Shanghai Equan Pump Industry Co., Ltd
Home>Products>QDL/QDLF lightweight stainless steel multi-stage centrifugal pump
QDL/QDLF lightweight stainless steel multi-stage centrifugal pump
Q lightweight stainless steel multi-stage centrifugal pump is suitable for liquid transfer, circulation and pressurization of hot and cold clean water
Product details

【QDL/QDLFLightweight stainless steel multi-stage centrifugal pump】Product Introduction:
The QDLF vertical stainless steel multi-stage centrifugal pump is designed based on the advantages of our company's ISG type vertical centrifugal pump and DL type vertical multi-stage centrifugal pump. The structure adopts a vertical and segmented form, with the suction and discharge ports of the pump designed in a straight line below, and adopts the best hydraulic model. The axial force of the pump is solved by hydraulic balance method, and the residual axial force is borne by a ball bearing, thus ensuring smooth operation, low noise, small footprint, and convenient decoration. The outer cylinder of the vertical stainless steel multi-stage centrifugal pump is made of stainless steel, which has a beautiful appearance and is particularly suitable for parallel use of multiple pumps in high-rise buildings to reduce the power of a single pump unit and simplify electrical control equipment. Suitable for fire protection, domestic water supply, air conditioning unit circulation, cooling water transportation, etc. in residential buildings, hospitals, hotels, department stores, office buildings, and other high-rise buildings.
【QDL/QDLFLightweight stainless steel multi-stage centrifugal pump】Model meaning:


[Light stainless steel multi-stage centrifugal pump] Product features:
1. By adopting excellent hydraulic models and advanced manufacturing processes, the performance and service life of the pump are greatly improved.
2. Due to the use of mechanical seals made of hard alloy and fluororubber, the reliability of pump operation and the temperature of the conveying medium can be improved.
3. The overcurrent part of the pump is made of stainless steel plate stamped and welded, making the pump suitable for mildly corrosive media.
4. The overall structure is compact, the volume is small, the weight is light, the noise is low, the energy-saving effect is significant, and the maintenance is convenient.
5. The inlet and outlet of the pump are located on the same horizontal line as the pump seat and can be directly used in the pipeline.
6. Using standard motors, users can easily equip motors according to their needs.
7. Intelligent protectors can be equipped according to user needs to effectively protect pumps from dry running, phase loss, overload, etc.
QDLF series lightweight stainless steel multi-stage centrifugal pump usage conditions:
1. Medium temperature: -15 ℃~+120 ℃.
2. The maximum ambient temperature is+40 ℃.
3. The maximum ambient pressure is 10 bar.
4. The maximum import pressure is limited by the maximum environmental pressure.
5. When the density or viscosity of the conveying medium is greater than that of water, it is necessary to consider using a high-power motor.
QDLF series lightweight stainless steel vertical multi-stage centrifugal pump conveying medium:
1. A non flammable and explosive medium that is thin, clean, and free of solid particles or fibers.
2. Such as mineral water, softened water, pure water, clear oil, and other light chemical media.
3. The main material of the vertical stainless steel multi-stage centrifugal pump is stainless steel, which can be used to pump mildly corrosive media.
QDLF series lightweight stainless steel vertical multi-stage centrifugal pump motor selection:
The motor is a fully enclosed, air-cooled two pole standard motor
Protection level: IP55
Insulation level: F
Standard voltage (50Hz): single-phase 220V, three-phase 220V/380V
QDLF Series Lightweight Stainless Steel Vertical Multi stage Centrifugal Pump Product Usage:
Water supply: filtration and transportation of water plants, water supply to different zones of water plants, main pipeline pressurization, and pressurization of high-rise buildings.
Industrial pressurization: process water system, cleaning system, high-pressure flushing system, fire protection system.
Industrial liquid transportation: cooling and air conditioning systems, boiler feedwater and condensing systems, machine tool matching, and transportation of acidic and alkaline media.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator, and water treatment system for swimming pools.
Irrigation: farmland irrigation, sprinkler irrigation, drip irrigation.

Structural diagram of lightweight stainless steel multi-stage centrifugal pump:

QDLF lightweight multi-stage centrifugal pump performance parameter table:

model

Equipped with motor

Q
(m3/h)

1

1.2

1.6

2

2.4

2.8

3.2

3.5

B1

B2

B1+B2

D1

D2

weight
(kg)

QDLF2-20

0.37

H
(m)

18

17

16

15

13

12

10

8

245

215

460

145

118

19

QDLF2-30

0.37

27

26

24

22

20

18

15

12

263

215

478

145

118

19

QDLF2-40

0.55

36

35

33

30

26

24

20

16

281

215

496

145

118

20

QDLF2-50

0.55

45

43

40

37

33

30

24

20

299

215

514

145

118

20

QDLF2-60

0.75

53

52

50

45

40

36

30

24

322

257

579

175

134

25

QDLF2-70

0.75

63

61

57

52

47

41

35

28

340

257

597

175

134

25

QDLF2-90

1.1

80

78

73

67

61

54

45

37

376

257

633

175

134

30

QDLF2-110

1.1

98

95

89

82

73

64

54

44

412

257

669

175

134

30

QDLF2-130

1.5

116

114

106

98

89

78

65

52

465

265

730

195

140

35

QDLF2-150

1.5

134

130

123

112

100

90

73

60

501

265

766

195

140

35

QDLF2-180

2.2

161

157

148

136

121

108

91

76

555

290

845

195

140

40

QDLF2-220

2.2

197

192

180

165

148

130

110

90

627

290

917

195

140

45

QDLF2-260

3

232

228

214

198

179

158

130

110

702

325

1027

215

160

50

model

Equipped with motor
(KW)

Q
(m3/h)

1.5

2

3

4

5

6

7

8

B1

B2

B1+B2

D1

D2

weight
(kg)

QDLF4-20

0.37

H
(m)

19

18

17

15

13

10

8

6

263

215

478

145

118

19

QDLF4-30

0.55

28

27

26

24

20

18

13

10

290

215

505

145

118

20

QDLF4-40

0.75

38

36

34

32

27

24

19

13

321

257

578

175

134

20

QDLF4-50

1.1

47

45

43

40

34

31

23

17

348

257

605

175

134

25

QDLF4-60

1.1

56

54

52

48

41

37

28

20

375

257

632

175

134

25

QDLF4-70

1.5

66

63

61

56

48

43

33

24

419

265

648

195

140

30

QDLF4-80

1.5

74

72

70

64

55

50

38

27

446

265

711

195

140

30

QDLF4-100

2.2

96

90

87

81

71

62

48

34

500

290

790

195

140

30

QDLF4-120

2.2

114

108

104

95

85

75

58

41

554

290

844

195

140

35

QDLF4-140

3

136

126

122

112

101

89

68

48

611

325

936

215

160

35

QDLF4-160

3

152

144

140

129

115

101

78

55

665

325

990

215

160

40

QDLF4-190

4

183

171

168

153

137

122

93

67

746

340

1086

240

178

45

QDLF4-220

4

211

200

192

178

160

138

108

79

827

340

1167

240

178

50

model

Equipped with motor
(KW)

Q
(m3/h)

5

6

7

8

9

10

11

12

B1

B2

B1+B2

D1

D2

weight
(kg)

QDLF8-20

0.75

H
(m)

21

20

19

18

17

16

15

14

371

257

628

175

134

25

QDLF8-30

1.1

31

30

29

27

26

24

23

20

401

257

658

175

134

30

QDLF8-40

1.5

41

40

39

36

35

32

30

27

436

265

701

195

140

30

QDLF8-50

2.2

52

50

48

45

44

41

37

34

466

290

756

195

140

40

QDLF8-60

2.2

62

60

58

54

53

49

45

41

496

290

786

195

140

40

QDLF8-80

3

83

80

78

73

70

65

60

54

561

325

886

215

160

45

QDLF8-100

4

104

100

97

92

88

80

75

68

621

340

961

240

178

55

QDLF8-120

4

125

120

116

111

105

97

90

81

681

340

1021

240

178

55

QDLF8-140

5.5

146

140

136

130

123

113

105

95

776

403

1179

275

206

80

QDLF8-160

5.5

166

160

155

148

140

130

120

108

836

403

1239

275

206

80

QDLF8-180

7.5

187

180

175

167

158

146

135

122

896

403

1299

275

206

90

QDLF8-200

7.5

208

200

194

186

175

162

150

135

956

403

1359

275

206

90

model

Equipped with motor
(KW)

Q
(m3/h)

8

10

12

14

16

18

20

22

B1

B2

B1+B2

D1

D2

weight
(kg)

QDLF16-20

2.2

H
(m)

28

27

26

25

22

21

19

17

406

290

696

195

140

40

QDLF16-30

3

42

41

39

37

34

32

29

26

456

325

781

215

160

50

QDLF16-40

4

56

54

52

50

46

44

38

34

501

340

841

240

178

55

QDLF16-50

5.5

69

68

65

62

58

54

48

43

581

403

984

275

206

70

QDLF16-60

5.5

83

81

78

75

70

64

58

52

626

403

1029

275

206

75

QDLF16-70

7.5

97

95

92

87

82

75

68

61

671

403

1074

275

206

80

QDLF16-80

7.5

111

108

105

100

94

86

77

70

716

403

1119

275

206

80

QDLF16-100

11

139

136

131

125

118

108

97

87

836

505

1341

330

255

140

QDLF16-120

11

167

163

157

150

141

129

116

105

926

505

1431

330

255

145

QDLF16-140

15

194

190

184

175

166

151

136

122

1016

505

1521

330

255

160

QDLF16-160

15

222

217

210

200

189

173

155

140

1106

505

1611

330

255

165

Installation of QDLF series stainless steel vertical multi-stage centrifugal pump:
1. Lightweight centrifugal pumps should be installed vertically on the ground,. Ensure sufficient cold air enters the motor cooling fan during installation. The bottom arrow of the pump indicates the direction of flow through the pump.
2. To minimize the possible noise generated by the pump, anti vibration fasteners are installed on both sides of the pump and between the foundation and the pump body. The docking flange, gasket, bolt, and PJE joint are provided as accessories and must be ordered separately. If necessary, when cleaning, repairing, or replacing the pump, isolation valves should be installed on both sides of the pump to prevent system drainage. The installation pipeline of multi-stage centrifugal pumps should avoid air blockage, especially on the suction side of the pump. The pipe should be installed in such a way that any stretching caused by temperature changes will not affect the pump. If the pump is installed on a long pipe, it should be properly supported both in front and behind as shown.
3. If there is a risk of blockage by stones, leaves, small support bars, etc. in multi-stage centrifugal pumps, measures should be taken to prevent such incidents from happening. Install a filter screen on the straw area.
4. In some installation situations, if the drainage pipe is already installed horizontally or tilted downwards by the pump, the water inside the pump will or will inevitably flow out at intervals, and the pump should be protected from causing the impeller to idle. Installing a faulty pipe with a vacuum valve near the pump can avoid this situation. The highest point of the ring pipe should be at least level with the connecting plate of the pump's motor. This way, the drainage pipe can independently drain water from the pump, and vice versa.
5. When the drain valve is closed, the pump is prohibited from running because it can cause an increase in temperature/vapor formation inside the pump, leading to pump damage. If there is any danger to the operation of the pump when the drainage room is closed, connect a bypass or drain pipe to the outlet to ensure that the smallest amount of liquid flows through the pump. A drain pipe, for example, can be connected to a water tank.
6. QDL and QDLF lightweight centrifugal pumps are the most suitable for small quantities.