VIP member
PD power frequency inverter
Product features Pure sine wave output Pure sine wave output
Product details
|
Pure sine wave output, able to meet the electricity needs of most electrical appliances, with high conversion efficiency and low noise |
![]() Power frequency toroidal transformer Low power consumption, high efficiency,strongLoad capacity and impact resistance, good stability |
![]() simple design PD inverters avoid tedious electronic circuit design, with clear and concise structural layout, easy maintenance, and durability |
|
Priority given to mains power, priority given to batteries, energy-saving mode |
LCD/LCD+LED display, supports RS232 communication interface, real-time display and remote monitoring of machine working status |
Battery undervoltage alarm protection, overload power protection, temperature protection |
| Technical Specifications | ||||||||
| 型号 PD | 35112 | 50112 | 10224 | 10212 | 15212/24 | 20224/48 | 30224/48 | |
| rated power | 350W | 500W | 1000W | 1000W | 1500W | 2000W | 3000W | |
| Standard battery voltage | 12VDC | 12VDC | 24VDC | 12VDC | 12/24VDC | 24/48VDC | 24/48VDC | |
| Machine size (L * W * Hmm) | 310*240*115 | 360*210*380 | ||||||
| Packaging size (L * W * Hmm) | 370*320*200 | 420*280*445 | ||||||
| Net weight (kg) | 5 | 6 | 8 | 13 | 14 | 16 | 20 | |
| 毛重量(kg) | 6 | 7 | 9 | 14 | 15 | 17 | 21 | |
| General Parameters | ||||||||
| input | DC input voltage range | 10.5VDC-15VDC (single battery voltage) | ||||||
| Range of mains input voltage | 73~138VAC/145~275VAC | 85~138VAC/170~275VAC | ||||||
| Frequency range of mains power input | 45HZ-65HZ | |||||||
| output | Inverter output efficiency | ≥85% | ||||||
| Inverter output voltage | 110VAC±2% / 220VAC±2% | |||||||
| Inverter output frequency | 50/60HZ±1% | |||||||
| Inverted output waveform | pure sine wave | |||||||
| Output voltage range of mains power | 110VAC±10% / 220VAC±10% | |||||||
| Frequency range of mains power output | automatic tracking | |||||||
| protect | Battery undervoltage alarm | 10.5VDC (single battery voltage) | ||||||
| Battery undervoltage protection | 10VDC (voltage of a single battery) | |||||||
| Battery overvoltage protection | 17V ± 0.5V (voltage of a single battery) | |||||||
| Voltage overvoltage alarm | 15VDC-16VDC (single battery voltage) | |||||||
| Overload power protection | Rated power above 110% | |||||||
| Temperature protection | Alarm at ≥ 85 ℃, shut down the entire machine at ≥ 90 ℃ | |||||||
| Convert time | ≤4ms | |||||||
| Battery Type | Select according to customer requirements | |||||||
| panel display | LCD | |||||||
| cooling method | Smart Fan Control | |||||||
| Charging current of mains power | Maximum 15A | |||||||
| Working mode (freely selectable) | 1. Normal mode (mains priority, mains charging, backup power UPS) | |||||||
| 2 energy-saving modes (turn off the machine when the load power is ≤ 10%, turn on when it is ≥ 11% -100%. Power saving: achieve unmanned operation) | ||||||||
| 3. Inverter priority (during charging: when the battery voltage is ≥ 13V, convert to inverter; When reversing: When the battery voltage is ≤ 10.5V, enter the mains power state and fully and reasonably utilize solar energy | ||||||||
| communication | RS232 (optional) | |||||||
| environment | temperature | -10℃~40℃ | ||||||
| relative humidity | 0%~95%, no condensation | |||||||
| Note: Please contact the sales consultant to obtain the latest product specifications | ||||||||