Portable VOC analyzer H5230
Product Introduction H5230 Portable VOC Analyzer, supporting dual detectors of hydrogen flame ionization (FID) and photoionization (PID), widely used
Product details

Product Introduction

H5230 portable VOC analyzer, supporting dual detectors of hydrogen flame ionization (FID) and photoionization (PID), widely used for on-site determination of total hydrocarbons/non methane total hydrocarbons and benzene derivatives in ambient air and pollution source exhaust gases


Standards

HJ/1012-2018 "Technical Requirements and Testing Methods for Portable Monitoring Instruments for Total Hydrocarbons, Methane and Non Methane Total Hydrocarbons in Environmental Air and Waste Gas"

Beijing:DB 11/T 1367-2016 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"

Zhejiang:DB33/2146-2018 "Determination of volatile organic compounds in exhaust gases from fixed pollution sources - Portable hydrogen flame ionization detector method"

SichuanDB51/2377-2017 "Determination of VOCs - Portable hydrogen flame ionization detector method"

Jiangxi:DB36/1101-2019 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"


Product advantages

lStrong on-site detection capability, optionalFID and PID dual detectors, suitable for rapid monitoring of VOCs;

lThe sample flow path adopts silane coating to ensure the reliability of testing;

lZero deviation of methane in the catalytic oxidation separation process of non methane total hydrocarbons;

lNo external air source, no specialized consumables, low maintenance cost;

lMulti application scenarios, with both online analysis and laboratory offline analysis capabilities;

lThe software is fully functional and easy to use, with a handheld data terminal(PDA is wirelessly connected to the host, with a communication distance of up to 100 meters;

lCan be carried by hand and backpack, easy to carry around


Parameters

Parameter range

Detection object

FID detector: total hydrocarbons, methane, non methane total hydrocarbons

GCFID: Benzene, toluene, ethylbenzene, ortho -, meta -, para xylene (BTEX), isopropylbenzene, styrene

GCPID: Measurement of other VOCs components such as ethylbenzene, styrene, formaldehyde, acetaldehyde, and acrolein can be customized for benzene, toluene, ortho -, meta -, and para xylene (BTEX)

measuring range

0-20/200/2000/20000 ppm, Adaptive range

detection limit

FID detector: 10 ppb (methane); GCFID: 50ppb (benzene); GCPID: 1 ppb (benzene)

zero drift

<1%FS/Month

Span Drift

<1%FS/24H

repeatability

≤1%

linear

±1%FS

output

4-20 mA/0-10V/RS232/MODBUS

power supply

AC220V/50Hz

work environment

5~35°C,20~90% RH

Gas interface

1/8 "stainless steel card sleeve

weight

13kg

External dimensions

410 mm×365 mm×220 mm