Johnson Intelligent Technology (Xiamen) Co., Ltd
Home>Products>PowerSYS3.0 Intelligent Monitoring System
PowerSYS3.0 Intelligent Monitoring System
PowerSYS3.0 Intelligent Monitoring System
Product details

PowerSYS3.0 Intelligent Monitoring System

1 Overview
The Power SYS 3.0 intelligent power quality monitoring system is a specialized, highly automated, easy-to-use, high-performance, and highly reliable power management system developed according to user requirements and following the standard specifications of the distribution system. It is suitable for high and low voltage distribution systems. Through telemetry and remote control, it can reasonably allocate loads, achieve optimized operation, effectively save energy, and have records of peak and off peak electricity consumption, providing necessary conditions for energy management. At the same time, electricity is measured separately according to the electricity consumption of lighting sockets, power, air conditioning, and special electricity, providing a basis for energy conservation audits of enterprises and institutions.

With the rapid development of the economy, energy scarcity and environmental degradation have received close global attention. Energy is an important foundation for the development of the national economy. In order to respond to the national call and take the path of sustainable development, energy conservation and consumption reduction are the primary tasks. Among them, electricity consumes a relatively large amount among all energy sources, and the unified management of electricity is particularly important. Only accurate and reliable measurement of electrical energy can truly save energy.

2 System Structure

The Power SYS 3.0 energy management system can measure the energy consumption of low-voltage equipment separately. Its software runs on the Windows operating system, including Windows 2000, Windows NT, Windows XP and other Windows series operating systems. In addition to good compatibility with the company's independently developed instruments, the system also supports hundreds of various hardware devices, including popular boards, comprehensive protection, instruments, PLCs, etc. Support various commonly used power communication protocols, such as CDT protocol issued by the Ministry, POLLING, 1801, 101, DNP and other power protocols.

According to the relevant requirements of the country for electricity measurement, this system measures the electricity consumption by item, including:

(1) Electricity consumption for lighting sockets: used for indoor equipment such as lighting and sockets in the main functional areas of buildings. Mainly including lighting and socket electricity, corridor and emergency lighting electricity, and outdoor landscape lighting electricity.

(2) Air conditioning electricity: mainly includes electricity for cold and hot stations and electricity for air conditioning terminals.

(3) Power consumption: mainly includes electricity for elevators, water pumps, and ventilation fans.

(4) Special electricity usage: mainly includes information centers, laundry rooms, kitchens, restaurants, swimming pools, gyms, or other special electricity usage.

3 Function Introduction

Front end human-computer interaction interface

Design an interactive interface that meets customer requirements; Standard graphic library, convenient for calling and combining; Real time data collection and display; Automatic logical calculation and processing of data information; Remote modification and setting of equipment parameters; Open/close status display and forced operation.

information processing

Using collected information and specific methods for calculation; Statistics on total power, maximum demand, and switch frequency; Collect power factor and set upper and lower limits; Record load conditions and analyze power quality; The collection, processing, and display of temperature and humidity information (this function requires a temperature and humidity controller).

Alarm/Exception/Event Storage

Real time display of phase failure alarm; Storage of communication anomaly records; Record of closing and opening operations; Real time display of daily alarm events; Querying and printing historical events.

Curve and report management settings function

Trend curve of electrical parameters requested by customers; Historical trend of positive/negative reactive power consumption; Design various reports that meet customer needs; Automatically generate daily, monthly, and annual reports for electricity metering; You can set templates and generate corresponding reports based on commonly used MS Excel, making it easy for users to use; Query reports at any time, display and print them.

Backend database management

Widely used database software Access and MS SQL; Establish an open and networked database; Store specified years or all data information; Dynamic linking implemented by software systems; Real time data information updates are secure and reliable; Support C/S and B/S modes to achieve remote data transmission.

Multi level authority root user management

Password login to the backend to ensure secure settings; High authority for low authority management, hierarchical operation, and password modification function for each authority.

Communication management settings

Each serial port can be configured independently, making it easy to operate; Selection of communication protocols for different devices; Communication baud rate can be independently selected; The system automatically performs unified remote control configuration for all devices connected to a certain port of the front-end processor based on the selection result.

Network function

Dual machine hot backup function, supporting redundancy of dual machines, dual networks, dual devices, etc., and adopting the form of hot backup to ensure stable and reliable operation of the system, with simple and convenient configuration. Any machine on the network can be designated as an I/O server (i.e. front-end processor), and other machines on the network can easily retrieve data from that machine.

Other functions and features

The main wiring diagram, trend diagram display, and real-time data display can all be copied on the screen.

Real time display of real-time electricity consumption, switch status, signal status, and cumulative action data of the power station.

Real time display of the current working status of various modules, communication, printers, etc., with automatic alarm for errors.

Display the main wiring diagram, power flow diagram, geographic map and other graphic working conditions normally. The data on it will automatically refresh, and if it is larger than the entire screen, it can roam and move. Display the temperature of each main transformer, equipment voltage, current, and load bar chart normally, and store relevant historical data at regular intervals. Based on operating conditions and on-site conditions, various characteristics of the measured electricity can be modified online. Optimize and expand the system.

It can dynamically display and modify the protection settings within each protection device, and can online switch on and off the various protection functions within the protection device for the modification and operation of various detected electricity levels. The system is equipped with multiple authorization passwords, making the entire system operation and control convenient and reliable.

Support various databases such as ORACAL, SYBASE, SQLSERVER, ACCESS, etc. through the ODBC interface.

The WEB publishing function allows all created images to be published online in HTML format, and remote calculations can be performed by logging in to the WEB server through the Internet using the IE browser to browse real-time system data.

The processing of fault recording can record fault recording data and display waveforms in curve form for analysis.

Accident recollection, which can list the displacement sequence of each switch and the relevant remote measurement data values in the form of a table when the accident occurred.

4 Software interface

4.1 Data Collection

It can collect and process various commonly used remote measurements, remote signals, pulse quantities, etc. in the power system. For example: remote measurement: voltage, current, active power, reactive power, etc; Remote signal quantity: switch status, knife switch position, protection action signal, accident trip total signal, warning signal, etc; Pulse quantity: electrical measurement, frequency, time, equipment parameters, protection settings, etc; Non electricity: temperature, pressure, humidity, fire alarm, anti-theft alarm, etc.

4.2 Alarm Handling

Event alarm: including switch quantity alarm and analog quantity over limit alarm. When an alarm is generated, an alarm window can be automatically pushed out, displaying the alarm information in a list. In the alarm window, browsing, filtering, confirmation and other operations can be completed; When an alarm is generated, it can simultaneously sound, light, voice and other alarms; Can print alarm records.

4.3 Trend Curve Display

It can achieve real-time and historical trend curve display of electrical parameters such as voltage, current, and power, and query the changes in electrical parameters at a certain moment.

4.4 Main interface display

It can be visually represented using a graphical interface based on the installation and layout of the equipment on site, as shown in the distribution diagram of the low-voltage system.

4.5 Real time report display

Can query and print reports, including parameters such as three-phase current, three-phase voltage, power factor, etc

Query of Meter Reading Data for June 6th

Display the electricity meter data for a certain month, which can be customized for query and printed out.

4.7 System Operation Status Diagram

List of system switch values, analog values, and pulse values, recording the number of switch value displacement actions, and protection switch on/off tables for each protection device in the system

Protect the fixed value table, internal signal table of each microcomputer device, and the number of safe operation days of the system. Read the power consumption of each pulse in the system, and provide a list of daily, monthly, and annual statistics.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!