HI1332P Fillable dual dialysis membrane plastic composite acidity pH electrode |
|
Suitable for sample measurement in conventional laboratories, on-site, field chemical reagents, quality control, etc | |
scope of application:0 to 13 pH; Sample temperature: 0 to 70 ° C (32 to 158 ° F),Sensor type:sphere【Ø7.5mm】 | |
Electrode characteristics:Dual reference【Ag/AgCl】The,oneCeramic dialysis membrane【15-20 μL/h】;Type of filling fluid:3.5 M KCI【recommendHI7082】 | |
Maximum pressure:0.1bar;interface type:BNC+PINinterface,1Rice noodle length,Electrode material: PEI,Electrode size:120mm ר12mm | |
Acidity electrode maintenance, upkeep, and preservation plan | |
![]() |
HI70300 Customized specialized electrode preservation solution Specially formulated with high-purity chemical reagents and high-quality deionized water, rigorously certified with various measuring tools and containers, carefully formulated in a temperature and humidity environment that meets the requirements, and traceableNISTstandard reference materials(SRM); Hanna brand electrode preservation solution, formulated with a special formula to minimize bacterial growth on the electrode, adopts a unique tamper proof sealing setting to ensure the quality and freshness of the electrode preservation solution, If the acidity electrode glass sensing membrane or dialysis membrane head is found to be dry, the electrode should be soaked inHI70300At least in the electrode preservation solution1More than an hour. |
![]() |
After using the electrode, it is necessary to immediately use a specialized cleaning solution, which is an indispensable step to ensure the service life and response time of the electrode. According to the different samples being measured, the corresponding electrode cleaning solution should be selected: |
![]() |
It is necessary to regularly and timely replace the electrode filling electrolyte for the fillable electrode series. If the electrode electrolyte is contaminated or left for a long time, it will precipitate and block the dialysis membrane, making cleaning difficult and affecting the electrode response time, measurement accuracy, and service life. Therefore, it is recommended that users use electrodes that are frequently used1-2It is also recommended to replace the electrolyte of electrodes that are not frequently used once a month6Replace the electrolyte once a month. |
![]() |
When using a new electrode, the top should be removed firstHI740200Protect the cover and inspect the entire electrode. If salt crystals are formed in the electrode tip and protective cover due to the evaporation of electrolyte inside the electrode through the dialysis membrane, it does not affect the normal use of the electrode, indicating that the electrode dialysis membrane is normal. Rinse it off with clean water.
To ensure fast response time, the electrode glass sensing membrane and dialysis membrane should be kept moist at all times. After measurement or calibration is completed, the electrode should be cleaned correctly and thenHI740200Add electrode protection sleeveHI70300Electrode preservation solution up to the scale line |