Product Introduction
H5230 portable VOC analyzer, supporting dual detectors of hydrogen flame ionization (FID) and photoionization (PID), widely used for on-site determination of total hydrocarbons/non methane total hydrocarbons and benzene derivatives in ambient air and pollution source exhaust gases;
Standards
HJ/1012-2018 "Technical Requirements and Testing Methods for Portable Monitoring Instruments for Total Hydrocarbons, Methane and Non Methane Total Hydrocarbons in Environmental Air and Waste Gas"
Beijing:DB 11/T 1367-2016 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"
Zhejiang:DB33/2146-2018 "Determination of volatile organic compounds in exhaust gases from fixed pollution sources - Portable hydrogen flame ionization detector method"
SichuanDB51/2377-2017 "Determination of VOCs - Portable hydrogen flame ionization detector method"
Jiangxi:DB36/1101-2019 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"
Product advantages
lStrong on-site detection capability, optionalFID and PID dual detectors, suitable for rapid monitoring of VOCs;
lThe sample flow path adopts silane coating to ensure the reliability of testing;
lZero deviation of methane in the catalytic oxidation separation process of non methane total hydrocarbons;
lNo external air source, no specialized consumables, low maintenance cost;
lMulti application scenarios, with both online analysis and laboratory offline analysis capabilities;
lThe software is fully functional and easy to use, with a handheld data terminal(PDA is wirelessly connected to the host, with a communication distance of up to 100 meters;
lCan be carried by hand and backpack, easy to carry around;
Parameters |
Parameter range |
|
Detection object |
FID detector: total hydrocarbons, methane, non methane total hydrocarbons |
|
GCFID: Benzene, toluene, ethylbenzene, ortho -, meta -, para xylene (BTEX), isopropylbenzene, styrene | ||
GCPID: Measurement of other VOCs components such as ethylbenzene, styrene, formaldehyde, acetaldehyde, and acrolein can be customized for benzene, toluene, ortho -, meta -, and para xylene (BTEX) | ||
measuring range |
0-20/200/2000/20000 ppm, Adaptive range |
|
detection limit |
FID detector: 10 ppb (methane); GCFID: 50ppb (benzene); GCPID: 1 ppb (benzene) |
|
zero drift |
<1%FS/Month |
|
Span Drift |
<1%FS/24H |
|
repeatability |
≤1% |
|
linear |
±1%FS |
|
output |
4-20 mA/0-10V/RS232/MODBUS |
|
power supply |
AC220V/50Hz |
|
work environment |
5~35°C,20~90% RH |
|
Gas interface |
1/8 "stainless steel card sleeve |
|
weight |
13kg |
|
External dimensions |