Sample clamping mechanism
1. When testing circular samples, high-precision three jaw self centering chuck is used for precise positioning of the samples, with concentricity better than 0.05mm.
2. The nickel plating process on the chuck body effectively avoids corrosion caused by humidity and oxidation in the environment.
3. The matching claws are made of non-magnetic materials to avoid the influence of magnetic conductivity of the fixture on the measurement results.
4. Sample size range (regular sample, directly adding product weight ≤ 5kg) (non-standard equipment beyond the range, customizable)
Meet the requirement that the claw can hold measurable samples below 60mm:
When measuring the distribution of magnetic field on the outer surface, the outer diameter is between 5mm and 90mm, and the height is ≤ 75mm
Outer diameter: Φ 5mm ∽ Φ 200mm, height ≤ 50mm
When measuring the magnetic field distribution on the inner surface, the inner diameter should be between 10mm and 79mm, and the height should be ≤ 75mm (depending on the sample size)
5. Our company can design testing fixtures based on sample shape and testing requirements.
Transmission mechanism
The device can adjust the distance between the probe and the surface of the sample to be tested through X, Y, and Z travel tables.
The W-axis adopts a precision electric rotating platform, which sends rotation commands to the stepper motor driver through the upper computer (testing software) to control the rotation angle of the sample. The small angle resolution can reach 0.01 degrees.
magnetometer
1. Magnetic field range: 1KG, 2KGs, 4KG, 8KG (customized for exceeding the range)
2. Small resolution: 0.01Gs
3. Measurement accuracy: better than 0.5%
Hall probe positioning mechanism (exclusive to Lianzhong)
The Hall probe adopts a full copper square handle and a positioning groove design, which, together with the horizontal and vertical positioning holes and positioning bolts on the L-shaped aluminum alloy probe bracket, can ensure the consistency of the probe clamping position.
Multi pole magnetic ring measuring device YC-3110RMTFUNCTION
1. The measurement software can run on the Windows 7 operating system, complies with Windows software specifications, and has intuitive and simple operation.
2. The measurement software has built-in FFT algorithm, which can perform harmonic analysis on the test waveform, display and print waveform spectrum analysis reports, and output each one
The amplitude data of harmonic components.
3. The measurement software automatically determines the number of poles of the magnetic ring and the polarity of the magnetic poles.
4. The test results include the peak value, angle, area, width, and half width of each magnetic pole, which users can choose to use or represent relative angles.
5. The test results include the maximum, minimum, mean, and standard deviation of each parameter.
6. The X-Y coordinate curve can be freely scaled, and the coordinates of each point on the curve can be dynamically tracked and displayed.
7. Supports various models of inkjet or laser printers, and user logos and company names can be added freely in the test report.
8. The test report is available in both Chinese and English formats, and can be simulated for display. The size and margins can be easily adjusted.
9. The test report can be converted into an image file for easy illustration in the paper.
10. Color test reports can be sent directly via email, which is much clearer and faster than fax.
11. It has database function and can output test data to EXCEL for easy analysis of test results. It can output measurement results or
Output magnetic field strength values for each test point.
12. The test results can be double clicked on the waveform to activate the single point capture function on the X-Y coordinate, and the current mouse selection can be displayed at the bottom of the software interface
The relative angle and magnetic field strength value of the midpoint.
Multi pole magnetic ring measuring device YC-3110RMTTechnical Parameter
project |
index |
|
|||
Input power supply |
AC 200~240V 50/60Hz 10A |
|
|||
External dimensions |
460mmx400mmx760mm (length * width * height) |
|
|||
Total power |
About 500W |
|
|||
system control |
PC+6616PX 16 bit data acquisition card |
|
|||
X single axis travel |
125mm, MANUAL |
|
|||
Y single axis travel |
25mm, MANUAL |
|
|||
Z-axis travel |
300mm, MANUAL |
|
|||
W rotation axis |
Angle resolution 0.01 degrees, rotation concentricity<=0.05mm |
|
|||
Test time |
Test time adjustable, fast by 16 seconds per lap |
|
|||
measuring range (Rule sample) (Out of range is non-standard equipment, can be customized) |
When measuring the magnetic field distribution on the outer surface of cylindrical workpieces: the outer diameter of the sample is between 5mm and 90mm (the rotor can clamp the shaft to measure a diameter of 200mm), and the height is ≤ 75mm When measuring the magnetic field distribution on the inner surface of cylindrical workpieces: the inner diameter of the sample is between 10mm and 79mm, and the height is ≤ 75mm |
|
|||
|
magnetometer |
range |
1KGs, 2KGs,4KGs,8KGs |
||
|
measurement accuracy |
Better than 0.5% |
|||
|
Measure small areas |
Standard probe: 2.9mm * 1.5mm Ultra thin probe (optional): 1.2mm * 0.5mm |
|||
|
temperature coefficient |
0.06%/℃ |
|||
Optional probe size (The standard configuration is a transverse probe, other non standard configurations are optional) |
1. Horizontal probe area 50x4x0.9mm (with Hall chip thickness of 1.5mm) (length * width * thickness) 2. (Optional) Longitudinal: Probe area 50x7mm (length * diameter) 3. (Optional) Ultra thin (with some flexibility): Probe area 50x2.5x0.35mm (length * width * thickness) 4. (Optional) Non standard: Customized size |
|
|||
Measurement parameters |
Measure the real-time magnetic waveform of radial multipole permanent magnets, including the maximum, minimum, and average values of the magnetic field, the peak value, angle, area, width, and half width of each magnetic pole, and analyze the frequency spectrum of the waveform. |
|
|||
A/D data acquisition |
16Bits, Rotation resolution:>12000 points/360 º; |
|
|||
Repeatability of measurement results |
Less than 0.5%; |
|
|||
measuring software |
The Windows 7 operating environment allows measurement data to be saved in EXCEL format on the hard drive and can be queried at any time; |
|
|||
measurement report |
XY coordinates, polar coordinates, and 3D coordinates |
|
|||
Qualification assessment |
Capable of calculating polarity distribution, magnetic pole area, and peak value, and making judgments according to standards; |
|
Standard configuration
Serial Number |
product name |
Model specifications |
quantity |
unit |
notes |
1 |
Multi pole magnetic ring testing platform |
Standard type |
1 |
cover |
Built in magnetometer and stepper motor controller |
2 |
data acquisition card |
PC6616 |
1 |
piece |
Built into industrial computer |
3 |
measuring software |
RMTest |
1 |
cover |
|
4 |
Industrial control computer |
Advantech IPC-510 or Advantech IPC-710 |
1 |
cover |
Equipped with an 18.5-inch LCD display |