Model Meaning
Product Introduction
PBG vertical shielded pipeline pump has absorbed advanced technology in the design and manufacturing of shielded pipeline pumps internationally, and applied the shielding technology of motors to the field of liquid transportation. It is a series of new products launched to meet the needs of the domestic market.
The performance parameters of PBG vertical clear water pipeline shielded pump series basically comply with the provisions of international standard ISO2858 and national standard JB/T6878.2-93. It has significant characteristics such as design specifications, high universality, reasonable structure, stable performance, low noise operation, and no vibration, making it an ideal product to replace conventional horizontal centrifugal pumps and vertical pipeline pumps. The series performance parameters basically comply with the provisions of international standard ISO2858 and national standard JB/T6878.2-93.
There are a total of 67 varieties and 184 specifications in the entire series, with a performance range of 6.3~108m3/h flow rate, 12.5~125m head, equipped with a motor power of 0.37~160KW, and speeds of 1450r/min and 2900r/min.
Product Features
1. The pump structure is compact, the machine pump is integrated, and the volume is small. Its vertical structure has a small installation footprint, balanced operation, and no need for adjustment during installation.
2. The inlet and outlet of the pump are designed with flanges of the same specifications and located on the same centerline. They can be directly installed on the pipeline like valves, and the center is low for easy pipeline layout, making installation particularly convenient.
3. The pump is coaxial with the motor, with a short axial dimension, making the pump run more smoothly and with low noise.
4. Cancelling the traditional shaft seal method avoids the leakage of the conveying medium, thus having the significant feature of completely no leakage.
5. Replacing conventional motor rolling bearings with sliding bearings enables the pump to operate smoothly with extremely low vibration and noise.
6. Easy to install and repair bolts, no need to disassemble the piping system. Simply remove the connecting nut to extract all rotor components for inspection and maintenance.
7. The series and parallel operation of the pump can be carried out according to the requirements of flow rate and head.
application
1. PBG vertical clear water pipeline shielded pump is a common type used for transporting clear water and other liquids with physical and chemical properties similar to clear water. The medium is suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance transportation, HVAC refrigeration cycle, bathroom and other cold and warm water circulation pressurization and equipment matching, with a temperature not exceeding 80 ℃. Especially suitable for occasions with high requirements for vibration and noise, such as underground pump rooms, air conditioning refrigeration systems, etc.
2. PBG vertical clear water pipeline shielded pump hot water type is mainly used for conveying soft water with a temperature not exceeding 160 degrees Celsius and no solid particles. It is suitable for energy, metallurgy, chemical, textile, papermaking, hotels, restaurants, bathrooms, boiler hot water pressurized circulation transportation, urban heating system circulation and other fields.
3. The PBG vertical clear water pipeline shielded pump is an anti-corrosion type for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for industries such as petroleum, chemical, metallurgy, power, papermaking, food, pharmaceuticals, and synthetic fibers.
Conditions of Use
1. The medium must be a fluid that is soft water, thin, non solidifying, non flammable, and free of solid particles and fibers.
2. The medium temperature is 80 ℃ for ordinary type and 16080 ℃ for hot water type.
3. In general, the working pressure of the system should not exceed 1.2MPa, and the inlet pressure should not be less than 0.5MPa. In special circumstances, please contact our factory in advance.
4. The ambient temperature shall not exceed 40 ℃ and the relative humidity shall not exceed 95%.
STRUCTURE DESCRIPTION
The pump is a machine pump integrated structure, mainly composed of pump body, impeller, connecting body, sliding bearings, stator, rotor, shielding sleeve, motor housing and other components. The pump is a vertical single-stage single suction centrifugal pump, with the inlet and outlet on the same horizontal axis and the same diameter specifications. It can be directly installed on any part of the pipeline like a valve, making loading and unloading extremely convenient and occupying less space. The pump is integrated with the motor through a connecting body, and the bearings are made of imported graphite impregnated resin composite bearings. The motor stator and rotor are isolated by shielding sleeves. The bearing uses liquid as the lubricant and coolant, which has the characteristics of reasonable design and reliable operation. The pump is equipped with a base and can be directly installed on the foundation. Due to its low noise and vibration free characteristics, there is no need to install vibration isolators or pads during installation.
Structure diagram
![]() |
name |
material |
Serial Number |
name |
1 |
pump body |
10 |
stator can |
|
2 |
Sealing ring |
11 |
Upper bearing seat |
|
3 |
impeller |
12 |
Rotor end cover |
|
4 |
Lower bearing seat |
13 |
stator can |
|
5 |
Motor junction box |
14 |
bearing |
|
6 |
motor housing |
15 |
pump cover |
|
7 |
bearing |
16 |
Cooling water pipe components |
|
8 |
stator assembly |
17 |
axle |
|
9 |
rotor assembly |
Spectrogram
![]() |
performance parameter
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
20-110 |
20 |
1.8 2.5 3.3 |
0.5 0.69 0.91 |
16 15 13.5 |
25 34 35 |
2800 |
0.37 |
2.3 |
25 |
20-160 |
20 |
1.8 2.5 3.3 |
0.5 0.69 0.91 |
33 32 30 |
19 25 23 |
2900 |
0.75 |
2.3 |
29 |
25-110 |
25 |
2.8 4 5.2 |
0.78 1.11 1.44 |
16 15 13.5 |
34 42 41 |
2900 |
0.55 |
2.3 |
26 |
25-125 |
25 |
2.8 4 5.2 |
0.78 1.11 1.44 |
20.6 20 18 |
28 36 35 |
2900 |
0.75 |
2.3 |
28 |
25-125A |
25 |
2.5 3.6 4.6 |
0.69 1.0 1.28 |
17 16 14.4 |
35 |
2900 |
0.55 |
2.3 |
27 |
25-160 |
25 |
2.8 4 5.2 |
0.78 1.11 1.44 |
33 32 30 |
24 32 33 |
2900 |
1.5 |
2.3 |
39 |
25-160A |
25 |
2.6 3.7 4.9 |
0.12 1.03 1.36 |
29 28 26 |
31 |
2900 |
1.1 |
2.3 |
34 |
32-100 |
32 |
3.5 5 6.5 |
0.97 0.39 1.8 |
13.2 12.5 11.3 |
40 44 42 |
2900 |
0.75 |
2.3 |
28 |
32-125 |
32 |
3.5 5 6.5 |
0.97 0.39 1.8 |
22 20 18 |
40 44 42 |
2900 |
0.75 |
2.3 |
28 |
32-125A |
32 |
3.1 4.5 5.8 |
0.86 1.25 1.61 |
17.6 16 14.4 |
43 |
2900 |
0.75 |
2.3 |
28 |
32-160 |
32 |
3.5 5 6.5 |
0.97 0.39 1.8 |
33.2 32 30.2 |
48 54 53 |
2900 |
1.5 |
2.0 |
39 |
32-160A |
32 |
3.1 4.5 5.8 |
0.86 1.25 1.61 |
29 28 26.3 |
48 54 53 |
2900 |
1.1 |
2.0 |
39 |
32-200 |
32 |
3.5 5 6.5 |
0.97 0.39 1.8 |
50.5 50 48 |
34 40 42 |
2900 |
3 |
2.0 |
77 |
32-200A |
32 |
2.8 4 5.2 |
0.78 1.11 1.44 |
44.6 44 42.7 |
34 40 42 |
2900 |
2.2 |
2.0 |
74 |
32-100(I) |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
13.2 12.5 11.3 |
48 54 53 |
2900 |
0.75 |
2.0 |
32 |
32-100(I)A |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
13.2 12.5 11.3 |
48 54 53 |
2900 |
0.75 |
2.0 |
32 |
32-125(I) |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
22 20 18 |
48 54 53 |
2900 |
1.1 |
2.3 |
34 |
32-125(I)A |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
17.6 16 14.4 |
40 45 41 |
2900 |
0.75 |
2.3 |
33 |
32-160(I) |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
33.2 32 30.2 |
34 40 42 |
2900 |
2.2 |
2.0 |
47 |
32-160(I)A |
32 |
4.1 5.9 7.8 |
1.14 1.64 2.17 |
29 28 26.3 |
34 39 39 |
2900 |
1.5 |
2.3 |
43 |
32-160(I)B |
32 |
3.8 5.5 7.2 |
1.06 1.53 2.0 |
25.5 24 22.5 |
34 38 37 |
2900 |
1.1 |
2.3 |
38 |
32-200(I) |
32 |
4.4 6.3 8.3 |
1.22 1.75 2.32 |
50.5 50 48 |
26 33 35 |
2900 |
4 |
2.0 |
43 |
32-200(I)A |
32 |
4.1 5.9 7.8 |
1.14 1.64 2.17 |
45 44 42 |
26 31 30 |
2900 |
3 |
2.3 |
62 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
40-100 |
40 |
4.4 6.3 8.3 |
1.22 1.75 2.31 |
13.2 12.5 11.3 |
48 54 53 |
2900 |
0.55 |
2.3 |
32 |
40-100A |
40 |
3.9 5.6 7.4 |
1.08 1.56 2.06 |
10.6 10 9 |
52 |
2900 |
0.37 |
2.3 |
32 |
40-125 |
40 |
4.4 6.3 8.3 |
1.22 1.75 2.31 |
21 20 18 |
41 46 43 |
2900 |
1.1 |
2.3 |
34 |
40-125A |
40 |
3.9 5.6 7.4 |
1.08 1.56 2.06 |
17.6 16 14.4 |
40 45 41 |
2900 |
0.75 |
2.3 |
33 |
40-160 |
40 |
4.4 6.3 8.3 |
1.22 1.75 2.31 |
33 32 30 |
35 40 40 |
2900 |
2.2 |
2.3 |
47 |
40-160A |
40 |
4.1 5.9 7.8 |
1.14 1.64 2.17 |
29 28 26.3 |
34 39 39 |
2900 |
1.5 |
2.3 |
43 |
40-160B |
40 |
3.8 5.5 7.2 |
1.06 1.53 2.0 |
25.5 24 22.5 |
34 38 37 |
2900 |
1.1 |
2.3 |
38 |
40-200 |
40 |
4.4 6.3 8.3 |
1.22 1.75 2.31 |
51 50 48 |
26 33 32 |
2900 |
4 |
2.3 |
74 |
40-200A |
40 |
4.1 5.9 7.8 |
1.14 1.64 2.17 |
45 44 42 |
26 31 30 |
2900 |
3 |
2.3 |
62 |
40-200B |
40 |
3.7 5.3 7.0 |
1.03 1.47 1.94 |
38 36 34.5 |
29 |
2900 |
2.2 |
2.3 |
52 |
40-250 |
40 |
4.4 6.3 8.3 |
1.22 1.75 2.31 |
82 80 74 |
24 28 28 |
2900 |
7.5 |
2.3 |
105 |
40-250A |
40 |
4.1 5.9 7.8 |
1.14 1.64 2.17 |
72 70 65 |
24 28 27 |
2900 |
5.5 |
2.3 |
98 |
40-250B |
40 |
3.8 5.5 7.0 |
1.06 1.53 1.94 |
61.5 60 56 |
23 27 26 |
2900 |
4 |
2.3 |
77 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
40-100(I) |
40 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
13.2 12.5 11.3 |
55 62 60 |
2900 |
1.1 |
2.3 |
34 |
40-100(I)A |
40 |
8 11 14.5 |
2.22 3.05 4.03 |
10.6 10 9 |
60 |
2900 |
0.75 |
2.3 |
32 |
40-125(I) |
40 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
21.2 20 17.8 |
49 58 57 |
2900 |
1.5 |
2.3 |
38 |
40-125(I)A |
40 |
8 11 14.5 |
2.22 3.05 4.03 |
17 16 14 |
57 |
2900 |
1.1 |
2.3 |
33 |
40-160(I) |
40 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
33 32 30 |
45 52 51 |
2900 |
3 |
2.3 |
56 |
40-160(I)A |
40 |
8.2 11.7 15.2 |
2.28 3.25 4.22 |
29 28 26 |
44 51 50 |
2900 |
2.2 |
2.3 |
47 |
40-160(I)B |
40 |
7.3 10.4 13.5 |
2.38 2.89 3.75 |
23 22 20.5 |
50 |
2900 |
1.5 |
2.3 |
43 |
40-200(I) |
40 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
51.2 50 48 |
38 46 46 |
2900 |
5.5 |
2.3 |
85 |
40-200(I)A |
40 |
8.3 11.7 15.3 |
2.31 3.25 4.25 |
45.0 44 42 |
37 45 45 |
2900 |
4 |
2.3 |
75 |
40-200(I)B |
40 |
7.5 10.6 13.8 |
2.08 2.94 3.83 |
37 36 34 |
44 |
2900 |
3 |
2.3 |
63 |
40-250(I) |
40 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
81.2 80 77.5 |
31 38 40 |
2900 |
11 |
2.3 |
145 |
40-250(I)A |
40 |
8.2 11.6 15.2 |
2.28 3.22 4.22 |
71.0 70 68 |
38 |
2900 |
7.5 |
2.3 |
95 |
40-250(I)B |
40 |
7.6 10.8 14 |
2.11 3.0 3.89 |
61.4 60 58 |
37 |
2900 |
7.5 |
2.3 |
94 |
40-250(I)C |
40 |
7.1 10.0 13.1 |
1.97 2.78 3.64 |
53.2 52 50.4 |
36 |
2900 |
5.5 |
2.3 |
88 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
50-100 |
50 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
13.6 12.5 11.3 |
55 62 60 |
2900 |
1.1 |
2.3 |
36 |
50-100A |
50 |
8 11 14.5 |
2.22 3.05 4.03 |
11 10 9 |
60 |
2900 |
0.75 |
2.3 |
35 |
50-125 |
50 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
21.5 20 17.8 |
49 58 57 |
2900 |
1.5 |
2.3 |
43 |
50-125A |
50 |
8 11 14.5 |
2.22 3.05 4.03 |
17 16 14 |
57 |
2900 |
1.1 |
2.3 |
38 |
50-160 |
50 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
33 32 30 |
45 52 51 |
2900 |
3 |
2.3 |
59 |
50-160A |
50 |
8.2 11.7 15.2 |
2.28 3.25 4.22 |
29 28 26 |
44 51 50 |
2900 |
2.2 |
2.3 |
51 |
50-160B |
50 |
7.3 10.4 13.5 |
2.38 2.89 3.75 |
23 22 20.5 |
50 |
2900 |
1.5 |
2.3 |
47 |
50-200 |
50 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
52 50 48 |
38 46 46 |
2900 |
5.5 |
2.3 |
101 |
50-200A |
50 |
8.3 11.7 15.3 |
2.31 3.25 4.25 |
45.8 44 42 |
37 45 45 |
2900 |
4 |
2.3 |
80 |
50-200B |
50 |
7.5 10.6 13.8 |
2.08 2.94 3.83 |
37 36 34 |
44 |
2900 |
3 |
2.3 |
68 |
50-250 |
50 |
8.8 12.5 16.3 |
2.44 3.47 4.53 |
82 80 77.5 |
29 38 40 |
2900 |
11 |
2.3 |
160 |
50-250A |
50 |
8.2 11.6 15.2 |
2.28 3.22 4.22 |
71.5 70 68 |
38 |
2900 |
7.5 |
2.3 |
115 |
50-250B |
50 |
7.6 10.8 14 |
2.11 3.0 3.89 |
61.4 60 58 |
37 |
2900 |
7.5 |
2.3 |
114 |
50-250C |
50 |
7.1 10.0 13.1 |
1.97 2.78 3.64 |
53.2 52 50.4 |
36 |
2900 |
5.5 |
2.3 |
108 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
50-100(I) |
50 |
17.5 25 32.5 |
4.86 6.94 9.03 |
13.7 12.5 10.5 |
67 69 69 |
2900 |
1.5 |
2.5 |
41 |
50-100(I)A |
50 |
15.6 22.3 29 |
4.3 6.19 8.1 |
11 10 8.4 |
65 67 68 |
2900 |
1.1 |
2.5 |
36 |
50-125(I) |
50 |
17.5 25 32.5 |
4.86 6.94 9.03 |
21.5 20 18 |
60 68 67 |
2900 |
3 |
2.5 |
56 |
50-125(I)A |
50 |
15.6 22.3 29 |
4.33 6.19 8.1 |
17 16 13.6 |
58 66 65 |
2900 |
2.2 |
2.5 |
48 |
50-160(I) |
50 |
17.5 25 32.5 |
4.68 6.94 9.03 |
34.4 32 27.5 |
54 63 60 |
2900 |
4 |
2.5 |
72 |
50-160(I)A |
50 |
16.4 23.4 30.4 |
4.56 6.5 8.44 |
30 28 24 |
54 62 59 |
2900 |
4 |
2.5 |
71 |
50-160(I)B |
50 |
15.0 21.6 28 |
4.17 6.0 7.78 |
26 24 20.6 |
58 |
2900 |
3 |
2.5 |
59 |
50-200(I) |
50 |
17.5 25 32.5 |
4.86 6.94 9.03 |
52.7 50 45.5 |
49 58 59 |
2900 |
7.5 |
2.5 |
108 |
50-200(I)A |
50 |
16.4 23.5 30.5 |
4.56 6.53 8.47 |
46.4 44 40 |
48 57 58 |
2900 |
7.5 |
2.5 |
107 |
50-200(I)B |
50 |
15.2 21.8 28.3 |
4.22 6.06 7.86 |
40 38 34.5 |
55 |
2900 |
5.5 |
2.5 |
100 |
50-250(I) |
50 |
17.5 25 32.5 |
4.86 6.94 9.03 |
82 80 76.5 |
39 50 52 |
2900 |
15 |
2.5 |
175 |
50-250(I)A |
50 |
16.4 23.4 30.5 |
4.56 6.5 8.47 |
71.5 70 67 |
39 50 52 |
2900 |
11 |
2.5 |
165 |
50-250(I)B |
50 |
15 21.6 28 |
4.17 6.0 7.78 |
61 60 57.4 |
38 49 54 |
2900 |
11 |
2.5 |
165 |
50-315(I) |
50 |
17.5 25 32.5 |
4.86 6.94 9.03 |
128 125 122 |
30 40 44 |
2900 |
30 |
2.5 |
310 |
50-315(I)A |
50 |
16.6 23.7 31 |
4.61 6.58 8.6 |
115 113 110 |
30 40 44 |
2900 |
22 |
2.5 |
245 |
50-315(I)B |
50 |
15.7 22.5 29.2 |
4.36 6.25 8.0 |
103 101 98 |
39 |
2900 |
18.5 |
2.5 |
215 |
50-315(I)C |
50 |
14.4 20.6 26.8 |
4.0 5.72 7.44 |
86 85 83 |
38 |
2900 |
15 |
2.5 |
195 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
65-100 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
13.7 12.5 10.5 |
67 69 69 |
2900 |
1.5 |
2.5 |
46 |
65-100A |
65 |
15.6 22.3 29 |
4.3 6.19 8.1 |
11 10 8.4 |
65 67 68 |
2900 |
1.1 |
2.5 |
41 |
65-125 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
21.5 20 18 |
60 68 67 |
2900 |
3 |
2.5 |
58 |
65-125A |
65 |
15.6 22.3 29 |
4.33 6.19 8.1 |
17 16 14.4 |
58 66 65 |
2900 |
2.2 |
2.5 |
49 |
65-160 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
34.4 32 27.5 |
54 63 60 |
2900 |
4 |
2.5 |
75 |
65-160A |
65 |
16.4 23.4 30.4 |
4.56 6.5 8.44 |
30 28 24 |
54 62 59 |
2900 |
4 |
2.5 |
75 |
65-160B |
65 |
15.0 21.6 28 |
4.17 6.0 7.78 |
26 24 20.6 |
58 |
2900 |
3 |
2.5 |
63 |
65-200 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
52.7 50 45.5 |
49 58 59 |
2900 |
7.5 |
2.5 |
107 |
65-200A |
65 |
16.4 23.5 30.5 |
4.56 6.53 8.47 |
46.4 44 40 |
48 57 58 |
2900 |
7.5 |
2.5 |
107 |
65-200B |
65 |
15.2 21.8 28.3 |
4.22 6.06 7.86 |
40 38 34.5 |
55 |
2900 |
5.5 |
2.5 |
100 |
65-250 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
82 80 76.5 |
39 50 52 |
2900 |
15 |
2.5 |
180 |
65-250A |
65 |
16.4 23.4 30.5 |
4.56 6.5 8.47 |
71.5 70 67 |
39 50 52 |
2900 |
11 |
2.5 |
170 |
65-250B |
65 |
15 21.6 28 |
4.17 6.0 7.78 |
61 60 57.4 |
38 49 54 |
2900 |
11 |
2.5 |
170 |
65-315 |
65 |
17.5 25 32.5 |
4.86 6.94 9.03 |
127 125 122 |
32 40 44 |
2900 |
30 |
2.5 |
320 |
65-315A |
65 |
16.6 23.7 31 |
4.61 6.58 8.6 |
115 113 110 |
32 40 44 |
2900 |
22 |
2.5 |
255 |
65-315B |
65 |
15.7 22.5 29.2 |
4.36 6.25 8.0 |
103 101 98 |
39 |
2900 |
18.5 |
2.5 |
225 |
65-315C |
65 |
14.4 20.6 26.8 |
4.0 5.72 7.44 |
86 85 83 |
38 |
2900 |
15 |
2.5 |
205 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
65-100(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
13.8 12.5 10 |
67 73 70 |
2900 |
3 |
3.0 |
63 |
65-100(I)A |
65 |
31.3 44.7 58 |
8.7 12.4 16.1 |
11 10 8 |
66 72 69 |
2900 |
2.2 |
3.0 |
53 |
65-125(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
22 20 17 |
67 72.5 70 |
2900 |
5.5 |
3.0 |
99 |
65-125(I)A |
65 |
31.3 44.7 58 |
8.7 12.5 16.1 |
17.5 16 13.6 |
66 71 69 |
2900 |
4 |
3.0 |
78 |
65-160(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
35 32 28 |
63 71 70 |
2900 |
7.5 |
3.0 |
103 |
65-160(I)A |
65 |
32.7 46.7 61 |
9.1 13.0 16.9 |
30.6 28 24 |
62 70 69 |
2900 |
7.5 |
3.0 |
103 |
65-160(I)B |
65 |
30.3 43.3 56.3 |
8.4 12.0 15.6 |
26 24 21 |
69 |
2900 |
5.5 |
3.0 |
97 |
65-200(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
53.5 50 46 |
55 67 68 |
2900 |
15 |
3.0 |
176 |
65-200(I)A |
65 |
32.8 47 61 |
9.1 13.1 16.9 |
47 44 40 |
54 66 67 |
2900 |
11 |
3.0 |
166 |
65-200(I)B |
65 |
30.5 43.5 56.6 |
8.5 12.1 15.7 |
40.6 38 33.4 |
65 |
2900 |
7.5 |
3.0 |
114 |
65-250(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
83 80 72 |
52 59 60 |
2900 |
22 |
3.0 |
235 |
65-250(I)A |
65 |
32.5 46.7 61 |
9.0 13.0 16.9 |
73 70 63 |
52 59 60 |
2900 |
18.5 |
3.0 |
205 |
65-250(I)B |
65 |
30 43.3 56 |
8.3 12.0 15.6 |
62 60 54 |
58 |
2900 |
15 |
3.0 |
180 |
65-315(I) |
65 |
35 50 65 |
9.72 13.9 18.1 |
128 125 121 |
44 54 57 |
2900 |
37 |
3.0 |
350 |
65-315(I)A |
65 |
32.5 46.5 60.5 |
9.0 12.9 16.8 |
112.6 110 106.4 |
43 54 57 |
2900 |
30 |
3.0 |
335 |
65-315(I)B |
65 |
31 44.5 58 |
8.6 12.4 16.1 |
102.5 100 98 |
53 |
2900 |
30 |
3.0 |
335 |
65-315(I)C |
65 |
29 41 53.6 |
8.1 11.4 14.9 |
87 85 83 |
51 |
2900 |
22 |
3.0 |
270 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
80-100 |
80 |
35 50 65 |
9.72 13.9 18.1 |
13.8 12.5 10 |
67 73 70 |
2900 |
3 |
3.0 |
63 |
80-100A |
80 |
31.3 44.7 58 |
8.7 12.5 16.1 |
11 10 8 |
66 72 69 |
2900 |
2.2 |
3.0 |
54 |
80-125 |
80 |
35 50 65 |
9.72 13.9 18.1 |
22 20 17 |
67 72.5 70 |
2900 |
5.5 |
3.0 |
99 |
80-125A |
80 |
31.3 45 58 |
8.7 12.5 16.1 |
17.5 16 13.6 |
66 71 69 |
2900 |
4 |
3.0 |
79 |
80-160 |
80 |
35 50 65 |
9.72 13.9 18.1 |
35 32 28 |
63 71 70 |
2900 |
7.5 |
3.0 |
105 |
80-160A |
80 |
32.7 46.7 61 |
9.1 13.0 16.9 |
30.6 28 24 |
62 70 69 |
2900 |
7.5 |
3.0 |
105 |
80-160B |
80 |
30.3 43.3 56.3 |
8.4 12.0 15.6 |
26 24 21 |
69 |
2900 |
5.5 |
3.0 |
98 |
80-200 |
80 |
35 50 65 |
9.72 13.9 18.1 |
53.5 50 46 |
55 67 68 |
2900 |
15 |
3.0 |
175 |
80-200A |
80 |
32.8 47 61 |
9.1 13.1 16.9 |
47 44 40 |
54 66 67 |
2900 |
11 |
3.0 |
165 |
80-200B |
80 |
30.5 43.5 56.6 |
8.5 12.1 15.7 |
40.6 38 33.4 |
65 |
2900 |
7.5 |
3.0 |
115 |
80-250 |
80 |
35 50 65 |
9.72 13.9 18.1 |
83 80 72 |
52 59 60 |
2900 |
22 |
3.0 |
240 |
80-250A |
80 |
32.5 46.7 61 |
9.0 13.0 16.9 |
73 70 63 |
52 59 60 |
2900 |
18.5 |
3.0 |
210 |
80-250B |
80 |
30 43.3 56 |
8.3 12.0 15.6 |
62 60 54 |
58 |
2900 |
15 |
3.0 |
185 |
80-315 |
80 |
35 50 65 |
9.72 13.9 18.1 |
128 125 122 |
43 54 57 |
2900 |
37 |
3.0 |
355 |
80-315A |
80 |
32.5 46.5 60.5 |
9.0 12.9 16.8 |
112.6 110 107.4 |
43 54 57 |
2900 |
30 |
3.0 |
340 |
80-315B |
80 |
31 44.5 58 |
8.6 12.4 16.1 |
102.5 100 98 |
53 |
2900 |
30 |
3.0 |
340 |
80-315C |
80 |
29 41 53.6 |
8.1 11.4 14.9 |
98 85 83 |
51 |
2900 |
22 |
3.0 |
275 |
80-350 |
80 |
35 50 65 |
9.72 13.9 18.1 |
146 150 142 |
55 66 67 |
2900 |
55 |
3.0 |
570 |
80-350A |
80 |
31 44.5 58 |
8.6 12.4 16.1 |
138.4 142 134.8 |
65 |
2900 |
45 |
3.0 |
470 |
80-350B |
80 |
29 41 53.6 |
8.1 11.4 14.9 |
131.4 135 127.8 |
63 |
2900 |
37 |
3.0 |
440 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
80-100(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
13.6 12.5 11 |
66 76 75 |
2900 |
5.5 |
4.5 |
108 |
80-100(I)A |
80 |
62.6 89 116 |
17.4 24.7 32.2 |
11 10 8.8 |
64 74 74 |
2900 |
4 |
4.5 |
87 |
80-125(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
23.5 20 14 |
70 76 65 |
2900 |
11 |
4.5 |
163 |
80-125(I)A |
80 |
62.6 89 116 |
17.4 24.7 32.2 |
19 16 11 |
68 74 65 |
2900 |
7.5 |
4.5 |
113 |
80-160(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
36.5 32 24 |
70 76 65 |
2900 |
15 |
4.5 |
184 |
80-160(I)A |
80 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
32 28 21 |
68 74 67 |
2900 |
11 |
4.5 |
174 |
80-160(I)B |
80 |
60.6 86.6 112.5 |
16.8 24.1 31.3 |
72 24 18 |
72 |
2900 |
11 |
4.5 |
174 |
80-200(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
54 50 42 |
65 74 73 |
2900 |
22 |
4.0 |
251 |
80-200(I)A |
80 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
47.5 44 37 |
64 73 72 |
2900 |
18.5 |
4.0 |
220 |
80-200(I)B |
80 |
61 87 113 |
16.9 24.2 31.4 |
41 38 32 |
71 |
2900 |
15 |
4.0 |
198 |
80-250(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
87 80 68 |
62 69 68 |
2900 |
37 |
4.0 |
330 |
80-250(I)A |
80 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
76 70 59.5 |
61 68 67 |
2900 |
30 |
4.0 |
315 |
80-250(I)B |
80 |
61 87 113 |
16.9 24.2 31.4 |
65 60 51 |
66 |
2900 |
30 |
4.0 |
315 |
80-315(I) |
80 |
70 100 130 |
19.4 27.8 36.1 |
132 125 114 |
55 66 67 |
2900 |
75 |
4.0 |
675 |
80-315(I)A |
80 |
66.5 95 123.6 |
18.5 26.4 34.3 |
119 113 103 |
55 66 67 |
2900 |
55 |
4.0 |
535 |
80-315(I)B |
80 |
63 90 117 |
17.5 25 32.5 |
106.6 101 92 |
65 |
2900 |
45 |
4.0 |
420 |
80-315(I)C |
80 |
58 82 107 |
16.1 22.8 29.7 |
90 85 76 |
63 |
2900 |
37 |
4.0 |
366 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
100-100 |
100 |
70 100 130 |
19.4 27.8 36.1 |
13.6 12.5 11 |
66 76 75 |
2900 |
5.5 |
4.5 |
113 |
100-100A |
100 |
62.6 89 116 |
17.4 47 32.2 |
11 10 8.8 |
64 74 74 |
2900 |
4 |
4.5 |
91 |
100-125 |
100 |
70 100 130 |
19.4 27.8 36.1 |
23.5 20 14 |
70 76 65 |
2900 |
11 |
4.5 |
169 |
100-125A |
100 |
62.6 89 116 |
17.4 24.7 32.2 |
19 16 11 |
68 74 63 |
2900 |
7.5 |
4.5 |
118 |
100-160 |
100 |
70 100 130 |
19.4 27.8 36.1 |
36.5 32 24 |
70 76 65 |
2900 |
15 |
4.5 |
191 |
100-160A |
100 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
32 28 21 |
68 74 67 |
2900 |
11 |
4.5 |
181 |
100-160B |
100 |
60.6 86.6 112.5 |
16.8 24.1 31.3 |
27 24 18 |
72 |
2900 |
11 |
4.5 |
181 |
100-200 |
100 |
70 100 130 |
19.4 27.8 36.1 |
54 50 42 |
65 74 73 |
2900 |
22 |
4.0 |
245 |
100-200A |
100 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
47.5 44 37 |
64 73 72 |
2900 |
18.5 |
4.0 |
215 |
100-200B |
100 |
61 87 113 |
16.9 24.2 31.4 |
41 38 32 |
71 |
2900 |
15 |
4.0 |
193 |
100-250 |
100 |
70 100 130 |
19.4 27.8 36.1 |
37 80 68 |
62 69 68 |
2900 |
37 |
4.0 |
345 |
100-250A |
100 |
65.4 93.5 121.6 |
18.2 26.0 33.8 |
76 70 59.5 |
61 68 67 |
2900 |
30 |
4.0 |
330 |
100-250B |
100 |
61 87 113 |
16.9 24.2 31.4 |
65 60 51 |
66 |
2900 |
30 |
4.0 |
330 |
100-315 |
100 |
70 100 130 |
19.4 27.8 36.1 |
132 125 114 |
55 66 67 |
2900 |
75 |
4.0 |
689 |
100-315A |
100 |
66.5 95 123.6 |
18.5 26.4 34.3 |
119 113 103 |
65 66 67 |
2900 |
55 |
4.0 |
549 |
100-315B |
100 |
63 90 117 |
17.5 25 32.5 |
106.6 101 92 |
65 |
2900 |
45 |
4.0 |
439 |
100-315C |
100 |
58 82 107 |
16.1 22.8 29.7 |
90 85 76 |
63 |
2900 |
37 |
4.0 |
385 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
100-100(I) |
100 |
96 160 192 |
26.7 44.4 53.3 |
14 12.5 10 |
64 73 70 |
2900 |
11 |
4.5 |
115 |
100-125(I) |
100 |
96 160 192 |
26.7 44.4 53.3 |
24 20 14 |
62 74 69 |
2900 |
15 |
4.5 |
168 |
100-125(I)A |
100 |
84 140 168 |
23.3 39 46.7 |
20 17 12 |
64 72 68 |
2900 |
11 |
4.5 |
168 |
100-160(I) |
100 |
96 160 192 |
26.7 44.4 53.3 |
36 32 27 |
69 79 75 |
2900 |
22 |
5.6 |
210 |
100-160(I)A |
100 |
84 140 168 |
23.3 39 46.7 |
32 28 23.5 |
66 76 72 |
2900 |
18.5 |
5.0 |
210 |
100-200(I) |
100 |
96 160 192 |
26.7 44.4 53.3 |
53 50 45 |
69 79 78 |
2900 |
37 |
5.2 |
402 |
100-200(I)A |
100 |
84 140 168 |
23.3 39 46.7 |
48 45 40 |
64 74 73 |
2900 |
30 |
4.5 |
395 |
100-200(I)B |
100 |
60 100 120 |
16.7 27.8 33.3 |
43 40 36 |
72 |
2900 |
22 |
4.5 |
360 |
100-250(I) |
100 |
96 160 192 |
26.7 44.4 53.3 |
83 80 72 |
65 77 74 |
2900 |
55 |
4.8 |
560 |
100-250(I)A |
100 |
84 140 168 |
23.3 39 46.7 |
75 72 65 |
60 72 69 |
2900 |
45 |
4.5 |
420 |
100-250(I)B |
100 |
60 100 120 |
16.7 27.8 33.3 |
68 65 58 |
70 |
2900 |
37 |
4.5 |
400 |
100-350 |
100 |
60 100 120 |
16.7 27.8 33.3 |
153.6 150 142 |
72 57 74 |
2900 |
90 |
4.0 |
950 |
100-350A |
100 |
61 87 113 |
16.9 24.2 31.4 |
145.6 142 134 |
75 |
2900 |
75 |
4.0 |
830 |
100-350B |
100 |
58 82 107 |
16.1 22.8 29.7 |
138.6 135 127 |
75 |
2900 |
55 |
4.0 |
600 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
125-100 |
125 |
96 160 192 |
26.7 44.4 53.3 |
13 12.5 12 |
82 |
2900 |
11 |
4.0 |
180 |
125-100A |
125 |
86 143 172 |
23.9 39.7 47.8 |
10.4 10 9.6 |
77 |
2900 |
7.5 |
4.0 |
125 |
125-125 |
125 |
96 160 192 |
26.7 44.4 53.3 |
22.6 20 17 |
80 |
2900 |
15 |
4.0 |
220 |
125-125A |
125 |
86 143 172 |
23.9 39.7 47.8 |
18 16 13.6 |
77 |
2900 |
11 |
4.0 |
210 |
125-160 |
125 |
96 160 192 |
26.7 44.4 53.3 |
36 32 28 |
78 |
2900 |
22 |
4.0 |
265 |
125-160A |
125 |
90 150 180 |
25 41.7 50 |
31.5 28 24.5 |
76 |
2900 |
18.5 |
4.0 |
230 |
125-160B |
125 |
83 138 166 |
21.7 38.3 46.1 |
27 24 21 |
73 |
2900 |
15 |
4.0 |
215 |
125-200 |
125 |
96 160 192 |
26.7 44.4 53.3 |
55 50 46 |
77 |
2900 |
37 |
5.5 |
395 |
125-200A |
125 |
90 150 180 |
25 41.7 50 |
48.4 44 40.5 |
76 |
2900 |
30 |
5.5 |
380 |
125-200B |
125 |
83 138 166 |
21.7 38.3 46.1 |
41.3 37.5 34.5 |
75 |
2900 |
22 |
5.5 |
320 |
125-250 |
125 |
96 160 192 |
26.7 44.4 53.3 |
87 80 73 |
75 |
2900 |
55 |
5.0 |
580 |
125-250A |
125 |
90 150 180 |
25 41.7 50 |
76 70 84 |
74 |
2900 |
45 |
5.5 |
490 |
125-250B |
125 |
83 138 166 |
21.7 38.3 46.1 |
65 60 55 |
73 |
2900 |
37 |
5.5 |
430 |
125-315 |
125 |
96 160 192 |
26.7 44.7 53.3 |
133 125 119 |
70 |
2900 |
90 |
5.0 |
790 |
125-315A |
125 |
90 150 180 |
25 41.7 50 |
117 110 104.6 |
70 |
2900 |
75 |
5.0 |
710 |
125-315B |
125 |
86 143 172 |
23.9 39.7 47.8 |
106.4 100 95.2 |
69 |
2900 |
75 |
5.0 |
705 |
125-315C |
125 |
80.5 134 161 |
22.4 37.2 44.7 |
96 88 86 |
67 |
2900 |
55 |
5.0 |
585 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
|
150-125 |
150 |
96 160 192 |
26.7 44.4 53.3 |
22.6 24 17 |
66 76 76 |
2900 |
11 |
4.0 |
210 |
150-125A |
150 |
90 150 180 |
25 41.7 50 |
18 16 13.6 |
77 |
2900 |
7.5 |
4.0 |
130 |
150-160 |
150 |
96 160 192 |
26.7 44.4 53.3 |
36 32 27 |
75 |
2900 |
22 |
4.0 |
270 |
150-160A |
150 |
90 150 180 |
25 41.7 50 |
32 28 23.5 |
76 |
2900 |
18.5 |
4.0 |
230 |
150-160B |
150 |
84 140 168 |
23.3 39 46.7 |
27 24 21 |
73 |
2900 |
15 |
4.0 |
220 |
150-200 |
150 |
96 160 192 |
26.7 44.4 53.3 |
55 50 46 |
77 |
2900 |
37 |
5.5 |
395 |
150-200A |
150 |
90 150 180 |
25 41.7 50 |
48.4 44 40.5 |
76 |
2900 |
30 |
5.5 |
380 |
150-200B |
150 |
84 140 168 |
23.3 39 46.7 |
41 38 34 |
75 |
2900 |
22 |
4.0 |
275 |
150-250 |
150 |
140 200 260 |
38.9 55.6 72.2 |
87 80 73 |
75 |
2900 |
75 |
5.0 |
630 |
150-250A |
150 |
131 187 243 |
36.4 51.9 67.5 |
76 70 84 |
74 |
2900 |
55 |
5.5 |
530 |
150-250B |
150 |
121 173 225 |
33.5 48.1 62.5 |
65 60 55 |
73 |
2900 |
45 |
5.5 |
480 |
150-315 |
150 |
140 200 260 |
38.9 55.6 72.2 |
133 125 119 |
70 |
2900 |
110 |
5.0 |
1080 |
150-315A |
150 |
131 187 243 |
36.4 51.9 67.5 |
117 110 104.6 |
70 |
2900 |
90 |
5.0 |
820 |
150-315B |
150 |
121 173 225 |
33.5 48.1 62.5 |
106.4 100 95.2 |
69 |
2900 |
75 |
5.0 |
770 |
150-315C |
150 |
112 160 208 |
31.3 44.4 57.8 |
96 88 86 |
67 |
2900 |
55 |
5.0 |
640 |
150-350 |
150 |
96 160 192 |
26.7 44.4 53.3 |
153.6 150 142.8 |
80 |
2900 |
110 |
5.5 |
970 |
150-350A |
150 |
90 150 180 |
25 41.7 50 |
145.6 142 134.8 |
70 |
2900 |
90 |
5.2 |
790 |
150-350B |
150 |
84 140 168 |
23.3 39 46.7 |
138.6 135 127.8 |
65 76 74 |
2900 |
75 |
5.5 |
705 |
model |
caliber |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Required cavitation allowance |
weight |
|
mm |
m3/h |
L/S |
m |
% |
r/min |
KW |
(NPSH)r |
Kg |
Installation instructions
1. Before installation, check if the fasteners of the unit are loose and if there are any foreign objects blocking the flow inside the pump body to prevent damage to the impeller and pump body during pump operation.
2. The weight of the pipeline should not be added to the water pump during installation, and there should be separate supporting bodies to prevent pump deformation from affecting operational performance and service life.
3. In order to prevent impurities from entering the pump and blocking the flow channel, a filter with a cross-sectional area 3-4 times larger than the suction pipe should be installed in front of the pump inlet.
4. When a pump is used to transport hot water liquids, in order to prevent the pump from being subjected to thermal deformation of the pipeline, the pump may not be fixed with foot bolts. When the pipeline system expands and contracts due to heat, the pump and pipeline can move simultaneously.
5. For the convenience of maintenance and safety of use, a regulating valve should be installed on each inlet and outlet pipeline of the pump, and a pressure gauge should be installed near each inlet and outlet of the pump to ensure normal operation and service life of the pump within the rated range.
maintenance
1、 Preparation and inspection before starting:
1. Check whether the grounding device of the shielded motor and starting equipment is good and complete, whether the wiring is correct, and whether the contact is reliable.
2. For newly installed and long-term disabled shielded motors, the insulation resistance of the motor stator winding to ground should be checked before use.
3. The pipeline must be filled with the conveying liquid, otherwise it will affect the service life of the motor.
2、 Maintenance and upkeep during operation
1. Regularly record changes in power supply voltage and voltage imbalance. Excessive or insufficient power supply voltage, as well as the imbalance of three-phase voltage causing current imbalance, can all lead to motor overheating or other abnormal phenomena.
2. Regularly record the load current and imbalance of the electric pump. When an electric pump malfunctions, it mostly reflects a sharp increase in the current of the stator winding, causing the motor to overheat.
3. Regularly record the infusion temperature in the pipeline to ensure that the actual infusion temperature is lower than or equal to the infusion temperature specified on the nameplate, and to avoid the electric pump running in an over temperature state for a long time, which may reduce the service life of the motor.
4. Regularly record the pressure gauge values on the inlet and outlet ends of the electric pump. The pressure gauge value at the inlet must not be less than zero. The difference between the pressure gauge values at the outlet and the inlet must comply with the pressure values specified on the nameplate.
5. The electric pump must be vented before each use, and during long-term operation, it must be vented once a week. Due to the long-term operation of the pump, water molecules are stirred and impacted at high speed inside the electric pump, and the medium being transported has a certain temperature, resulting in the production of liquid slurry
6. Pay attention to the smell, vibration, and noise of the pump. The winding of the motor will emit a burnt insulation smell due to high temperature. Typical mechanical failures may manifest as vibrations and noise. Therefore, it was found that the abnormality was caused by an immediate power outage for inspection.
7. Regularly check the circulating fluid path of the electric pump and whether there is any blockage in the filtering device.
8. Regularly maintain and measure the gap between graphite bearings and shaft sleeves to ensure even clearance and reliable operation between the stator shielding sleeve and rotor shielding sleeve. In general, the following table is limited. If it exceeds the specifications in the table, it should be repaired or replaced.
Outer diameter of shaft sleeve (mm) |
Wear limit clearance (mm) |
Standard gap (mm) |
>18~30 |
0.40 |
0.131 |
>30~50 |
0.45 |
0.158 |
>50~80 |
0.50 |
0.192 |
9. Regularly check the fit clearance between the impeller mouth ring and the pump body, so the clearance will directly affect the performance of the electric pump. In general, if the clearance exceeds 1.5mm, a new impeller should be replaced. In special cases, repair technology can also be used to improve it.
Starting, running, and stopping
1、 Starting and rotating:
1. Fill the water and exhaust, open the inlet valve to allow the liquid to fully enter the pump chamber, open the exhaust valve at the top of the motor, and close the exhaust valve when it is full.
2. Close the outlet valve to reduce the starting current.
3. Check if all parts are normal.
4. Connect the power and start the engine to determine the correct direction of operation.
5. Gradually adjust the opening of the outlet valve to ensure that the pump operates within the rated performance range as much as possible.
6. If any abnormalities are found during the operation of the pump, it should be stopped immediately for inspection and troubleshooting.
7. Check if the motor current value and temperature rise meet the requirements.
2、 Parking
1. Close the valve of the discharge pipeline.
2. Cut off the power and stop the motor from running.
3. Close the inlet valve.
4. If the pump is not used for a long time, the liquid inside the pump should be drained completely.
Common causes and solutions of malfunctions
Fault phenomenon |
Possible causes |
Troubleshooting |
1. The water pump is not producing water |
1. The import and export valves are not open, and the inlet and outlet pipelines are blocked. The impeller flow channel is also blocked. 2. The motor is running in the wrong direction and has a slow speed due to phase loss. 3. The suction pipe is leaking air. 4. There is air inside the pump chamber. 5. Insufficient imported water supply. 6. Excessive pipeline resistance and improper pump selection. |
1. Check and remove blockages 2. Adjust the motor direction and tighten the motor wiring 3. Tighten all sealing surfaces and eliminate air 4. Open the exhaust valve on the top of the motor and exhaust all the air. 5. Shutdown inspection and adjustment. 6. Reduce pipeline bends and reselect pumps. |
2. Insufficient pump flow |
1. First, check according to the above reasons. 2. Partial blockage of pipeline and pump impeller, deposition of scale, and insufficient valve opening 3. The voltage is too low and the speed is too low. 4. The impeller mouth ring is worn and there is excessive leakage. |
1. First, exclude according to the above 2. Remove the obstruction and readjust the valve opening. 3. Voltage stabilization 4. Replace the impeller |
3. Excessive power |
1. Exceeding the rated flow usage. 2. The impeller or rotating components are rubbing against each other. 3. The sliding bearing is worn or broken. 4. The specific gravity of the medium is too high. |
1. Adjust the outlet valve to reduce the flow rate 2. Check, eliminate or replace components 3. Replace the sliding bearing 4. Modification |
4. Noise vibration |
1. Unstable pipeline support 2. Medium mixed with gas 3. Generating cavitation phenomenon 4. Friction between rotating parts |
1. Stable pipeline 2. Increase suction pressure and exhaust. 3. Reduce the vacuum degree 4. Check, adjust or replace |
5. Motor overheating |
1. Excessive traffic and overloaded operation 2. The stator and rotor are rubbing against each other. 3. Insufficient voltage 4. Blockage of cooling system pipeline |
1. Adjust the outlet valve to reduce the flow rate 2. Check and exclude 3. Voltage stabilization 4. Clearing blockages |