Shanghai Huixiang Technology Co., Ltd
Home>Products>RVV cable
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13764370129
  • Address
    6th Floor, Building 1, Huaqiang Science and Technology Park, No. 358 Kefu Road, Jiading District, Shanghai
Contact Now
RVV cable
RVV cable product description RVV wire full name Copper core PVC insulated PVC sheathed flexible wire, also known as lightweight PVC sheathed flexible
Product details

/ueditor/image/2019/07/08/6ce0c3f20c9b76b25a0fa71a00c9c972.jpg

RVV cableproduct description

The full name of RVV wire is copper core PVC insulated PVC sheathed flexible wire, also known as lightweight PVC sheathed flexible wire, commonly known as soft sheathed wireRVV AVVROne of them. Mainly used for power lines, control lines, and signal transmission lines in electrical appliances, instruments, electronic equipment, and automation devices. Specifically, it can be used for anti-theft alarm systems, building intercom systems, etc.

Product Performance

Product Name: RVV Cable, RVV Wire and Cable

Rated voltage: 300V/500V.

Conductor: multi stranded copper conductor, in accordance with GB/T 3956 Class 5 (equivalent to IEC60228.5).

Insulation: Polyvinyl chloride mixture (PVC).

Sheath: Flexible polyvinyl chloride mixture (PVC), gray (RAL7001).

Core wire identification: ≤ 5 cores, colored core wire; Black core wire with white numerical code, yellow green ground wire.

Core number: 2-5 cores, 7-36 cores (products outside the CCC catalog, without CCC certification).

Cross sectional area: 0.75-2.5mm² , 0.5、2.5—35mm² (Products outside the CCC catalog, without CCC certification).

Test voltage: 2000V, 5 minutes.

Insulation resistance:>200M ohms x KM.

Operating temperature: -30~+70 ℃.

Bending radius: 15 times the outer diameter of the cable.

Flame retardant properties: IEC 60 332.1.

Reference standards: GB 5023, IEC60227, HD VDE21.5 S3.

Packaging specifications: 100m, 500m, 1000m.

Technical Parameter

Number of cores x standard cross-section mm

Insulation thickness specified value mm

The specified thickness of the sheath is mm

At 20 ℃, the conductor resistance Ω/km shall not exceed

Copper core

Tin plated copper core

2×0.5

0.5

0.6

39.0

40.1

2X0.75

0.6

0.8

26.0

26.7

2X1

0.6

0.8

19.5

20.0

2X1.5

0.7

0.8

13.3

13.7

2X2.5

0.8

1.0

7.98

8.21

3×0.5

0.6

0.6

39.0

40.1

3X0.75

0.6

0.8

26.0

26.7

3X1

0.6

0.8

19.5

20.0

3X1.5

0.7

0.9

13.3

13.7

3X2.5

0.8

1.1

7.98

8.21

4X0.75

0.6

0.8

26.0

26.7

4X1

0.6

0.9

19.5

20.0

4X1.5

0.7

1.0

13.3

13.7

4X2.5

0.8

1.1

7.98

8.21

5X0.75

0.6

0.9

26.0

26.7

5X1

0.6

0.9

19.5

20.0

5X1.5

0.7

1.1

13.3

13.7

5X2.5

0.8

1.2

7.98

8.21


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!