Shanghai Baotuo Instrument Co., Ltd
Home>Products>Polarization modulation phase contrast microscope BPH-80PMC
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13774333655
  • Address
    No. 1786 Nanlu Road, Nicheng Town, Pudong New Area, Shanghai
Contact Now
Polarization modulation phase contrast microscope BPH-80PMC
Polarization modulation phase contrast microscope BPH-80PMC
Product details
  • Instrument usage:

    BPH-80PMCInverted polarization modulation phase contrast microscope is a multifunctional phase contrast microscope that is compatible with our company's newly developed polarization modulation phase contrast observation system. It is suitable for high-resolution microscopic observation of phase objects, birefringent objects, stained samples, columnar objects, and objects with surface and subsurface features. It can dynamically observe and analyze cell tissues, transparent liquid tissues, and cultured tissues in culture dishes. Mainly used in research institutes, higher education institutions, medical and health care, inspection and quarantine, agriculture, animal husbandry, dairy industry and other departments.

    Performance characteristics:

    Modulation phase contrast observationIt is achieved by converting the phase gradient of light into changes in light intensity, which can form a high contrast, high-resolution image of phase objects that are usually invisible. The imaging is displayed in a three-dimensional state and is mainly used for high-resolution microscopic observation of phase objects, birefringent objects, stained samples, columnar objects, and objects with surface and subsurface features. This instrument is matched with a rotary modulation phase contrast condenser or a pull plate modulation phase contrast condenser, and is compatible with a newly developed modulation phase contrast objective lens(10X20X40X)When used in conjunction, it can present a clear, bright, and three-dimensional field of view effect whether observed at high or low magnification.

    System Introduction:



    Standard configuration:

    Parameters

    total magnification

    100X~400X

    optical system

    Infinite optical system

    eye looking glass

    Head up field large field eyepiece

    WF 10X

    Field of view:Ф22mm

    Eyepiece interfaceФ30mm

    parfocal distance10mm

    Centering eyepiece(TE-3

    Binoculars

    Articulated binocular, observation angle is45Degree, pupillary distance is5375mm

    Infinite flat field achromatic modulation phase contrast objective lens

    Magnification factor

    Numerical Aperture

    Working distance(mm

    Cover glass thickness(mm

    notes

    PL L10X PMC

    0.25

    4.3

    1.2

    Suitable for modulating phase contrast observation, it needs to match the slit in the phase contrast spotlight device

    PL L20X PMC

    0.40

    8.0

    1.2

    PL L40X PMC

    0.60

    3.5

    1.2

    Bright field objective

    10X

    0.25

    4.3

    1.2

    Suitable for bright field observation

    20X(Optional)

    0.40

    8.0

    1.2

    40X(Optional)

    0.60

    3.5

    1.2

    phase contrast objective

    10X(Optional)

    0.25

    4.3

    1.2

    Suitable for phase contrast observation, it needs to match the phase contrast ring plate in the phase contrast spotlight

    20X(Optional)

    0.40

    8.0

    1.2

    40X(Optional)

    0.60

    3.5

    1.2

    converter

    Five hole converter (optional six hole converter)

    condenser

    Long working distance spotlight, working distance55mmRotary modulation phase contrast device, modulation phase contrast observation adaptation

    Long working distance spotlight, working distance55mmPull type modulation phase contrast device, modulation phase contrast observation adaptation (optional)

    Long working distance spotlight, working distance55mmRotary or pull plate phase contrast device, suitable for phase contrast observation (optional)

    Long working distance spotlight, working distance55mmEquipped with a variable aperture stop, suitable for ordinary observation in bright fields (optional)

    stage

    moving range77mm(Vertical)X134.5mm(Horizontal), the movable ruler is detachable

    Focuser

    Coarse micro coaxial adjustment, micro handwheel grid planting:0.002mm

    petri dish

    Bracket

    Tray one

    86mm(Width)X129.5, mm(Long), adaptable to circular culture dishesФ87.5mm

    Tray 2

    34mm(Width)X77.5mm(Long), adaptable to circular culture dishesФ68.5mm

    Plate Three

    57mm(Width)X82mm(Long)

    light source

    6V 30WHalogen lamp, adjustable brightness, can choose high powerLEDIlluminator

    Imaging system parameters:

    l useSony Exmor CMOSBack illuminated sensorsCinterfaceCMOS USB3.0camera;

    l Adopting parallel arrangementA / DConversion technology achieves ultra-low noise and low power consumption;

    l Hardware resolution12M;

    l real time8/12Position switching, arbitraryROIsize

    l Zinc aluminum alloy precisionCNCcasing

    l USB3.0Interface ensures high transmission rate;

    l Ultra-FineTMhardwareIPSVideo streaming engine ensures accurate color reproduction and fast speed;

    l Provide advanced video and image processing application software with the camera;

    l provideWindows/Linux/OSXmulti-platformSDK;Support nativeC/C++, C#/VB.Net, Directshow, Twain API;

    Imaging system model

    Sensor model and size

    pixel(μm)

    GPhotosensitivity

    dark current

    FPS/resolution

    Sample Average

    time of exposure

    E3CSONY12M

    12M/IMX226(C)
    1/1.7“(7.40x5.55)

    1.85x1.85

    280mvwith 1/30s
    0.
    1mv with 1/30s

    25@4000x3000
    50@2048x1080

    1x1

    2x2

    0.1ms~15s

    hardware configuration

    Spectral response range

    380-650nm (In the presence of an infrared cut-off filter)

    white balance

    ROIwhite balance/hand movementTemp-Tintadjust

    Color restoration technology

    Ultra-FineTMhardwareISPVideo processing engine

    Capture and ControlAPI

    Native C/C++, C#/VB.Net, DirectShow, TwainandLabview

    Record Mode

    Images and videos

    Cooling method*

    natural cooling

    Camera working environment

    Working temperature (Celsius)

    -10~ 50

    Storage temperature (Celsius)

    -20~ 60

    Working humidity

    30~80%RH

    Storage humidity

    10~60%RH

    power supply

    The camera passes throughUSBInterface power supply

    Software operating environment

    operating system

    Microsoft®Windows®XP/ Vista / 7 / 8 /10(32 & 64position)

    computer configuration

    CPU:Intel Core 2 2.8GHzor higher

    Memory:2GBOr larger

    USBinterface: USB3.0High speed interface orUSB2.0interface

  • Instrument usage:

    BPH-80PMCInverted polarization modulation phase contrast microscope is a multifunctional phase contrast microscope that is compatible with our company's newly developed polarization modulation phase contrast observation system. It is suitable for high-resolution microscopic observation of phase objects, birefringent objects, stained samples, columnar objects, and objects with surface and subsurface features. It can dynamically observe and analyze cell tissues, transparent liquid tissues, and cultured tissues in culture dishes. Mainly used in research institutes, higher education institutions, medical and health care, inspection and quarantine, agriculture, animal husbandry, dairy industry and other departments.

    Performance characteristics:

    Modulation phase contrast observationIt is achieved by converting the phase gradient of light into changes in light intensity, which can form a high contrast, high-resolution image of phase objects that are usually invisible. The imaging is displayed in a three-dimensional state and is mainly used for high-resolution microscopic observation of phase objects, birefringent objects, stained samples, columnar objects, and objects with surface and subsurface features. This instrument is matched with a rotary modulation phase contrast condenser or a pull plate modulation phase contrast condenser, and is compatible with a newly developed modulation phase contrast objective lens(10X20X40X)When used in conjunction, it can present a clear, bright, and three-dimensional field of view effect whether observed at high or low magnification.

    System Introduction:



    Standard configuration:

    Parameters

    total magnification

    100X~400X

    optical system

    Infinite optical system

    eye looking glass

    Head up field large field eyepiece

    WF 10X

    Field of view:Ф22mm

    Eyepiece interfaceФ30mm

    parfocal distance10mm

    Centering eyepiece(TE-3

    Binoculars

    Articulated binocular, observation angle is45Degree, pupillary distance is5375mm

    Infinite flat field achromatic modulation phase contrast objective lens

    Magnification factor

    Numerical Aperture

    Working distance(mm

    Cover glass thickness(mm

    notes

    PL L10X PMC

    0.25

    4.3

    1.2

    Suitable for modulating phase contrast observation, it needs to match the slit in the phase contrast spotlight device

    PL L20X PMC

    0.40

    8.0

    1.2

    PL L40X PMC

    0.60

    3.5

    1.2

    Bright field objective

    10X

    0.25

    4.3

    1.2

    Suitable for bright field observation

    20X(Optional)

    0.40

    8.0

    1.2

    40X(Optional)

    0.60

    3.5

    1.2

    phase contrast objective

    10X(Optional)

    0.25

    4.3

    1.2

    Suitable for phase contrast observation, it needs to match the phase contrast ring plate in the phase contrast spotlight

    20X(Optional)

    0.40

    8.0

    1.2

    40X(Optional)

    0.60

    3.5

    1.2

    converter

    Five hole converter (optional six hole converter)

    condenser

    Long working distance spotlight, working distance55mmRotary modulation phase contrast device, modulation phase contrast observation adaptation

    Long working distance spotlight, working distance55mmPull type modulation phase contrast device, modulation phase contrast observation adaptation (optional)

    Long working distance spotlight, working distance55mmRotary or pull plate phase contrast device, suitable for phase contrast observation (optional)

    Long working distance spotlight, working distance55mmEquipped with a variable aperture stop, suitable for ordinary observation in bright fields (optional)

    stage

    moving range77mm(Vertical)X134.5mm(Horizontal), the movable ruler is detachable

    Focuser

    Coarse micro coaxial adjustment, micro handwheel grid planting:0.002mm

    petri dish

    Bracket

    Tray one

    86mm(Width)X129.5, mm(Long), adaptable to circular culture dishesФ87.5mm

    Tray 2

    34mm(Width)X77.5mm(Long), adaptable to circular culture dishesФ68.5mm

    Plate Three

    57mm(Width)X82mm(Long)

    light source

    6V 30WHalogen lamp, adjustable brightness, can choose high powerLEDIlluminator

    Imaging system parameters:

    l useSony Exmor CMOSBack illuminated sensorsCinterfaceCMOS USB3.0camera;

    l Adopting parallel arrangementA / DConversion technology achieves ultra-low noise and low power consumption;

    l Hardware resolution12M;

    l real time8/12Position switching, arbitraryROIsize

    l Zinc aluminum alloy precisionCNCcasing

    l USB3.0Interface ensures high transmission rate;

    l Ultra-FineTMhardwareIPSVideo streaming engine ensures accurate color reproduction and fast speed;

    l Provide advanced video and image processing application software with the camera;

    l provideWindows/Linux/OSXmulti-platformSDK;Support nativeC/C++, C#/VB.Net, Directshow, Twain API;

    Imaging system model

    Sensor model and size

    pixel(μm)

    GPhotosensitivity

    dark current

    FPS/resolution

    Sample Average

    time of exposure

    E3CSONY12M

    12M/IMX226(C)
    1/1.7“(7.40x5.55)

    1.85x1.85

    280mvwith 1/30s
    0.
    1mv with 1/30s

    25@4000x3000
    50@2048x1080

    1x1

    2x2

    0.1ms~15s

    hardware configuration

    Spectral response range

    380-650nm (In the presence of an infrared cut-off filter)

    white balance

    ROIwhite balance/hand movementTemp-Tintadjust

    Color restoration technology

    Ultra-FineTMhardwareISPVideo processing engine

    Capture and ControlAPI

    Native C/C++, C#/VB.Net, DirectShow, TwainandLabview

    Record Mode

    Images and videos

    Cooling method*

    natural cooling

    Camera working environment

    Working temperature (Celsius)

    -10~ 50

    Storage temperature (Celsius)

    -20~ 60

    Working humidity

    30~80%RH

    Storage humidity

    10~60%RH

    power supply

    The camera passes throughUSBInterface power supply

    Software operating environment

    operating system

    Microsoft®Windows®XP/ Vista / 7 / 8 /10(32 & 64position)

    computer configuration

    CPU:Intel Core 2 2.8GHzor higher

    Memory:2GBOr larger

    USBinterface: USB3.0High speed interface orUSB2.0interface

  • Online inquiry
    • Contacts
    • Company
    • Telephone
    • Email
    • WeChat
    • Verification Code
    • Message Content

    Successful operation!

    Successful operation!

    Successful operation!