1Programmable thermal shock test chamberProduct Introduction
This series of products is suitable for testing various performance indicators of aerospace products, information electronic instruments and meters, materials, electricians, vehicles, metals, electronic products, various electronic components, wires, cables, etc. in high and low rapid alternating environments For the purpose of quality management
1. GJB150.5A-2009 Temperature Shock Test
2. GB/2423.22-2012/IEC 60068-2-14:2009 Temperature Shock Test
3. GB/T 2424.13-2002/IEC 60068-2-33:1971 Environmental testing for electrical and electronic products
ThePart 2: Test Methods - Guidelines for Temperature Change Testing
3. GJB360B-2009 Temperature Shock Test
4. GB/T 2423.1-2008/IEC6008-2-1-2007 Environmental testing for electrical and electronic products Part 2: Test methods Test A: Low temperature
5. GB/T 2423.2-2008/IEC60068-2-2:2007 Environmental testing for electrical and electronic products Part 2: Test methods Test B: High temperature
6. GB/T 10589-2008 Technical Conditions for Low Temperature Test Chamber
7. GB/T 11158-2008 Technical Conditions for High Temperature Test Chamber
IIIProgrammable thermal shock test chamberTechnical Parameter
project |
describe |
product name |
Thermal Shockbox |
model |
HD-E703-150T |
Sample limitations |
This testing equipment prohibits the testing of samples containing flammable, explosive, and volatile substances; Test for storing corrosive substance samples, test for storing organisms, test for storing strong electromagnetic emission source samples, and storage |
Volume, weight, and size |
|
nominal volume |
150L |
Inner boxeffectivesize |
500×500×600 W×H×D(mm) |
Exterior space |
make an appointment1380×1800×2030 W×H×D(mm) |
weight |
650㎏ |
noise |
75dbWithin (from the front of the machine)1Meters above the ground1.2Measurement at meters) |
maximum power |
33KW |
Maximum current |
45A |
temperature range |
Temperature range in high temperature zone:RT~170℃ Temperature range in low temperature zone:RT~-75℃ Temperature range in the testing area:-40~ 150℃ |
Temperature shock range |
high temperature:60℃~ 150℃low temperature: -10℃ ~ -40℃
|
Control accuracy |
Analysis accuracy: 0.1℃ temperature fluctuation:±1℃ Uniformity of distribution:≤2.5℃ Temperature deviation: ±1℃ |
Cold storage time |
RT→-60℃ ≤40min |
Heat storage time |
RT→170℃≤35min |
Note:The load per cubic meter shall not exceed35kg/m3Heat capacity of steel |
|
pourThe above performance indicators are at an ambient temperature of+25℃, relative humidity ≤ 85%RH、Values measured under no sample conditions |