Shenzhen Saiyataike Instrument Equipment Co., Ltd
Home>Products>Number of InoLabMulti9310
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13352994958/13715370443/13352904356
  • Address
    916 Huamei Building, Huamei Industrial Park, Huamei Road, Songgang, Bao'an District, Shenzhen
Contact Now
Number of InoLabMulti9310
Number of InoLabMulti9310
Product details

Digital multi parameter water quality analysis

·model:inoLab Multi 9310

·Brand: GermanyWTW


Detailed Introduction

GermanyWTWLaboratory multi parameter water quality analyzer
9310The series of instruments adopt a fully digital architecture and are single channel multi parameter testers that can be connected to new modelsIDSDigital probe, testablepHDissolved oxygen and conductivity, with dissolved oxygen measured by fluorescence method.

model:inoLab Multi 9310

Product features:
Automatic recognition digital probe
Multi parameter tester, compatible withIDSDigital probe
QSCProbe condition monitoring function

Now laboratory instruments can also be connected to digital probes.9310Series digital multi parameter water quality analyzer can be testedpHORPConductivity and dissolved oxygen(fluorescence)Suitable for laboratories with requirements for document recording and guaranteed operational safety. By accessing differentIDSThe digital probe can test different parameters and is a digital multi parameter meter.

Innovative Design
The probe is equipped with an analog-to-digital converter and stores data related to the probe, such as the probe model, serial number, calibration status, etc. This design can avoid erroneous operations.

pHtest
have2Take measures to ensure accuracypHTesting, namelyQSCProbe condition monitoring function andCMCContinuous testing and monitoring function. Subsequent electrode calibration is based on the first calibration data as the reference point, ensuring very accurate monitoring of the current condition of the probe.

compatibility
Through oneIDSAdapter, can handle specialpHTest probe conversionIDSDigital probe.

Operation safety is guaranteed
In addition to prompting users through chart displays and simple and clear text, test results can also be tracked through user management functions.

Perfect document recording function
Multi parameter water quality analyzerUSBThe interface can achieve the function of quickly transmitting data; Built in data logger, capable of real-time recording of test results with date, time, andIDIdentification number, compliantGLPrequirement. In addition, users can also input the serial number of the probe to meet strict documentation requirements. The output result format iscsvTable, can be easily exportedexcelFormat.

9310PBuilt in printer, can directly print test results and calibration records.

The multi parameter water quality analyzer is supplied as a complete set and can be used immediately, with standard electrode brackets and AC transformers.

Technical Parameter

Multi-parameter controller

inoLab Multi 9310

display

BacklightLCDChart display

memory

500group(hand movement)/5000group(automatic)

Test channel

1individual

Recorder

Manual or automatic recording

interface

microUSBinterface

printer(Optional)

Optional thermal printer, width58 mm

power supply

Communication Transformer

4individual5name1.5Valkaline battery

4individual5name1.2Vrechargeable battery

IDS pHelectrode

SenTix 940

SenTix 950

SenTix 980

SenTix ORP 900

103740

103750

103780

103790

Range

0.000 … 14.000 ± 0.004

0.000 … 14.000 ± 0.004

mV: ± 1200.0 ± 0.2

temperature range

0 … 80 °C

0 … 80 °C

0 … 100 °C

0 … 100 °C

Reference electrolyte

Colloidal

3M KCl

3M KCl

3M KCl

Electrode film

cylindrical

cylindrical

Cone shaped

-

partition film

fibre

ceramics

platinum wire

ceramics

Electrode material

plastics

plastics

glass

glass

electrode size

length120 mm ± 2 mm,diameter12 mm ± 0.5 mm

Temperature Accuracy

± 0.2 °C

Electrode wire length

1.5rice

1.5rice

1.5rice

1.5rice

IDSConductivity electrode(IP 68)

TetraCon 925

LR 925/01

301710

301720

class type

4Polar graphite

2Polar stainless steel

Conductivity

10 μS/cm … 2000 mS/cm ± 0.5 %test value

0.01 … 200 μS/cm ± 0.5 %test value

Resistivity

0.5 Ohm cm ...100 kOhm cm ± 0.5 %test value

5 … kΩ 100 M± 0.5 % Ωtest value

salt linear measure

0.0 … 70.0 ± 0.5 %test value

TDS

0 … 1999 mg/l, 0.0 … 199.9 g/l ± 0.5 %test value

warm linear measure

0 … 100.0 °C ± 0.2 °C

Material of electrode body

epoxy resin

stainless steel

electrode size

Length:120 mm ± 1 mm,diameter15.3 mm ± 0.2 mm

length120 mm,diameter12 ± 0.2 mm

Electrode wire length

1.5rice

1.5rice

For pricing and other information on multi parameter water quality analyzers, please feel free to contact us by phone!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!