KR-9200 Computerized Optometry Instrument
Product Features
Adopting the latest refractive and corneal curvature measurement technology, the design is more fashionable, and the screen angle is adjustable
Electric lifting jaw support, automatic eye tracking and focusing(YAxis direction), more intelligent handling
useARMProcessor and latest image processing technology, fast system, clear image
Mature optical path system, humanized automatic fog vision measurement process, effectively reduces errors caused by adjustment, and achieves more accurate measurement
The optical path frame adopts integral die-casting technology, CNC machining, good measurement consistency, and more stable system
Product parameters
Measurement mode |
K/Rmode |
Measure refractive power and corneal curvature |
REFmode |
Measure diopter |
|
KERmode |
Measure corneal curvature |
|
dioptrometry |
Vertex Distance(VD) |
0.0,12.0,13.75,15.0mm |
Sphericity |
-20.00~+20.00D(0.12/0.25Dstep length)(VD=12mm) |
|
Prism degree |
0.00~±10.00D(0.12/0.25Dstep length) |
|
Axis position |
1°~180°(Every step1°) |
|
Pupil distance range |
30~85mm |
|
Minimum measured pupil diameter |
¢2.0mm |
|
Visual standards |
Automatic cloud and fog map |
|
Corneal measurement |
corneal radius |
5~10mm(0.01mmStep size) |
Corneal refractive power |
30.00~67.00D(0.12/0.25DStep size) |
|
Corneal astigmatism |
0.00~-15.00D(0.12/0.25DStep size) |
|
Axis position |
1°~180°(Every step)1° |
|
corneal diameter |
2.0~12.00mm |
|
Product specifications |
monitor |
5.7inchLCDColor LCD display |
Built-in printer |
Thermal printer |
|
power save mode |
5、15No need for automatic screensaver in minutes |
|
power supply |
AC100~240V,50/60Hz,50W |
|
size/weight |
288(W)*500(D)*480(H)mm/14.5kg |
KR-9000 Computerized Refraction Curvature Meter
Product Features
Simultaneously capable of measuring refractive power and corneal curvature
useARMProcessor and the latest image processing technology in China
——The system is fast and the images are clear
Japan's mature optical system, humanized automatic fog vision measurement process, effectively reduces refractive error caused by eye adjustment ——More accurate measurement
The optical path frame adopts integral pressing technology and CNC machining, with good measurement consistency and high accuracy ——The system is more stable
5.7inchLCDColor screen display, more comfortable human-machine interface
Support data transmission with fully automatic comprehensive optometry instruments, greatly improving the accuracy of testing optical efficiency
automaticPDMeasurement function
One click locking function, quickly lock the mobile body
Innovative exterior design, ergonomic structure, providing customers with good aesthetics and comfortable operability
Product parameters
Measurement mode |
K/Rmode |
Measure refractive power and corneal curvature |
REFmode |
Measure diopter |
|
KERmode |
Measure corneal curvature |
|
dioptrometry |
Vertex Distance(VD) |
0.0,12.0,13.75,15.0mm |
Sphericity |
-20.00~+20.00D(0.12/0.25Dstep length)(VD=12mm) |
|
Prism degree |
0.00~±10.00D(0.12/0.25Dstep length) |
|
Axis position |
1°~180°(Every step1°) |
|
Pupil distance range |
30~85mm |
|
Minimum measured pupil diameter |
¢2.0mm |
|
Visual standards |
Automatic cloud and fog map |
|
Corneal measurement |
corneal radius |
5~10mm(0.01mmStep size) |
Corneal refractive power |
30.00~67.00D(0.12/0.25DStep size) |
|
Corneal astigmatism |
0.00~-15.00D(0.12/0.25DStep size) |
|
Axis position |
1°~180°(Every step)1° |
|
corneal diameter |
2.0~12.00mm |
|
Product specifications |
monitor |
5.7inchLCDColor LCD display |
Built-in printer |
Thermal printer |
|
power save mode |
5、15No need for automatic screensaver in minutes |
|
power supply |
AC100~240V,50/60Hz, |
|
size/weight |
288(W)*500(D)*480(H)mm/14.5kg |
RM-9000 Computerized Optometry Instrument
Product Features
useARMProcessor and the latest image processing technology in China
——The system is fast and the images are clear
Japan's mature optical system, user-friendly automatic fog vision measurement process, has Reduce refractive error caused by eye adjustment
——More accurate measurement
The optical path frame adopts integral pressing technology and CNC machining, with good measurement consistency and high accuracy ——The system is more stable
5.7inchLCDColor screen display, more comfortable human-machine interface
Support data transmission with fully automatic comprehensive optometry instruments, greatly improving optometry efficiency
automaticPDMeasurement function
One click locking function, quickly lock the mobile body
Innovative exterior design, ergonomic structure, providing customers with good aesthetics and comfortable operability
Product parameters
dioptrometry |
Vertex distance (VD) |
0.0,12.0,13.75,15.0mm |
Sphericity |
-20.00~+20.00D(0.12/0.25DStep size (VD=12mm) |
|
Prism degree |
0.00~10.00D(0.12/0.25DStep size) |
|
Axis position |
1°~180°(1 ° per step) |
|
Pupil distance range |
45~85MM |
|
Minimum measured pupil diameter |
2.0mm |
|
Visual standards |
Automatic cloud and fog map |
|
Product specifications |
monitor |
5.7Inch LCD color LCD display |
Built-in printer |
Thermal printer |
|
power save mode |
515 minutes without automatic screensaver |
|
power supply |
AC100~240V,50/60Hz |
|
Size/Weight |
288(W)*500(D)*480(H)mm/14kg |
RM-9200 Computerized Optometry Instrument
Stylish design, adjustable screen angle
Electric lifting jaw support, automatic eye tracking and focusing (Y-axis direction), more intelligent operation
Using ARM processors and the latest image processing technology, the system is fast and the images are clear
Mature optical path system, humanized automatic fog vision measurement process, effectively reduces errors caused by adjustment, and achieves more accurate measurement
The optical path frame adopts integral die-casting technology, CNC machining, good measurement consistency, and more stable system
Product parameters
dioptrometry |
0.0,12.0,13.75,15.0mm |
|
Sphericity |
-20.00~+20.00D(0.12/0.25DStep size (VD=12mm) |
|
Prism degree |
0.00~10.00D(0.12/0.25DStep size) |
|
Axis position |
1°~180°(1 ° per step) |
|
Pupil distance range |
45~85MM |
|
Minimum measured pupil diameter |
2.0mm |
|
Visual standards |
Automatic cloud and fog map |
|
Product specifications |
monitor |
5.7Inch LCD color LCD display |
Built-in printer |
Thermal printer |
|
power save mode |
515 minutes without automatic screensaver |
|
power supply |
AC100~240V,50/60Hz |
|
Size/Weight |
288(W)*500(D)*480(H)mm/14kg |