PBG vertical clear water pipeline shielded pump
The PBG vertical clear water pipeline shielded pump has absorbed advanced technology in the design and manufacturing of shielded pipeline pumps intern
Product details

Model Meaning
PBG立式屏蔽管道泵型号意义

Product Introduction
PBG vertical shielded pipeline pump has absorbed advanced technology in the design and manufacturing of shielded pipeline pumps internationally, and applied the shielding technology of motors to the field of liquid transportation. It is a series of new products launched to meet the needs of the domestic market.
The performance parameters of PBG vertical clear water pipeline shielded pump series basically comply with the provisions of international standard ISO2858 and national standard JB/T6878.2-93. It has significant characteristics such as design specifications, high universality, reasonable structure, stable performance, low noise operation, and no vibration, making it an ideal product to replace conventional horizontal centrifugal pumps and vertical pipeline pumps. The series performance parameters basically comply with the provisions of international standard ISO2858 and national standard JB/T6878.2-93.
There are a total of 67 varieties and 184 specifications in the entire series, with a performance range of 6.3~108m3/h flow rate, 12.5~125m head, equipped with a motor power of 0.37~160KW, and speeds of 1450r/min and 2900r/min.

Product Features
1. The pump structure is compact, the machine pump is integrated, and the volume is small. Its vertical structure has a small installation footprint, balanced operation, and no need for adjustment during installation.
2. The inlet and outlet of the pump are designed with flanges of the same specifications and located on the same centerline. They can be directly installed on the pipeline like valves, and the center is low for easy pipeline layout, making installation particularly convenient.
3. The pump is coaxial with the motor, with a short axial dimension, making the pump run more smoothly and with low noise.
4. Cancelling the traditional shaft seal method avoids the leakage of the conveying medium, thus having the significant feature of completely no leakage.
5. Replacing conventional motor rolling bearings with sliding bearings enables the pump to operate smoothly with extremely low vibration and noise.
6. Easy to install and repair bolts, no need to disassemble the piping system. Simply remove the connecting nut to extract all rotor components for inspection and maintenance.
7. The series and parallel operation of the pump can be carried out according to the requirements of flow rate and head.

application
1. PBG vertical clear water pipeline shielded pump is a common type used for transporting clear water and other liquids with physical and chemical properties similar to clear water. The medium is suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance transportation, HVAC refrigeration cycle, bathroom and other cold and warm water circulation pressurization and equipment matching, with a temperature not exceeding 80 ℃. Especially suitable for occasions with high requirements for vibration and noise, such as underground pump rooms, air conditioning refrigeration systems, etc.
2. PBG vertical clear water pipeline shielded pump hot water type is mainly used for conveying soft water with a temperature not exceeding 160 degrees Celsius and no solid particles. It is suitable for energy, metallurgy, chemical, textile, papermaking, hotels, restaurants, bathrooms, boiler hot water pressurized circulation transportation, urban heating system circulation and other fields.
3. The PBG vertical clear water pipeline shielded pump is an anti-corrosion type for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for industries such as petroleum, chemical, metallurgy, power, papermaking, food, pharmaceuticals, and synthetic fibers.

Conditions of Use
1. The medium must be a fluid that is soft water, thin, non solidifying, non flammable, and free of solid particles and fibers.
2. The medium temperature is 80 ℃ for ordinary type and 16080 ℃ for hot water type.
3. In general, the working pressure of the system should not exceed 1.2MPa, and the inlet pressure should not be less than 0.5MPa. In special circumstances, please contact our factory in advance.
4. The ambient temperature shall not exceed 40 ℃ and the relative humidity shall not exceed 95%.

STRUCTURE DESCRIPTION
The pump is a machine pump integrated structure, mainly composed of pump body, impeller, connecting body, sliding bearings, stator, rotor, shielding sleeve, motor housing and other components. The pump is a vertical single-stage single suction centrifugal pump, with the inlet and outlet on the same horizontal axis and the same diameter specifications. It can be directly installed on any part of the pipeline like a valve, making loading and unloading extremely convenient and occupying less space. The pump is integrated with the motor through a connecting body, and the bearings are made of imported graphite impregnated resin composite bearings. The motor stator and rotor are isolated by shielding sleeves. The bearing uses liquid as the lubricant and coolant, which has the characteristics of reasonable design and reliable operation. The pump is equipped with a base and can be directly installed on the foundation. Due to its low noise and vibration free characteristics, there is no need to install vibration isolators or pads during installation.

Structure diagram

PBG立式屏蔽管道泵结构说明
name
material
Serial Number
name
1
pump body
10
stator can
2
Sealing ring
11
Upper bearing seat
3
impeller
12
Rotor end cover
4
Lower bearing seat
13
stator can
5
Motor junction box
14
bearing
6
motor housing
15
pump cover
7
bearing
16
Cooling water pipe components
8
stator assembly
17
axle
9
rotor assembly

Spectrogram

PBG立式屏蔽管道泵型谱图

performance parameter

model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
20-110
20
1.8
2.5
3.3
0.5
0.69
0.91
16
15
13.5
25
34
35
2800
0.37
2.3
25
20-160
20
1.8
2.5
3.3
0.5
0.69
0.91
33
32
30
19
25
23
2900
0.75
2.3
29
25-110
25
2.8
4
5.2
0.78
1.11
1.44
16
15
13.5
34
42
41
2900
0.55
2.3
26
25-125
25
2.8
4
5.2
0.78
1.11
1.44
20.6
20
18
28
36
35
2900
0.75
2.3
28
25-125A
25
2.5
3.6
4.6
0.69
1.0
1.28
17
16
14.4
35
2900
0.55
2.3
27
25-160
25
2.8
4
5.2
0.78
1.11
1.44
33
32
30
24
32
33
2900
1.5
2.3
39
25-160A
25
2.6
3.7
4.9
0.12
1.03
1.36
29
28
26
31
2900
1.1
2.3
34
32-100
32
3.5
5
6.5
0.97
0.39
1.8
13.2
12.5
11.3
40
44
42
2900
0.75
2.3
28
32-125
32
3.5
5
6.5
0.97
0.39
1.8
22
20
18
40
44
42
2900
0.75
2.3
28
32-125A
32
3.1
4.5
5.8
0.86
1.25
1.61
17.6
16
14.4
43
2900
0.75
2.3
28
32-160
32
3.5
5
6.5
0.97
0.39
1.8
33.2
32
30.2
48
54
53
2900
1.5
2.0
39
32-160A
32
3.1
4.5
5.8
0.86
1.25
1.61
29
28
26.3
48
54
53
2900
1.1
2.0
39
32-200
32
3.5
5
6.5
0.97
0.39
1.8
50.5
50
48
34
40
42
2900
3
2.0
77
32-200A
32
2.8
4
5.2
0.78
1.11
1.44
44.6
44
42.7
34
40
42
2900
2.2
2.0
74
32-100(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
13.2
12.5
11.3
48
54
53
2900
0.75
2.0
32
32-100(I)A
32
4.4
6.3
8.3
1.22
1.75
2.32
13.2
12.5
11.3
48
54
53
2900
0.75
2.0
32
32-125(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
22
20
18
48
54
53
2900
1.1
2.3
34
32-125(I)A
32
4.4
6.3
8.3
1.22
1.75
2.32
17.6
16
14.4
40
45
41
2900
0.75
2.3
33
32-160(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
33.2
32
30.2
34
40
42
2900
2.2
2.0
47
32-160(I)A
32
4.1
5.9
7.8
1.14
1.64
2.17
29
28
26.3
34
39
39
2900
1.5
2.3
43
32-160(I)B
32
3.8
5.5
7.2
1.06
1.53
2.0
25.5
24
22.5
34
38
37
2900
1.1
2.3
38
32-200(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
50.5
50
48
26
33
35
2900
4
2.0
43
32-200(I)A
32
4.1
5.9
7.8
1.14
1.64
2.17
45
44
42
26
31
30
2900
3
2.3
62
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
40-100
40
4.4
6.3
8.3
1.22
1.75
2.31
13.2
12.5
11.3
48
54
53
2900
0.55
2.3
32
40-100A
40
3.9
5.6
7.4
1.08
1.56
2.06
10.6
10
9
52
2900
0.37
2.3
32
40-125
40
4.4
6.3
8.3
1.22
1.75
2.31
21
20
18
41
46
43
2900
1.1
2.3
34
40-125A
40
3.9
5.6
7.4
1.08
1.56
2.06
17.6
16
14.4
40
45
41
2900
0.75
2.3
33
40-160
40
4.4
6.3
8.3
1.22
1.75
2.31
33
32
30
35
40
40
2900
2.2
2.3
47
40-160A
40
4.1
5.9
7.8
1.14
1.64
2.17
29
28
26.3
34
39
39
2900
1.5
2.3
43
40-160B
40
3.8
5.5
7.2
1.06
1.53
2.0
25.5
24
22.5
34
38
37
2900
1.1
2.3
38
40-200
40
4.4
6.3
8.3
1.22
1.75
2.31
51
50
48
26
33
32
2900
4
2.3
74
40-200A
40
4.1
5.9
7.8
1.14
1.64
2.17
45
44
42
26
31
30
2900
3
2.3
62
40-200B
40
3.7
5.3
7.0
1.03
1.47
1.94
38
36
34.5
29
2900
2.2
2.3
52
40-250
40
4.4
6.3
8.3
1.22
1.75
2.31
82
80
74
24
28
28
2900
7.5
2.3
105
40-250A
40
4.1
5.9
7.8
1.14
1.64
2.17
72
70
65
24
28
27
2900
5.5
2.3
98
40-250B
40
3.8
5.5
7.0
1.06
1.53
1.94
61.5
60
56
23
27
26
2900
4
2.3
77
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
40-100(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
13.2
12.5
11.3
55
62
60
2900
1.1
2.3
34
40-100(I)A
40
8
11
14.5
2.22
3.05
4.03
10.6
10
9
60
2900
0.75
2.3
32
40-125(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
21.2
20
17.8
49
58
57
2900
1.5
2.3
38
40-125(I)A
40
8
11
14.5
2.22
3.05
4.03
17
16
14
57
2900
1.1
2.3
33
40-160(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
33
32
30
45
52
51
2900
3
2.3
56
40-160(I)A
40
8.2
11.7
15.2
2.28
3.25
4.22
29
28
26
44
51
50
2900
2.2
2.3
47
40-160(I)B
40
7.3
10.4
13.5
2.38
2.89
3.75
23
22
20.5
50
2900
1.5
2.3
43
40-200(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
51.2
50
48
38
46
46
2900
5.5
2.3
85
40-200(I)A
40
8.3
11.7
15.3
2.31
3.25
4.25
45.0
44
42
37
45
45
2900
4
2.3
75
40-200(I)B
40
7.5
10.6
13.8
2.08
2.94
3.83
37
36
34
44
2900
3
2.3
63
40-250(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
81.2
80
77.5
31
38
40
2900
11
2.3
145
40-250(I)A
40
8.2
11.6
15.2
2.28
3.22
4.22
71.0
70
68
38
2900
7.5
2.3
95
40-250(I)B
40
7.6
10.8
14
2.11
3.0
3.89
61.4
60
58
37
2900
7.5
2.3
94
40-250(I)C
40
7.1
10.0
13.1
1.97
2.78
3.64
53.2
52
50.4
36
2900
5.5
2.3
88
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
50-100
50
8.8
12.5
16.3
2.44
3.47
4.53
13.6
12.5
11.3
55
62
60
2900
1.1
2.3
36
50-100A
50
8
11
14.5
2.22
3.05
4.03
11
10
9
60
2900
0.75
2.3
35
50-125
50
8.8
12.5
16.3
2.44
3.47
4.53
21.5
20
17.8
49
58
57
2900
1.5
2.3
43
50-125A
50
8
11
14.5
2.22
3.05
4.03
17
16
14
57
2900
1.1
2.3
38
50-160
50
8.8
12.5
16.3
2.44
3.47
4.53
33
32
30
45
52
51
2900
3
2.3
59
50-160A
50
8.2
11.7
15.2
2.28
3.25
4.22
29
28
26
44
51
50
2900
2.2
2.3
51
50-160B
50
7.3
10.4
13.5
2.38
2.89
3.75
23
22
20.5
50
2900
1.5
2.3
47
50-200
50
8.8
12.5
16.3
2.44
3.47
4.53
52
50
48
38
46
46
2900
5.5
2.3
101
50-200A
50
8.3
11.7
15.3
2.31
3.25
4.25
45.8
44
42
37
45
45
2900
4
2.3
80
50-200B
50
7.5
10.6
13.8
2.08
2.94
3.83
37
36
34
44
2900
3
2.3
68
50-250
50
8.8
12.5
16.3
2.44
3.47
4.53
82
80
77.5
29
38
40
2900
11
2.3
160
50-250A
50
8.2
11.6
15.2
2.28
3.22
4.22
71.5
70
68
38
2900
7.5
2.3
115
50-250B
50
7.6
10.8
14
2.11
3.0
3.89
61.4
60
58
37
2900
7.5
2.3
114
50-250C
50
7.1
10.0
13.1
1.97
2.78
3.64
53.2
52
50.4
36
2900
5.5
2.3
108
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
50-100(I)
50
17.5
25
32.5
4.86
6.94
9.03
13.7
12.5
10.5
67
69
69
2900
1.5
2.5
41
50-100(I)A
50
15.6
22.3
29
4.3
6.19
8.1
11
10
8.4
65
67
68
2900
1.1
2.5
36
50-125(I)
50
17.5
25
32.5
4.86
6.94
9.03
21.5
20
18
60
68
67
2900
3
2.5
56
50-125(I)A
50
15.6
22.3
29
4.33
6.19
8.1
17
16
13.6
58
66
65
2900
2.2
2.5
48
50-160(I)
50
17.5
25
32.5
4.68
6.94
9.03
34.4
32
27.5
54
63
60
2900
4
2.5
72
50-160(I)A
50
16.4
23.4
30.4
4.56
6.5
8.44
30
28
24
54
62
59
2900
4
2.5
71
50-160(I)B
50
15.0
21.6
28
4.17
6.0
7.78
26
24
20.6
58
2900
3
2.5
59
50-200(I)
50
17.5
25
32.5
4.86
6.94
9.03
52.7
50
45.5
49
58
59
2900
7.5
2.5
108
50-200(I)A
50
16.4
23.5
30.5
4.56
6.53
8.47
46.4
44
40
48
57
58
2900
7.5
2.5
107
50-200(I)B
50
15.2
21.8
28.3
4.22
6.06
7.86
40
38
34.5
55
2900
5.5
2.5
100
50-250(I)
50
17.5
25
32.5
4.86
6.94
9.03
82
80
76.5
39
50
52
2900
15
2.5
175
50-250(I)A
50
16.4
23.4
30.5
4.56
6.5
8.47
71.5
70
67
39
50
52
2900
11
2.5
165
50-250(I)B
50
15
21.6
28
4.17
6.0
7.78
61
60
57.4
38
49
54
2900
11
2.5
165
50-315(I)
50
17.5
25
32.5
4.86
6.94
9.03
128
125
122
30
40
44
2900
30
2.5
310
50-315(I)A
50
16.6
23.7
31
4.61
6.58
8.6
115
113
110
30
40
44
2900
22
2.5
245
50-315(I)B
50
15.7
22.5
29.2
4.36
6.25
8.0
103
101
98
39
2900
18.5
2.5
215
50-315(I)C
50
14.4
20.6
26.8
4.0
5.72
7.44
86
85
83
38
2900
15
2.5
195
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
65-100
65
17.5
25
32.5
4.86
6.94
9.03
13.7
12.5
10.5
67
69
69
2900
1.5
2.5
46
65-100A
65
15.6
22.3
29
4.3
6.19
8.1
11
10
8.4
65
67
68
2900
1.1
2.5
41
65-125
65
17.5
25
32.5
4.86
6.94
9.03
21.5
20
18
60
68
67
2900
3
2.5
58
65-125A
65
15.6
22.3
29
4.33
6.19
8.1
17
16
14.4
58
66
65
2900
2.2
2.5
49
65-160
65
17.5
25
32.5
4.86
6.94
9.03
34.4
32
27.5
54
63
60
2900
4
2.5
75
65-160A
65
16.4
23.4
30.4
4.56
6.5
8.44
30
28
24
54
62
59
2900
4
2.5
75
65-160B
65
15.0
21.6
28
4.17
6.0
7.78
26
24
20.6
58
2900
3
2.5
63
65-200
65
17.5
25
32.5
4.86
6.94
9.03
52.7
50
45.5
49
58
59
2900
7.5
2.5
107
65-200A
65
16.4
23.5
30.5
4.56
6.53
8.47
46.4
44
40
48
57
58
2900
7.5
2.5
107
65-200B
65
15.2
21.8
28.3
4.22
6.06
7.86
40
38
34.5
55
2900
5.5
2.5
100
65-250
65
17.5
25
32.5
4.86
6.94
9.03
82
80
76.5
39
50
52
2900
15
2.5
180
65-250A
65
16.4
23.4
30.5
4.56
6.5
8.47
71.5
70
67
39
50
52
2900
11
2.5
170
65-250B
65
15
21.6
28
4.17
6.0
7.78
61
60
57.4
38
49
54
2900
11
2.5
170
65-315
65
17.5
25
32.5
4.86
6.94
9.03
127
125
122
32
40
44
2900
30
2.5
320
65-315A
65
16.6
23.7
31
4.61
6.58
8.6
115
113
110
32
40
44
2900
22
2.5
255
65-315B
65
15.7
22.5
29.2
4.36
6.25
8.0
103
101
98
39
2900
18.5
2.5
225
65-315C
65
14.4
20.6
26.8
4.0
5.72
7.44
86
85
83
38
2900
15
2.5
205
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
65-100(I)
65
35
50
65
9.72
13.9
18.1
13.8
12.5
10
67
73
70
2900
3
3.0
63
65-100(I)A
65
31.3
44.7
58
8.7
12.4
16.1
11
10
8
66
72
69
2900
2.2
3.0
53
65-125(I)
65
35
50
65
9.72
13.9
18.1
22
20
17
67
72.5
70
2900
5.5
3.0
99
65-125(I)A
65
31.3
44.7
58
8.7
12.5
16.1
17.5
16
13.6
66
71
69
2900
4
3.0
78
65-160(I)
65
35
50
65
9.72
13.9
18.1
35
32
28
63
71
70
2900
7.5
3.0
103
65-160(I)A
65
32.7
46.7
61
9.1
13.0
16.9
30.6
28
24
62
70
69
2900
7.5
3.0
103
65-160(I)B
65
30.3
43.3
56.3
8.4
12.0
15.6
26
24
21
69
2900
5.5
3.0
97
65-200(I)
65
35
50
65
9.72
13.9
18.1
53.5
50
46
55
67
68
2900
15
3.0
176
65-200(I)A
65
32.8
47
61
9.1
13.1
16.9
47
44
40
54
66
67
2900
11
3.0
166
65-200(I)B
65
30.5
43.5
56.6
8.5
12.1
15.7
40.6
38
33.4
65
2900
7.5
3.0
114
65-250(I)
65
35
50
65
9.72
13.9
18.1
83
80
72
52
59
60
2900
22
3.0
235
65-250(I)A
65
32.5
46.7
61
9.0
13.0
16.9
73
70
63
52
59
60
2900
18.5
3.0
205
65-250(I)B
65
30
43.3
56
8.3
12.0
15.6
62
60
54
58
2900
15
3.0
180
65-315(I)
65
35
50
65
9.72
13.9
18.1
128
125
121
44
54
57
2900
37
3.0
350
65-315(I)A
65
32.5
46.5
60.5
9.0
12.9
16.8
112.6
110
106.4
43
54
57
2900
30
3.0
335
65-315(I)B
65
31
44.5
58
8.6
12.4
16.1
102.5
100
98
53
2900
30
3.0
335
65-315(I)C
65
29
41
53.6
8.1
11.4
14.9
87
85
83
51
2900
22
3.0
270
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
80-100
80
35
50
65
9.72
13.9
18.1
13.8
12.5
10
67
73
70
2900
3
3.0
63
80-100A
80
31.3
44.7
58
8.7
12.5
16.1
11
10
8
66
72
69
2900
2.2
3.0
54
80-125
80
35
50
65
9.72
13.9
18.1
22
20
17
67
72.5
70
2900
5.5
3.0
99
80-125A
80
31.3
45
58
8.7
12.5
16.1
17.5
16
13.6
66
71
69
2900
4
3.0
79
80-160
80
35
50
65
9.72
13.9
18.1
35
32
28
63
71
70
2900
7.5
3.0
105
80-160A
80
32.7
46.7
61
9.1
13.0
16.9
30.6
28
24
62
70
69
2900
7.5
3.0
105
80-160B
80
30.3
43.3
56.3
8.4
12.0
15.6
26
24
21
69
2900
5.5
3.0
98
80-200
80
35
50
65
9.72
13.9
18.1
53.5
50
46
55
67
68
2900
15
3.0
175
80-200A
80
32.8
47
61
9.1
13.1
16.9
47
44
40
54
66
67
2900
11
3.0
165
80-200B
80
30.5
43.5
56.6
8.5
12.1
15.7
40.6
38
33.4
65
2900
7.5
3.0
115
80-250
80
35
50
65
9.72
13.9
18.1
83
80
72
52
59
60
2900
22
3.0
240
80-250A
80
32.5
46.7
61
9.0
13.0
16.9
73
70
63
52
59
60
2900
18.5
3.0
210
80-250B
80
30
43.3
56
8.3
12.0
15.6
62
60
54
58
2900
15
3.0
185
80-315
80
35
50
65
9.72
13.9
18.1
128
125
122
43
54
57
2900
37
3.0
355
80-315A
80
32.5
46.5
60.5
9.0
12.9
16.8
112.6
110
107.4
43
54
57
2900
30
3.0
340
80-315B
80
31
44.5
58
8.6
12.4
16.1
102.5
100
98
53
2900
30
3.0
340
80-315C
80
29
41
53.6
8.1
11.4
14.9
98
85
83
51
2900
22
3.0
275
80-350
80
35
50
65
9.72
13.9
18.1
146
150
142
55
66
67
2900
55
3.0
570
80-350A
80
31
44.5
58
8.6
12.4
16.1
138.4
142
134.8
65
2900
45
3.0
470
80-350B
80
29
41
53.6
8.1
11.4
14.9
131.4
135
127.8
63
2900
37
3.0
440
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
80-100(I)
80
70
100
130
19.4
27.8
36.1
13.6
12.5
11
66
76
75
2900
5.5
4.5
108
80-100(I)A
80
62.6
89
116
17.4
24.7
32.2
11
10
8.8
64
74
74
2900
4
4.5
87
80-125(I)
80
70
100
130
19.4
27.8
36.1
23.5
20
14
70
76
65
2900
11
4.5
163
80-125(I)A
80
62.6
89
116
17.4
24.7
32.2
19
16
11
68
74
65
2900
7.5
4.5
113
80-160(I)
80
70
100
130
19.4
27.8
36.1
36.5
32
24
70
76
65
2900
15
4.5
184
80-160(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
32
28
21
68
74
67
2900
11
4.5
174
80-160(I)B
80
60.6
86.6
112.5
16.8
24.1
31.3
72
24
18
72
2900
11
4.5
174
80-200(I)
80
70
100
130
19.4
27.8
36.1
54
50
42
65
74
73
2900
22
4.0
251
80-200(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
47.5
44
37
64
73
72
2900
18.5
4.0
220
80-200(I)B
80
61
87
113
16.9
24.2
31.4
41
38
32
71
2900
15
4.0
198
80-250(I)
80
70
100
130
19.4
27.8
36.1
87
80
68
62
69
68
2900
37
4.0
330
80-250(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
76
70
59.5
61
68
67
2900
30
4.0
315
80-250(I)B
80
61
87
113
16.9
24.2
31.4
65
60
51
66
2900
30
4.0
315
80-315(I)
80
70
100
130
19.4
27.8
36.1
132
125
114
55
66
67
2900
75
4.0
675
80-315(I)A
80
66.5
95
123.6
18.5
26.4
34.3
119
113
103
55
66
67
2900
55
4.0
535
80-315(I)B
80
63
90
117
17.5
25
32.5
106.6
101
92
65
2900
45
4.0
420
80-315(I)C
80
58
82
107
16.1
22.8
29.7
90
85
76
63
2900
37
4.0
366
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
100-100
100
70
100
130
19.4
27.8
36.1
13.6
12.5
11
66
76
75
2900
5.5
4.5
113
100-100A
100
62.6
89
116
17.4
47
32.2
11
10
8.8
64
74
74
2900
4
4.5
91
100-125
100
70
100
130
19.4
27.8
36.1
23.5
20
14
70
76
65
2900
11
4.5
169
100-125A
100
62.6
89
116
17.4
24.7
32.2
19
16
11
68
74
63
2900
7.5
4.5
118
100-160
100
70
100
130
19.4
27.8
36.1
36.5
32
24
70
76
65
2900
15
4.5
191
100-160A
100
65.4
93.5
121.6
18.2
26.0
33.8
32
28
21
68
74
67
2900
11
4.5
181
100-160B
100
60.6
86.6
112.5
16.8
24.1
31.3
27
24
18
72
2900
11
4.5
181
100-200
100
70
100
130
19.4
27.8
36.1
54
50
42
65
74
73
2900
22
4.0
245
100-200A
100
65.4
93.5
121.6
18.2
26.0
33.8
47.5
44
37
64
73
72
2900
18.5
4.0
215
100-200B
100
61
87
113
16.9
24.2
31.4
41
38
32
71
2900
15
4.0
193
100-250
100
70
100
130
19.4
27.8
36.1
37
80
68
62
69
68
2900
37
4.0
345
100-250A
100
65.4
93.5
121.6
18.2
26.0
33.8
76
70
59.5
61
68
67
2900
30
4.0
330
100-250B
100
61
87
113
16.9
24.2
31.4
65
60
51
66
2900
30
4.0
330
100-315
100
70
100
130
19.4
27.8
36.1
132
125
114
55
66
67
2900
75
4.0
689
100-315A
100
66.5
95
123.6
18.5
26.4
34.3
119
113
103
65
66
67
2900
55
4.0
549
100-315B
100
63
90
117
17.5
25
32.5
106.6
101
92
65
2900
45
4.0
439
100-315C
100
58
82
107
16.1
22.8
29.7
90
85
76
63
2900
37
4.0
385
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
100-100(I)
100
96
160
192
26.7
44.4
53.3
14
12.5
10
64
73
70
2900
11
4.5
115
100-125(I)
100
96
160
192
26.7
44.4
53.3
24
20
14
62
74
69
2900
15
4.5
168
100-125(I)A
100
84
140
168
23.3
39
46.7
20
17
12
64
72
68
2900
11
4.5
168
100-160(I)
100
96
160
192
26.7
44.4
53.3
36
32
27
69
79
75
2900
22
5.6
210
100-160(I)A
100
84
140
168
23.3
39
46.7
32
28
23.5
66
76
72
2900
18.5
5.0
210
100-200(I)
100
96
160
192
26.7
44.4
53.3
53
50
45
69
79
78
2900
37
5.2
402
100-200(I)A
100
84
140
168
23.3
39
46.7
48
45
40
64
74
73
2900
30
4.5
395
100-200(I)B
100
60
100
120
16.7
27.8
33.3
43
40
36
72
2900
22
4.5
360
100-250(I)
100
96
160
192
26.7
44.4
53.3
83
80
72
65
77
74
2900
55
4.8
560
100-250(I)A
100
84
140
168
23.3
39
46.7
75
72
65
60
72
69
2900
45
4.5
420
100-250(I)B
100
60
100
120
16.7
27.8
33.3
68
65
58
70
2900
37
4.5
400
100-350
100
60
100
120
16.7
27.8
33.3
153.6
150
142
72
57
74
2900
90
4.0
950
100-350A
100
61
87
113
16.9
24.2
31.4
145.6
142
134
75
2900
75
4.0
830
100-350B
100
58
82
107
16.1
22.8
29.7
138.6
135
127
75
2900
55
4.0
600
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
125-100
125
96
160
192
26.7
44.4
53.3
13
12.5
12
82
2900
11
4.0
180
125-100A
125
86
143
172
23.9
39.7
47.8
10.4
10
9.6
77
2900
7.5
4.0
125
125-125
125
96
160
192
26.7
44.4
53.3
22.6
20
17
80
2900
15
4.0
220
125-125A
125
86
143
172
23.9
39.7
47.8
18
16
13.6
77
2900
11
4.0
210
125-160
125
96
160
192
26.7
44.4
53.3
36
32
28
78
2900
22
4.0
265
125-160A
125
90
150
180
25
41.7
50
31.5
28
24.5
76
2900
18.5
4.0
230
125-160B
125
83
138
166
21.7
38.3
46.1
27
24
21
73
2900
15
4.0
215
125-200
125
96
160
192
26.7
44.4
53.3
55
50
46
77
2900
37
5.5
395
125-200A
125
90
150
180
25
41.7
50
48.4
44
40.5
76
2900
30
5.5
380
125-200B
125
83
138
166
21.7
38.3
46.1
41.3
37.5
34.5
75
2900
22
5.5
320
125-250
125
96
160
192
26.7
44.4
53.3
87
80
73
75
2900
55
5.0
580
125-250A
125
90
150
180
25
41.7
50
76
70
84
74
2900
45
5.5
490
125-250B
125
83
138
166
21.7
38.3
46.1
65
60
55
73
2900
37
5.5
430
125-315
125
96
160
192
26.7
44.7
53.3
133
125
119
70
2900
90
5.0
790
125-315A
125
90
150
180
25
41.7
50
117
110
104.6
70
2900
75
5.0
710
125-315B
125
86
143
172
23.9
39.7
47.8
106.4
100
95.2
69
2900
75
5.0
705
125-315C
125
80.5
134
161
22.4
37.2
44.7
96
88
86
67
2900
55
5.0
585
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
150-125
150
96
160
192
26.7
44.4
53.3
22.6
24
17
66
76
76
2900
11
4.0
210
150-125A
150
90
150
180
25
41.7
50
18
16
13.6
77
2900
7.5
4.0
130
150-160
150
96
160
192
26.7
44.4
53.3
36
32
27
75
2900
22
4.0
270
150-160A
150
90
150
180
25
41.7
50
32
28
23.5
76
2900
18.5
4.0
230
150-160B
150
84
140
168
23.3
39
46.7
27
24
21
73
2900
15
4.0
220
150-200
150
96
160
192
26.7
44.4
53.3
55
50
46
77
2900
37
5.5
395
150-200A
150
90
150
180
25
41.7
50
48.4
44
40.5
76
2900
30
5.5
380
150-200B
150
84
140
168
23.3
39
46.7
41
38
34
75
2900
22
4.0
275
150-250
150
140
200
260
38.9
55.6
72.2
87
80
73
75
2900
75
5.0
630
150-250A
150
131
187
243
36.4
51.9
67.5
76
70
84
74
2900
55
5.5
530
150-250B
150
121
173
225
33.5
48.1
62.5
65
60
55
73
2900
45
5.5
480
150-315
150
140
200
260
38.9
55.6
72.2
133
125
119
70
2900
110
5.0
1080
150-315A
150
131
187
243
36.4
51.9
67.5
117
110
104.6
70
2900
90
5.0
820
150-315B
150
121
173
225
33.5
48.1
62.5
106.4
100
95.2
69
2900
75
5.0
770
150-315C
150
112
160
208
31.3
44.4
57.8
96
88
86
67
2900
55
5.0
640
150-350
150
96
160
192
26.7
44.4
53.3
153.6
150
142.8
80
2900
110
5.5
970
150-350A
150
90
150
180
25
41.7
50
145.6
142
134.8
70
2900
90
5.2
790
150-350B
150
84
140
168
23.3
39
46.7
138.6
135
127.8
65
76
74
2900
75
5.5
705
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg

Installation instructions
1. Before installation, check if the fasteners of the unit are loose and if there are any foreign objects blocking the flow inside the pump body to prevent damage to the impeller and pump body during pump operation.
2. The weight of the pipeline should not be added to the water pump during installation, and there should be separate supporting bodies to prevent pump deformation from affecting operational performance and service life.
3. In order to prevent impurities from entering the pump and blocking the flow channel, a filter with a cross-sectional area 3-4 times larger than the suction pipe should be installed in front of the pump inlet.
4. When a pump is used to transport hot water liquids, in order to prevent the pump from being subjected to thermal deformation of the pipeline, the pump may not be fixed with foot bolts. When the pipeline system expands and contracts due to heat, the pump and pipeline can move simultaneously.
5. For the convenience of maintenance and safety of use, a regulating valve should be installed on each inlet and outlet pipeline of the pump, and a pressure gauge should be installed near each inlet and outlet of the pump to ensure normal operation and service life of the pump within the rated range.

maintenance
1、 Preparation and inspection before starting:
1. Check whether the grounding device of the shielded motor and starting equipment is good and complete, whether the wiring is correct, and whether the contact is reliable.
2. For newly installed and long-term disabled shielded motors, the insulation resistance of the motor stator winding to ground should be checked before use.
3. The pipeline must be filled with the conveying liquid, otherwise it will affect the service life of the motor.
2、 Maintenance and upkeep during operation
1. Regularly record changes in power supply voltage and voltage imbalance. Excessive or insufficient power supply voltage, as well as the imbalance of three-phase voltage causing current imbalance, can all lead to motor overheating or other abnormal phenomena.
2. Regularly record the load current and imbalance of the electric pump. When an electric pump malfunctions, it mostly reflects a sharp increase in the current of the stator winding, causing the motor to overheat.
3. Regularly record the infusion temperature in the pipeline to ensure that the actual infusion temperature is lower than or equal to the infusion temperature specified on the nameplate, and to avoid the electric pump running in an over temperature state for a long time, which may reduce the service life of the motor.
4. Regularly record the pressure gauge values on the inlet and outlet ends of the electric pump. The pressure gauge value at the inlet must not be less than zero. The difference between the pressure gauge values at the outlet and the inlet must comply with the pressure values specified on the nameplate.
5. The electric pump must be vented before each use, and during long-term operation, it must be vented once a week. Due to the long-term operation of the pump, water molecules are stirred and impacted at high speed inside the electric pump, and the medium being transported has a certain temperature, resulting in the production of liquid slurry
6. Pay attention to the smell, vibration, and noise of the pump. The winding of the motor will emit a burnt insulation smell due to high temperature. Typical mechanical failures may manifest as vibrations and noise. Therefore, it was found that the abnormality was caused by an immediate power outage for inspection.
7. Regularly check the circulating fluid path of the electric pump and whether there is any blockage in the filtering device.
8. Regularly maintain and measure the gap between graphite bearings and shaft sleeves to ensure even clearance and reliable operation between the stator shielding sleeve and rotor shielding sleeve. In general, the following table is limited. If it exceeds the specifications in the table, it should be repaired or replaced.

Outer diameter of shaft sleeve (mm)
Wear limit clearance (mm)
Standard gap (mm)
>18~30
0.40
0.131
>30~50
0.45
0.158
>50~80
0.50
0.192


9. Regularly check the fit clearance between the impeller mouth ring and the pump body, so the clearance will directly affect the performance of the electric pump. In general, if the clearance exceeds 1.5mm, a new impeller should be replaced. In special cases, repair technology can also be used to improve it.

Starting, running, and stopping
1、 Starting and rotating:
1. Fill the water and exhaust, open the inlet valve to allow the liquid to fully enter the pump chamber, open the exhaust valve at the top of the motor, and close the exhaust valve when it is full.
2. Close the outlet valve to reduce the starting current.
3. Check if all parts are normal.
4. Connect the power and start the engine to determine the correct direction of operation.
5. Gradually adjust the opening of the outlet valve to ensure that the pump operates within the rated performance range as much as possible.
6. If any abnormalities are found during the operation of the pump, it should be stopped immediately for inspection and troubleshooting.
7. Check if the motor current value and temperature rise meet the requirements.
2、 Parking
1. Close the valve of the discharge pipeline.
2. Cut off the power and stop the motor from running.
3. Close the inlet valve.
4. If the pump is not used for a long time, the liquid inside the pump should be drained completely.

Common causes and solutions of malfunctions

Fault phenomenon
Possible causes
Troubleshooting
1. The water pump is not producing water
1. The import and export valves are not open, and the inlet and outlet pipelines are blocked. The impeller flow channel is also blocked.
2. The motor is running in the wrong direction and has a slow speed due to phase loss.
3. The suction pipe is leaking air.
4. There is air inside the pump chamber.
5. Insufficient imported water supply.
6. Excessive pipeline resistance and improper pump selection.
1. Check and remove blockages
2. Adjust the motor direction and tighten the motor wiring
3. Tighten all sealing surfaces and eliminate air
4. Open the exhaust valve on the top of the motor and exhaust all the air.
5. Shutdown inspection and adjustment.
6. Reduce pipeline bends and reselect pumps.
2. Insufficient pump flow
1. First, check according to the above reasons.
2. Partial blockage of pipeline and pump impeller, deposition of scale, and insufficient valve opening
3. The voltage is too low and the speed is too low.
4. The impeller mouth ring is worn and there is excessive leakage.
1. First, exclude according to the above
2. Remove the obstruction and readjust the valve opening.
3. Voltage stabilization
4. Replace the impeller
3. Excessive power
1. Exceeding the rated flow usage.
2. The impeller or rotating components are rubbing against each other.
3. The sliding bearing is worn or broken.
4. The specific gravity of the medium is too high.
1. Adjust the outlet valve to reduce the flow rate
2. Check, eliminate or replace components
3. Replace the sliding bearing
4. Modification
4. Noise vibration
1. Unstable pipeline support
2. Medium mixed with gas
3. Generating cavitation phenomenon
4. Friction between rotating parts
1. Stable pipeline
2. Increase suction pressure and exhaust.
3. Reduce the vacuum degree
4. Check, adjust or replace
5. Motor overheating
1. Excessive traffic and overloaded operation
2. The stator and rotor are rubbing against each other.
3. Insufficient voltage
4. Blockage of cooling system pipeline
1. Adjust the outlet valve to reduce the flow rate
2. Check and exclude
3. Voltage stabilization
4. Clearing blockages


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!