Product Introduction
HThe 5210 portable non methane total hydrocarbon analyzer uses a hydrogen flame ionization detector (FID) to detect the concentrations of methane, total hydrocarbons, and non methane total hydrocarbons in real time. It is mainly used for boiler flue gas emissions, automobile exhaust emissions, process exhaust emissions, and environmental air monitoring.
After the sample gas enters the analyzer, it enters through the total hydrocarbon gas pathFID, Measure total hydrocarbons. The solenoid valve automatically switches and enters the FID through the methane gas path to measure methane. The instrument automatically calculates the concentration of non methane total hydrocarbons.
The H5210 portable non methane total hydrocarbon analyzer adopts a high-temperature hydrogen flame ionization detector with a fully sealed design, and can withstand temperatures up to 400 degrees Celsius°CThe rear mounted non heated sampling pump avoids the influence of the pump on the test sample. Compared to the heated sampling pump, the non heated sampling pump is lighter in weight, smaller in size, and has a longer design life. Built in pollutant capture trap, the air is filtered for dust and hydrocarbons to obtain co combustion gas. Series connection of methane gas pathNon methane hydrocarbon catalytic furnace ", where hydrocarbons other than methane are decomposed into CO2andH2O, Methane has no loss.
Standards
HJ/1012-2018 "Technical Requirements and Testing Methods for Portable Monitoring Instruments for Total Hydrocarbons, Methane and Non Methane Total Hydrocarbons in Environmental Air and Waste Gas"
Beijing:DB 11/T 1367-2016 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"
Zhejiang:DB33/2146-2018 "Determination of volatile organic compounds in exhaust gases from fixed pollution sources - Portable hydrogen flame ionization detector method"
SichuanDB51/2377-2017 "Determination of VOCs - Portable hydrogen flame ionization detector method"
Jiangxi:DB36/1101-2019 "Determination of Methane/Total Hydrocarbons/Non Methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Portable Hydrogen Flame Ionization Detector Method"
Shandong: Determination of Total Hydrocarbons, Methane, and Non Methane Total Hydrocarbons in Fixed Source Waste Gas Portable Catalytic Oxidation-Hydrogen Flame Ionization Detector Method "(Draft for Comments)
Jiangsu: Methane/Determination of total hydrocarbons/non methane total hydrocarbons - Portable hydrogen flame ionization detector method "(draft for comments)
Product advantages
lContinuous direct reading of methane, total hydrocarbons, and non methane total hydrocarbon concentrations;
lBuilt in non methane hydrocarbon catalytic furnace;
lPreheat to room temperature200℃Just need10min;
lAdopting solid-state hydrogen storage modules;
lFully sealedFID detector, capable of withstanding temperatures up to 400℃;
lRear mounted non heated sampling pump, with no adsorption and low maintenance capacity;
lSoftware automatic calibration and range selection;
lAutomatic flame sensing and ignition status judgment;
lSupports handheld and backpack support;
Parameters |
Parameter range |
measuring range |
0-10ppm~0-2000ppm |
detection limit |
1 ppb (methane) |
zero drift |
<1%FS/Month |
Span Drift |
<1%FS/24H |
repeatability |
≤1% |
linear |
<1%FS/24H |
output |
4-20 mA/0-10V/RS232/MODBUS |
power supply |
AC220V/50Hz |
work environment |
5~35℃, 20~90% RH |
Gas interface |
1/8 "stainless steel card sleeve |
weight |
9.5kg |
Dimensions (Depth x Width x Height) |
360 mm×335 mm×200 mm |