enter the measurement blind zone (as shown in the figure)DThe area shown.产品特点.jpg

  • Small antenna size, easy to install; Non contact radar, no wear and tear, no pollution.

  • Almost not affected by corrosion and foam; Almost unaffected by changes in water vapor, temperature, and pressure in the atmosphere.

  • The severe dust environment has little impact on the operation of high-frequency level meters.

  • Shorter wavelength, better reflection on tilted solid surfaces.

  • The small beam angle and concentrated energy enhance the echo capability while also helping to avoid interference.

  • The measurement blind spot is smaller, and it can also achieve good results for measuring small cans.

  • High signal-to-noise ratio enables better performance even in fluctuating conditions.

  • High frequency is the preferred choice for measuring solids and low dielectric constant media.

技术参数.jpg

model:
601
601
Application: Various corrosive liquids
Measurement range: 10 meters
Process connection: Threads, flanges
Medium temperature: -40~130℃
Process pressure: -0.1~0.3MPa
Accuracy: ±5mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: Exia ⅡC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4... 20mA/HART (two-wire/four wire)/RS485/Mod bus


model:
602 602.png
Application: Liquid that is resistant to temperature, pressure, and slight corrosion
Measurement range: 30 meters
Process connection: Threads, flanges
Medium temperature: -40~250℃
Process pressure: -0.1~4.0MPa
Accuracy: ±3mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: Exia ⅡC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4... 20mA/HART (two-wire/four wire)/RS485/Mod bus


model: 607

607

Application: Sanitary liquid storage containers, highly corrosive containers
Measurement range: 20 meters
Process connection: flange
Medium temperature: -40~250℃
Process pressure: -0.1~0.1MPa
Accuracy: ±3mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: Exia ⅡC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4... 20mA/HART (two-wire/four wire)/RS485/Mod bus


model: 608 608
Application: Solid materials, strong dust, easy crystallization, and condensation occasions
Measurement range: 70 meters
Process connection: Universal flange
Medium temperature: -40~250℃
Process pressure: -0.1~0.1MPa
Accuracy: ±15mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: Exia ⅡC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4... 20mA/HART (two-wire/four wire)/RS485/Mod bus


model: 609 1d717211d7403fbf81c9737f4e9ac30.jpg
Measurement range: liquid 30rice/Fixed block 20rice/Solid powder 15rice
Process connection: Threads, flanges
Medium temperature: -40250
Process pressure:

-0.14.0MPa (flat flange

-0.10.1MPaUniversal flange

Application: Solid particles, powders
refinedDegree: ±10mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: ExiaC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4...20mA/HART(TWO WIRE/four-wire)
RS485/Mod bus


model: 610

d413403d79949c23626cf70d8c0b560.jpg

Application: Solid materials, strong dust, easy crystallization, and condensation occasions
Measurement range: 80 meters
Process connection: Universal flange
Medium temperature: -40~250℃
Process pressure: -0.1~0.1MPa
Accuracy: ±15mm
Protection level: IP67
Frequency range: 26GHz
Explosion proof grade: Exia ⅡC T6 Ga/Exd ia IIC T6 Gb
Signal output: 4... 20mA/HART (two-wire/four wire)/RS485/Mod bus
Shell Sealing between the outer shell and the outer shell cover silicon rubber

Shell window polycarbonate

ground terminal stainless steel
Supply Voltage Standard type

(16~26) V DC


Intrinsically safe type (21. 6~26. 4) V DC

power consumption max 22. 5mA / 1W

Allow ripple

- <100Hz Uss < lV

- (100100K) Hz

Uss < l0mV

Cable parameters Cable entry/plug 1 M20xl. 5 cable entry


1 blind block M20xl. 5

connecting terminal Wire cross-section 2.5mm ²
Output parameters output signal (4~2 0) mA

Communication protocol HART

resolution 1. 6μA

breakdown signal Current output remains unchanged


20. 5mA


22mA


3.9mA

integration time (0~50)s, adjustable
blind area Antenna end
**Measure distance 80 meters
microwave frequency 26GHz
communication interface HART communication protocol
Measurement Interval Approximately 1 second (depending on parameter settings)
adjust time Approximately 1 second (depending on parameter settings)
display resolution 1mm
Working storage and transportation temperature (-40~100) ℃
process temperature (Temperature of antenna part) (-40~250) ℃
pressure Max. 4MPa
shock-proof Mechanical Shock10m/s² , (10~150)Hz


安装工艺.jpg

Installation Guide

2.png



Installed on a diameter1/4Location or1/6Here.


Note: The minimum distance from the tank wall should be200mm.


Note: ① Reference plane② Container center or axis of symmetry






3.png






The top plane of the conical tank can be installed in the middle of the tank topCan ensure measurement to the bottom of the cone.

←←←←←←←←








4.png






When there is a material pile, the antenna should be aligned vertically with the material surface. If the material surfaceuneven,

Large pile angles require the use of universal flanges for adjustmentHorn angleLa LaBa Jin

Align the quantity with the material surface.

Due to the inclined solid surface causing echo attenuation,Even the issue of signal loss)

←←←←←←←←







Typical incorrect installation:

5.png


The conical tank cannot be installed above the feeding port.

Meanwhile, it should be noted that shading and rainproof measures should be taken during outdoor installation.




① Correct② Error







Instruments cannot be installed in the middle of arched or circular tank tops. In addition to generating indirect echoes, it will also be affected by multiple echoesRing. Multiple echoes may be better than real ones

The signal threshold of the echo is still high because multiple echoes can be concentrated through the top. soCannot be installed in the central position.

6.png






① Correct② Error








When there are obstacles in the tank that affect the measurement, a reflector plate must be installed to ensure normal measurement.

7.png





① Correct② Error








Takeover height requirement: It must be ensured that the antenna extends into the tank at least10mmThe distance.

8.png

外形安装尺寸.jpg

Case size 601

1.png 2.png

3.png






6024.png













607







5.png





608











609 610

6.png7.png8.png

  • Parameter Table for Level Gauge Selection

customer information

Company: contacts:

Address: Postal Code:

Telephone: Fax: mobile phone:

Email: Date:Year Month Day

permit

□ Intrinsic Safety Type (Exia IIB T5) □ Intrinsic Safety Type (Exia IIC T6 Ga)

□ Standard type (non explosion proof) □ Intrinsic safety type+Marine license (Exia IIC T6 Ga)

□ Intrinsic safety type+explosion-proof type (Exd [ia] IIC T6 Gb)

Can/Container Information

Tank type:

□ Storage tank □ Reaction tank □ Separation tank □ Marine storage tank

Tank structure: □ Tank material: □ Pressure:

Can size: □ Can height:m□ Diameter:m

Tank roof: □ Arch roof □ Flat roof □ Open top □ Cone roof

Tank bottom: □ Conical bottom □ Flat bottom □ Sloping bottom □ Curved bottom

Installation: □ Top installation □ Side installation

□ Installation of bypass pipe □ Installation of waveguide pipe

Installation and connection of tank top (important information)

Takeover height: Mm pipe diameter: mm

Measurement medium

Medium name: □ Liquid □ Solid □ Mixed medium

Medium temperature: ℃ dielectric constant:

Hanging material: □ Yes □ No

Mixing: □ Yes □ No

Process connection

Thread: (□ G1 189 ″ □ 1 189 ″ NPT) Flange (DN=) Flange (ANSI=)

Power supply: □ 24V DC two-wire system □ 24V DC four wire system □ 220V AC four wire system

Output: □ 4-20mA □ HART

Display: □ Display programming with header □ Display programming without header


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!