Diagnostic technical parameters | |
Standard fault |
Unbalanced, loose, misaligned and bearing failure |
Can analyze |
Motor, fan, blower, belt and chain drive mechanism, gearbox, coupling, centrifugal pump, piston pump |
Sliding vane pump, propeller pump, screw pump, thread/gear/cam rotary pump, piston compressor | |
Centrifugal compressor, spiral compressor, direct drive equipment, spindle | |
Machine speed range |
200 rpm to 12000 rpm |
Detailed diagnosis content |
Easy to understand conclusions, severity of faults (mild, moderate, severe, extremely severe), repair details |
Characteristic spectral peaks and spectra | |
|
|
Electrical technical parameters | |
Range conversion |
automatic |
A/D converter |
4 channels, 24 bits |
available bandwidth |
2 Hz to 20 kHz |
sampling |
51.2 Hz |
Digital signal processing function |
Automatic configuration of anti aliasing filters, high pass filters, sampling, overlap, windowing, FFT, and averaging |
sampling rate |
2.5 kHz to 50 kHz |
dynamic range |
128 dB |
Signal to Noise Ratio |
100 dB |
FFT resolution |
800 line |
Spectrum Window |
Hanning Window |
Frequency unit |
Hz, orders, cpm |
Amplitude unit |
In/s, mm/s, VdB (USA), VdB * (Europe) |
Non-Volatile Memory |
SD mini storage card, 2 GB memory+user expansion storage slot (for additional storage) |
|
|
General technical parameters | |
Dimensions (height x depth x width) |
18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in) |
Weight (including battery) |
1.9 kg (4.2 lb) |
display |
¼ VGA, 320 × 240 color (5.7-inch diagonal) TFT LCD with LED backlighting |
Input/output connection |
Three axis sensor connection: 4-pin M12 connector |
Single axis sensor connection: BNC connector | |
Tachometer connection: Micro DIN 6-pin connector | |
PC connection: Micro 'B' USB (2.0) connector | |
battery |
Battery type: Lithium ion battery, 14.8 V, 2.55 Ah |
Battery charging time: 3 hours | |
Battery discharge time: 8 hours (under normal conditions) | |
ac adapter |
Input voltage: 100 Vac to 240 Vac |
Input frequency: 50/60 Hz | |
operating system |
WinCE 6.0 Core |
Supported languages |
English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish |
defects liability period |
3 years |
|
|
Environmental parameters | |
operation temperature |
0 ° C to 50 ° C (32 ° F to 122 ° F) |
storage temperature |
-20 ° C to 60 ° C (-4 ° F to 140 ° F) |
Working humidity |
10% to 95% RH (non condensing) |
institutional accreditation |
CHINA RoHS、CSA、CE、C TICK、WEEE |
electromagnetic compatibility |
EN 61326-1:2006, EN 61010:1:2001 2nd edition |
|
|
Technical parameters of sensors | |
sensor type |
accelerometer |
sensitivity |
100 mV/g (± 5 %, 25 °C) |
Acceleration range |
Peak value of 80g |
Amplitude nonlinearity |
1% |
frequency response |
Z: 2 - 7,000 Hz ± 3dB |
X, Y: 2 - 5,000 Hz ± 3dB | |
Power Requirements (IEPE) |
18 V dc to 30 V dc, 2 mA to 10 mA |
Bias output voltage |
12 V dc |
grounding |
Case Ground |
Sensor element design |
PZT Ceramic/Shear Type |
Housing material |
316L stainless steel |
install |
10-32 hexagon head screw, 2-pole rare earth magnet (48 pound tension) |
Output Connector |
4 needles, M12 |
Matching connector |
M12 - F4D |
Non-Volatile Memory |
TEDS 1451.4 compatible |
Vibration limit |
500 g peak value |
Impact limit |
5000 g peak value |
Electromagnetic sensitivity, equivalent g |
100 μ g/Gauss |
seal |
hermetic seal |
temperature range |
-50 ° C to 120 ° C (-58 ° F to 248 ° F) ± 7% |
defects liability period |
a year |
Technical parameters of tachometer | |
Size (Depth x Width) |
2.86 cm x 12.19 cm (1.125 in x 4.80 in) |
weight |
96 g (3.4 oz), Including cables |
power supply |
Powered by 810 vibration diagnostic instrument |
detection |
Class 2 laser diode |
range |
6.0 to 99,999 rpm |
accuracy |
6.0 to 5999.9 rpm: ± 0.01% and ± 1 word |
5999.9 to 99999 rpm: ± 0.05% and ± 1 word | |
resolution |
0.1 rpm |
Effective range |
1 cm to 100 cm (0.4 in to 39.27 in) |
response time |
1 s (> 60 rpm) |
control |
Measure on/off transparent button |
interface |
6-pin Mini DIN |
Cable Length |
50 cm (19.586 in) |
defects liability period |
a year |
Tachometer accessories |
Reflective tape: 1.5 cm x 52.5 cm (0.59 in x 20.67 in) |
Viewer PC software |
|
Low hardware requirements |
1 GB RAM |
Operating system requirements |
Windows XP, Vista |
Qichen Fluke Vibration Tester 805810product overview
A reliable, reproducible, and accurate method for detecting bearing vibration and direct frequency vibration conditions.
Develop a maintenance plan with confidence. For frontline mechanical troubleshooting teams, the Fluke 805 is a reliable vibration point inspection device that requires obtaining reproducible severity level readings of direct frequency vibration and bearing condition.
Use 805 to check the following types of machines:
- Refrigerator (cooling)
- fan
- Cooling tower drive equipment
- centrifugal pump
- Positive displacement pump
- air compressor
- blower
- Universal gearbox (rolling bearings)
- Machine tools (motors, gearboxes, shafts, etc.)
Technical parameters:
Vibration Meter | ||
Low frequency range (direct frequency measurement) |
10 Hz to 1000 Hz |
|
High frequency range (CF+measurement) |
4000 Hz to 20000 Hz |
|
Severity level |
Good, average, unsatisfactory, unacceptable |
|
Vibration limit |
50 g peak (100 g large peak) |
|
A/D converter |
16 bits |
|
Signal to Noise Ratio |
80 dB |
|
sampling rate |
low frequency |
20000 Hz |
high frequency |
80000 Hz |
|
Real time clock backup |
Button cell |
|
sensor | ||
sensitivity |
100 mV g ±10% |
|
Measurement range |
0.01 g to 50 g |
|
Low frequency range (direct frequency measurement) |
10 Hz to 1000 Hz |
|
High frequency range |
4000 Hz to 20000 Hz |
|
resolution |
0.01 g |
|
accuracy |
Within the range of 100 Hz ± 5% of the measured value |
|
Amplitude unit | ||
acceleration |
g, m/sec² |
|
speed |
in/s, mm/s |
|
displacement |
mils, mm |
|
Infrared thermometer (temperature measurement) | ||
range |
-20 ° C to 200 ° C (-4 ° F to 392 ° F) |
|
accuracy |
±2 °C (4 °F) |
|
focal length |
Fixed, approximately~3.8 cm (1.5 in) |
|
External sensors | ||
Fluke supports but does not provide external sensors | ||
Frequency range |
10 Hz to 1000 Hz |
|
Bias voltage (to power supply) |
20 VDC to 22 VDC |
|
Bias current (to power supply) |
5 mA maximum value |
|
Internal software | ||
External Interface |
USB 2.0 (full speed) communication interface |
|
data capacity |
In the database on the built-in flash memory |
|
upgrade |
Through USB socket |
|
storage |
Can store up to 3500 measurement results |
|
radiation | ||
Electrostatic discharge: burst |
Standard EN 61000-4-2 |
|
electromagnetic interference |
Standard EN 61000-4-3 |
|
radiation |
Standard CISPR 11 Level A |
|
Usage environment | ||
operation temperature |
-20 ° C to 50 ° C (-4 ° F to 122 ° F) |
|
Storage temperature |
-30 ° C to 80 ° C (-22 ° F to 176 ° F) |
|
Working humidity |
10% to 95% relative humidity (non condensing) |
|
Operating/Storage Height |
3048 m (10000 ft) altitude |
|
IP protection level |
IP54 |
|
Vibration limit |
500 g peak value |
|
Drop Test |
1 meter |
|
General technical indicators | ||
Type |
AA (2-cell) lithium iron disulfide battery |
|
BATTERY LIFE |
Measure 250 times |
|
Dimensions (length x width x height) |
24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in) |
|
weight |
0.40 kg (0.89 lb) |
|
socket |
USB mini-B 7-pin、 Stereo audio output jack (3.5 mm)Audio plug), external sensor socket (SMB connector) |