SCKF103The trace moisture analyzer uses a new generation of high-performance, low-power ARM processor, combined with independently developed advanced digital circuit technology, ensuring stable operation and high accuracy. Widely used in industries such as electricity, petroleum, chemical, pharmaceutical, and food.

The types of detectable substances include:

1Gasoline, hydraulic oil, insulation oil, transformer oil, turbine oil, fire-resistant oil.

2Pentane, hexane, dimethylbutane, octane, dodecane, eicosane, octadecane, cyclododecane, decylcyclohexane, methylbutadiene, benzene, toluene, xylene, ethyltoluene, dimethylstyrene, tetracene, petroleum ether, cyclohexylamine, methylcyclohexylamine, cyclohexane, ethylcyclohexylamine, dicyclopentadiene, dimethylnaphthalene, trimethylstyrene, biphenyl, dihydrophenanthrene, fluorene, methylethylphenanthrene, isopropylbenzene, etc.

3Phenolic phenols, cresols, fluorophenols, chlorophenols, dichlorophenols, nitrophenols, etc

4Ether type diethyl ether, diethylene glycol monomethyl ether, diethylene glycol diethyl ether, polyethylene glycol diethyl ether, benzyl ether, fluorophenyl ether, iodobenzene ether, didecyl ether, and diheptyl ether

5All alcohols, all halogenated hydrocarbons, all lipids


Instrument Features

7Inch color LCD display screen, capacitive touch;
◆ Digital constant current electrolysis technology (patented technology);
Unique signal generation and detection circuit, high accuracy, strong anti-interference ability;
◆ Equipped with automatic compensation function for blank current;
◆ Equipped with automatic compensation function for balance point drift;
Introducing reagent factors to compensate for the electrolysis efficiency of Karl Fischer reagents

Suitable for both diaphragm electrolysis electrodes and non diaphragm electrolysis electrodes;

Real time updates of experimental data such as electrolysis curve and moisture content, with clear and intuitive experimental status;

◆ Record the total electrolysis water volume of Karl Fischer reagent, with Karl Fischer reagent failure alarm function;

◆ Measure electrode open circuit and short circuit alarms;

◆ Electrolytic electrode open circuit and short circuit alarm;

◆ Equipped with a large capacity lithium battery (optional), with a standby time of over 24 hours.

Technical Specifications

uMeasurement range: Moisture content: 1ppm-100%

Moisture content: 0 μ g-1000mg

Measurement and electrolysis parameters: ± 2 μ g (electrolysis water volume<1000 μ g) 0.2% (electrolysis water volume>1000 μ g)

Resolution: 0.1ug

uElectrolytic current: 0-600mA

uElectrolysis speed: 0-56 μ g/s

uPower supply voltage: DC24V

uApplicable ambient temperature: 5~40℃

uApplicable environmental humidity: ≤ 85%RH

uDimensions: 200 × 280 × 95mm

uWeight: Approximately 3.0kg