Tengzhou Hongxiang Analytical Instrument Co., Ltd
Home>Products>Methane Non Methane Total Hydrocarbon Online Analyzer NMHC-2
Methane Non Methane Total Hydrocarbon Online Analyzer NMHC-2
Methane Non Methane Total Hydrocarbon Online Analyzer NMHC-2
Product details

Product Introduction:

Instrument characteristics

NMHC-2 (Non Methane Total Hydrocarbon Detector, TVOC Detection) is designed to meet the current requirements of the domestic environmental protection industry for air quality testing. According to the "HJ/T38-1999" standard, based on the laboratory non methane total hydrocarbon chromatographic analyzer, our company's oilfield logging is adoptedA new product developed independently based on the technology of online analysis of mine gas, integrating advanced experience in the same industry at home and abroad. This product achieves the strongest practicality and highest cost-effectiveness according to the specific requirements of users, while meeting various performance indicators.


Instrument performance

  • Adopting a high-sensitivity FID detector.
  • Unique column switching and combination technology, advanced modular amplification systeminstrumentThe circuit is highly integrated and designed modularly, with extremely high operational stability.
  • On the basis of implementing full reverse control function, real-time display of various data spectra.
  • Fully automatic ten way valve online real-time injection, dedicated chromatographic column, fast analysis speed, Peak appears in 25 seconds and ensures no residue in the sample, with a wide analytical range (linear range up to 10)7
  • The instrument has power on self-test, power-off protection, automatic restart, and automatic ignitionVarious functions such as automatic calibration ensure high sensitivity, stability, and repeatability of the entire instrument.
  • The automatic sampling system can be connected to various ways of sample input, and the data processing system can be integrated with various central control systems The data transmission module of the system is connected to ensure real-time sampling, remote control, real-time transmission, and implementation Produce results in a timely manner.


Technical Parameter

project

Indicator parameters

Monitoring capability

Methane, non methane total hydrocarbons, volatile TVOC

range

Methane (0.1-10000) ppm (v/v) Non methane total hydrocarbons (0.04-10000) ppm (v/v)

detector

High sensitivity hydrogen flame ionization detector (FID)

detection limit

≤ 0.1ppm (methane) (v/v) ≤ 0.04ppm (v/v) (non methane total hydrocarbons)

repeatability

RSD≤2%

Analysis cycle

≤40S

Power supply

<300w,220V AC/50HZ

work environment

Temperature (5-50) ℃ Humidity (10% -90%) RH%

output

4-20mA RS232/RS485 Ethernet


Typical spectrogram


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!