Shanghai Shunyu Hengping Scientific Instrument Co., Ltd
Home>Products>Proportional dual beam photometer
Proportional dual beam photometer
The UV2900 proportional dual beam photometer adopts a dual beam feedback recording metering system and is a fully automatic scanning high-performance
Product details

UV2900Proportional dual beam photometerMain Features

  • Series products:2900 (1nm version), 2900 (8-speed adjustable version), 2900 (0.1-5.0nm continuous adjustable version)
  • Durable stability:The dual beam dynamic feedback proportional recording metering system and circuit ensure baseline stability and long-term stability of the instrument.
  • Ultra low stray light: Extremely excellent optical system and advanced electronic system ensure instrument stray light ≤ 0.015% T, making high concentration sample test data more accurate.
  • Light source replacement is simple and convenient: imported socket type flange deuterium and tungsten lamps are used, and there is no need for light path debugging when replacing the lamp, making maintenance easier.
  • Full PC operation: equipped with UV-Solution3.0 workstation software, easy to operate, and rich in testing functions.Optional software that meets GMP standards.
  • Measurement of 3D spectra: Creating and analyzing 3D spectra of scanned samples with "dynamic changes".
  • High performance detector:Select imported product photomultiplier tubes to ensure high sensitivity and stability of the instrument.

UV2900Proportional dual beam photometerMain functions

  • Spectral scanning (wavelength scanning): Within the effective wavelength range, scanning intervals of 0.1, 0.5, 1, 2, and 5nm can be set to scan the absorbance A, transmittance, or energy of the sample, and data processing can be performed on the spectrum, such as spectrum scaling, smoothing, arithmetic operations, coordinate adjustment, peak/valley automatic detection, first to fourth derivative spectra, three-dimensional spectra, etc. It can print records as standard reports, export data as Excel files for users to edit, and export spectra as BMP image files.
  • Time scan (dynamic testing):Perform a time scan on the absorbance A or transmittance T of the sample at a specific wavelength, with sampling intervals of 1.0, 2.0, 5.0, 30, and 60 seconds to choose from. Save an additional 10000 data measurements. It can print records as standard reports, export data as Excel files for users to edit, and export graphs as BMP image files.
  • Quantitative measurement:It can perform first-order zero crossing, first-order linear, second-order fitting, third-order fitting standard curves and parameter calibration tests. It can establish standard curves for up to 20 standard sample points, and can choose to measure at single wavelength, dual wavelength or triple wavelength. The data can be exported as Excel files for users to edit.
  • Multi wavelength measurement:The sample transmittance T and absorbance A can be tested under multiple wavelength conditions. Up to 8 wavelength points can be set, and the records can be printed as standard reports. The data can be exported as Excel files for users to edit.
  • DNA/protein analysis:Quickly measure the absorbance of DNA samples at specific wavelengths, and automatically calculate the concentration of deoxyribonucleic acid/protein and DNARatio. There are two built-in standard testing methods, which can also be extended to other wavelengths and factors for measurement and calculation. Records can be printed as standard reports, and data can be exported as Excel files for users to edit.

Technical specifications

2900 series
1nm version 8-speed adjustable version 0.1-5.0nm continuous adjustable version
  • Optical system: Dual beam dynamic feedback proportional recording metering system.
  • Spectral bandwidth: 1nm/0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0nm adjustable/0.1-5.0nm continuously adjustable.
  • Wavelength range: 190-900nm.
  • Allowable error of wavelength:<± 0.3nm.
  • Wavelength repeatability: ≤ 0.1nm.
  • Luminous range: T: 0-200.00% T, A: -4.000-4.000Abs, C: 0-9999.
  • Allowable error for high transmittance: ± 0.3% T.
  • Transmission density repeatability: ≤ 0.1% T.
  • Stray light: ≤ 0.015% T (at 220nm and 360nm).
  • Baseline straightness: ± 0.001A.
  • Baseline drift: ≤ 0.0004A/h (at 500nm).
  • Noise: ± 0.0004Abs.
  • Detector: Imported photomultiplier tube.
  • Optional accessories: automatic six tank, constant temperature colorimetric dish holder, micro colorimetric dish holder, etc.

UV-Solution3.0

time scan Wavelength scanning Multi wavelength measurement