characteristic
-
Display: 4 3/4-digit display,Measure AC current with a multimeter,Dual channel,How to measure current with a multimeter,50000 display
-
Analytical ability: 0.01mV, 0.01Ω
-
Accuracy: 0.05% (DC Volt)
-
True Significant Value Test Function (AC+DC)
-
Frequency and capacitance testing function
-
Peak testing function
-
Current wide range measurement function: 5000 uA -10A
-
Low voltage testing function: minimum 2500mV
-
Voltage regulator diode testing function
-
Measurement value saving function
-
Go - NoGo function
-
Automatic backlight
-
Interface: RS—232C
|
| DC/V |
range |
500.00mV |
5.000V,50.000V,500.00V,1000.0V |
| accuracy |
i*0.05%+5d |
| AC/V |
range |
500.00mV |
5.000V,50.000V,500.00V,750.0V |
| accuracy |
I*0.75%+5d |
| AC+DC/V |
range |
500.00mV |
5.000V,50.000V,500.00 |
| accuracy |
1.5%+50d |
2.0%+50d |
| DC/A |
range |
5000.0uA |
500.00mA |
10.000A |
| accuracy |
0.2%+5d |
0.5%+5d |
| shunt |
100ohm |
1ohm |
10Mohm |
| AC/A |
range |
5000.0uA |
500.00mA |
10.000A |
| frequency |
50Hz~1kHz |
| accuracy |
0.75±20d for <40000count 1% for >40000count→20d for
|
| AC+DC/A |
range |
5000.0uA |
500.00mA |
10.000A |
| frequency |
DC~1kHz |
| accuracy |
1.5%±50d for <30000count 2% for >30000count→50d for
|
| Ohm |
range |
50.00ohm |
5.0000k,50.000k,500.00k,5.0000M |
50.000M |
| resolution |
0.01ohm |
0.1ohm,1ohm,10ohm,100ohm |
1k |
| accuracy |
1.0%+20d |
0.2%+5d |
1.0%+10d |
| LV OHM |
range |
5.000K,50.000K,500.00K,5.000m |
50.000M |
| resolution |
1ohm,10ohm,100ohm,1kohm |
10k |
| accuracy |
0.5%+5d |
2.5%+10d |
| nS |
range |
500.0nS |
| resolution |
0.1nS |
| accuracy |
3.0%+5d |
| continuity |
range |
50kohm |
5kohm |
500kohm |
5Mohm |
| input |
short circuit |
open circuit |
short circuit |
open circuit |
short circuit |
open circuit |
short circuit |
open circuit |
| resolution |
buzzing |
buzzing |
buzzing |
buzzing |
buzzing |
buzzing |
buzzing |
buzzing |
| ring |
close |
ring |
close |
ring |
close |
ring |
close |
| accuracy |
<5ohm |
>150ohm |
<50ohm |
>100ohm |
<500ohm |
>1kohm |
<5kohm |
>10kohm |
| Zener diode |
range |
20.000V |
| accuracy |
5%+10d |
| electric current |
1mA |
| open circuit voltage |
15~22V |
| capacitance |
range |
5.000nF |
50.00nF |
5000.0nF |
5.000m |
50.00m |
500.0m |
5.000mF |
— |
| resolution |
1pF |
10pF |
100pF |
1nF |
10nF |
100nF |
1uF |
— |
| accuracy |
5%+10d |
2%+10d |
2%+5d |
3%+10d |
— |
| frequency |
range |
50.00Hz |
500.0Hz |
50.000kHz |
500.00kHz |
5.0000Hz |
| resolution |
0.01Hz |
0.1Hz |
1Hz |
10Hz |
100Hz |
| accuracy |
0.01%±5d |
| pulse width |
range |
200.00ms |
| resolution |
10uSec |
| accuracy |
0.1%+5d |
| Duty cycle |
range |
100% |
| resolution |
0.01% |
| accuracy |
0.1%+5d |
| temperature |
range |
—20~0℃
|
0~150℃
|
150~200℃
|
0→℉
|
k |
| resolution |
0℃
|
5℉=℃±9/5+32
|
k=℃273.1±
|
| accuracy |
±3℃
|
±2℃
|
±2℃
|
| Peak ± detection |
range |
DCmV,DCV,DCuA℉=℃×9/5+32
|
| accuracy |
The peak duration is greater than5msless than10%,Capacitor multimeter,Less than at full scale per measurement range10%
|
|