YSZ-150B series pointer pressure transmitterMainly used for measuring pressure and negative pressure data of non crystalline and non solidified fluid media. The transmitter uses imported diffusion or ceramic sensors as pressure electricity conversion elements. As the input pressure changes, the output voltage of the sensor also changes linearly. After precise circuit amplification, the voltage is converted into a 4-20mA (DC) standard output signal; In order to send the measured values to the control room over a long distance and achieve automatic control and detection of the production process. This instrument has a pointer type on-site indication function, which can indicate the system pressure normally in the event of a power outage for on-site process testing. This gauge is also an ideal replacement for differential remote pressure gauges. |
|
|
|
Main technical indicators
|
| model |
YSZ-150B |
| accuracy class |
On site instruction: Level 1.6; Output signal: 0.2 level, 0.5 level |
| measurement range |
0~0.4 to 60MPa, -0.1~0MPa, -0.1~0.06 to 2.4MPa |
| output signal |
2-wire system: 4~20mA (sensor working voltage: 24V. DC) |
| Adaptation temperature |
-20~+70°C |
| material |
Shell: SUS304, Pressure System: SUS304, SUS316 |
| category |
通用型、防腐性 |
|
|
|
Overall dimensions
|
|
| YSZ-150B |
|
|
Ordering Instructions
|
| When placing an order, please specify the instrument model, range, accuracy level, output signal, material requirements, etc |
|