VIP member
PCR-LE2 AC power supply
Wide output range can also be used for DC output. Rated voltage (AC): 1-300V. Rated frequency: 1-999.9Hz. Rated voltage (DC): ± 1.4~± 424V. In additio
Product details
Product Features
-
Wide output range can also be DC output
- Rated output voltage (AC): 1-300V
- Rated output frequency: 1~999.9Hz
- Rated output voltage (DC): ± 1.4 to ± 424V
-
Response Options
According to the load conditions and usage, the response (response speed) of the internal amplifier system can be selected.- Typical speed (MEDIUM): in various power environment tests
- High Stability (SLOW): Used in EMC testing sites for supply, etc
-
Simulate abnormal power cord
When used in AC mode, the abnormality of the power line can be simulated by stopping the output of the PCR-LE2 series, voltage dip, and voltage pop. Can be used for testing rectifier power supplies and electronic instruments.
-
Various measurement functions
The actual effective voltage/current, peak voltage/current, effective power/apparent power, and power factor that can be measured output. Can analyze the high-order harmonics of the output current (up to 40 times).
-
Timing function
The output voltage/frequency/waveform can vary over time and can automatically perform power environment tests. In addition to AC output, it can also achieve timing for DC output and AC+DC output. It can set a resolution of 0.1ms and is equipped with initial phase setting, phase transition, jump function, and pause function.
-
Sensor detection, voltage compensation adjustment
Even if the device is located far away from the load instrument, it can compensate for voltage drop and stabilize the voltage (effective value) at the load end. In sensor detection, there are hardware sensor detection and software sensor detection. It can be used differently according to load conditions and usage purposes.
-
Output current control
By utilizing the optional (time, continuous) trip current limiting function, the output current (actual effective value) can be stably controlled to achieve continuous operation action. Under stable conditions of power facilities (distribution panels, circuit breakers, wiring facilities, etc.), power on tests can be conducted.
-
Energy saving function (power-saving function)
- sleep function
After a certain period of no output, the power unit will enter a sleep state, which can suppress power consumption. -
Energy saving operation function
The energy-saving operation function can be utilized to provide only the power required by the load according to its size.
- sleep function
-
external communication
RS232C (standard). Through optional components, remote control can be achieved using GPIB, USB, LAN. Due to LAN support for LXI specifications, a cost-effective system architecture can be obtained.
-
Storage function
The host memory can store a total of 99 waveform libraries * *, including output frequency, voltage (AC/DC), and waveform data for one cycle.
In addition, the contents of the host memory, panel settings, simulation of power cord abnormalities, and timing data can be saved on the USB memory.
-
Supported Standards
Can be used for IEC61000-3 and 4 series standard testing systems. The optional items also include application software. Please refer to the end of the volume for detailed information.
-
Remote control front panel
The front panel can be removed for use. It can be used as a remote control through the control panel extension cable of the optional component (EC05-PCR).
-
System connection test accompanied by reverse current
According to the system networking technology requirements policy
-
Excellent maintenance performance achieved through unit structure
The PCR-LE2 series is a unit structure. The power unit can be maintained (replaced, etc.) using 1kVA units.
-
Other functions
- Set output impedance
- Measure high-order harmonics
- Software startup (control rise time)
- Fixed internal VCC
lineup
model | specifications |
---|---|
PCR6000LE2 | Single phase 6kVA/Single phase 3-wire 4kVA/Three phase 6kVA/, AC 1~300V, 1~999.9Hz, DC+/-1.4~+/-424V, supports external signal input, can be used as power amplifier action |
PCR9000LE2 | Single phase 9kVA/Single phase 3-wire 6kVA/Three phase 9kVA/, AC 1~300V, 1~999.9Hz, DC+/-1.4~+/-424V, supports external signal input, can be used as power amplifier action |
PCR27000LE2 | Single phase 27kVA/Single phase 3-wire 18kVA/Three phase 27kVA/AC 1~300V, 1~999.9Hz, DC+/-1.4~+/-424V, supports external signal input, can be used as power amplifier action |
Optional parts (associated products)
IB05-PCR-LE
gpib interface
GPIB interface is used for the PCR-LE series
GPIB interface is used for the PCR-LE series
US05-PCR-LE
USB interface
USB interface for the PCR-LE series
USB interface for the PCR-LE series
LN05-PCR-LE
LAN interface
LAN interface for the PCR-LE series
LAN interface for the PCR-LE series
EX05-PCR-LE
External signal input interface
External signal input interface for PCR-LE (amplified output waveform input)
External signal input interface for PCR-LE (amplified output waveform input)
EX06-PCR-LE
^External signal input interface
PCR-LE uses an external signal input interface (to change the voltage value of the AC output based on the DC signal)
PCR-LE uses an external signal input interface (to change the voltage value of the AC output based on the DC signal)
SD009-PCR-LE
Software for power cord immunity test
SD009-PCR-LE (Quick Immunity Sequencer 2) is an essential application software for conducting anti-interference tests in accordance with the EMC standard requirements for power line interference standards (IEC61000-4 series) using our company's multi-functional AC power supply PCR-LE series. In addition to being used for testing that meets the latest standard requirements or a portion of preliminary testing, it is also possible to expand the set test conditions for pre-approval testing during the development phase, as well as for anti-interference margin tolerance testing.
*Note: In order to use this software, you will need at least 2.0 firmware version of PCR-LE.
SD009-PCR-LE (Quick Immunity Sequencer 2) is an essential application software for conducting anti-interference tests in accordance with the EMC standard requirements for power line interference standards (IEC61000-4 series) using our company's multi-functional AC power supply PCR-LE series. In addition to being used for testing that meets the latest standard requirements or a portion of preliminary testing, it is also possible to expand the set test conditions for pre-approval testing during the development phase, as well as for anti-interference margin tolerance testing.
*Note: In order to use this software, you will need at least 2.0 firmware version of PCR-LE.
SD012-PCR-LE -NEW-
Software for testing aviation electronic equipment
Avionics Test Software "SD012-PC-LE" is an application software that controls the high-performance AC stable power supply of the PCR-LE/LE2 series produced by our company and supports aircraft testing standards. The supported testing standards include military aircraft testing standard MIL-STD-704 and civilian aircraft testing standards RTCA/DO-160 and JIS W0812. Because the testing method is set as a library, it is easy to conduct testing by only selecting the connection method and testing method.
*Note: In order to use this software, you will need at least firmware version 4.2 of PCR-LE/LE2.
Avionics Test Software "SD012-PC-LE" is an application software that controls the high-performance AC stable power supply of the PCR-LE/LE2 series produced by our company and supports aircraft testing standards. The supported testing standards include military aircraft testing standard MIL-STD-704 and civilian aircraft testing standards RTCA/DO-160 and JIS W0812. Because the testing method is set as a library, it is easy to conduct testing by only selecting the connection method and testing method.
*Note: In order to use this software, you will need at least firmware version 4.2 of PCR-LE/LE2.
AC14-1P3M-M8C-3S
Input power cord
Single core, 3 pieces 3 m 14 mm2M8 (for PCR3000LE/6000LE/6000LE2)
Single core, 3 pieces 3 m 14 mm2M8 (for PCR3000LE/6000LE/6000LE2)
AC14-1P3M-M5C-4S
Input power cord
Single core, 4 pieces 3 m 14 mm2M5 (for PCR9000LE/9000LE2)
Single core, 4 pieces 3 m 14 mm2M5 (for PCR9000LE/9000LE2)
EC05-PCR
Control panel extension cable
Control panel extension cable for 2 meters in the PCR-LE series
Control panel extension cable for 2 meters in the PCR-LE series
PRODUCT FUNCTION
The PCR-LE2 series is based on the PCR-LE series and can switch between single-phase output/single-phase 3-wire output/three-phase output modes of the same capacity through panel operation with a single host.
Concentrating the same basic performance as the PCR-LE series, and implementing a common power unit with the PCR-LE series, it is easier to operate compared to individual systems such as single-phase/single-phase 3-wire/three-phase, and is conducive to the effective use of space. There are three models: 6kVA, 9kVA, and 27kVA.
Concentrating the same basic performance as the PCR-LE series, and implementing a common power unit with the PCR-LE series, it is easier to operate compared to individual systems such as single-phase/single-phase 3-wire/three-phase, and is conducive to the effective use of space. There are three models: 6kVA, 9kVA, and 27kVA.