New lighting incubator GZX-250, LED light source, LCD temperature control display. For detailed prices, please consult customer service.
1New version of light incubatorScope of use
This product is an ideal equipment for cell tissue growth and cultivation, seed germination, seedling cultivation, feeding of insects and small animals, and cultivation and preservation of microorganisms. It is particularly suitable for production and scientific research in fields such as biotechnology, medical research, agricultural science, aquaculture, and animal husbandry, as well as for constant temperature and humidity experiments.
II GZX-250New version of light incubatorTECHNICAL INDEX
1. Model:GZX-250,
2,Capacity: 250L
3. Temperature control range under illumination: 10 ℃~50 ℃ Temperature control range without light: 5 ℃~50 ℃,
4. Uniformity: ± 1 ℃
5. Temperature fluctuation: ± 1 ℃,
6. Light intensity: ≤ 5000LX, six level adjustable Two sided illumination
7. Power consumption: 380W,
8. Adopting advanced microcomputer programmable technology for temperature control and LCD display screen.
9. Light touch adjustable switch, lightweight and flexible, LED digital display, multiple mode control adjustable. ,
10 compressors, using fluorine free and environmentally friendly refrigerants, with high efficiency and low energy consumption.
IIIArchitectural Overview
The outer shell of this product is made of steel plate, with a surface sprayed with plastic. The workshop is made of stainless steel plate, which is durable. The outer door is equipped with an observation window and a double-layer insulated glass door, making it easy to observe the experimental situation inside the box.
Adopting an intelligent microcomputer controller, it is easy to operate and can set multiple parameters (time, temperature) to simulate the natural environment. The box adopts axial flow fan for forced convection, improving the temperature uniformity performance inside the box
The lighting adopts LED lights, which are energy-saving, durable, and easy to maintain.
4、 Fault handling
1. When the temperature sensor malfunctions, the upper row of the temperature indicator window displays "□□□" when the measured temperature is above 60 ℃ or when there is an open circuit. When the temperature is below -5 ℃, the lower row of the temperature indicator window displays "□□□". When the above situation occurs, all outputs except for lighting will be automatically turned off. Please carefully check the wiring in the above situation. If there is no problem with the wiring, please replace the sensor.
1. Alarm function, AP is a value alarm. When the temperature measurement value is greater than AP ℃, the buzzer beeps, the alarm indicator light stays on, the lighting is turned off, the heating is turned off, and the cooling is turned on. If the alarm is not eliminated after 1 minute, the cycle window displays "tr", and the controller will automatically cut off the main switch K. If this situation occurs, restart the controller, otherwise the controller will not work properly. So, if the temperature inside the box is higher than the AP ℃ set value when the machine is just turned on, and the cooling of the compressor is still slow after running for 1 minute, causing the temperature measurement value to still be higher than AP ℃, the controller will automatically cut off K and cannot automatically restore it. The controller needs to be restarted. At this point, the AP can be appropriately increased, and after the temperature control stabilizes, the AP can be adjusted back to its original set value.
2. Other fault handling
Fault | reason | handle |
The upper or lower row of the controller displays 0000 Buzzer beeps | Sensor open circuit or short circuit Controller malfunction Temperature alarm value appears | replace replace Professional maintenance personnel |
The crew is not working | power failure Fuse blown The power socket is not properly connected | Waiting for electricity to be used Replace the fuse Reinstall or tighten |
Poor or no cooling effect | Refrigerant leakage capillary clogging Axial flow fan does not rotate | Please have professional personnel conduct maintenance Please have professional personnel conduct maintenance Repair or replace |
Running in chaos | Possible damage to the controller | replace |
Poor temperature effect | Cultivate objects that are too dense The ambient temperature is too high Frequent opening of doors Axial flow fan does not rotate | Leave a certain gap The ambient temperature is generally 20 degrees Celsius Reduce the number of door openings Replace the fan |
Not heated | Heating tube or relay damaged The thyristor is burnt out | replace replace |
There is a phenomenon of unlit lighting | Lamp legs not aligned or loose Electronic rectifier damaged The fluorescent tube is damaged | Align or press tightly replace replace |
The button does not function properly | Button damage Loose socket | Replace the panel Open the upper cover and insert it tightly |
Normal operation does not hear the sound of relay suction and discharge | Optocoupler damaged Relay damaged | replace replace |
5precautions
1. During the transportation of this product, it is prohibited to invert or tilt it at an angle greater than 45 degrees.
2. Do not frequently set the temperature and humidity during use to avoid overloading and affecting the lifespan of the compressor caused by frequent start-up.
3. This product has thermal resistance short circuit and open circuit protection. When the thermistor short circuits or breaks, the machine automatically stops heating or cooling.
4. The cultivation items inside the box should not be stored too much and should be placed with gaps to facilitate air circulation inside the box.
5. Do not touch or collide with the temperature and humidity sensors inside the box to avoid damage and loss of control.
6. Do not use acidic, alkaline, or other corrosive solutions to wipe the surface. Use a dry step to clean it.
7. When the equipment is not in use, the box should be kept dry and the power should be cut off to set all switches to the 0 position.
8. This product is operated and maintained by professional personnel, and non electrical personnel are not allowed to repair the equipment. It is strictly prohibited to carry out point maintenance.
Please read the product manual carefully before using this device, and then perform all operations.