Product advantagesFeatures-Guangpu Guichuan-
-
-
Equipment chamber: The equipment is made of stainless steel 304 or 316 material, which is corrosion-resistant and oxidation resistant to ensure a long service life
UV tube: stable light emission
Special ballast: The special ballast is moisture-proof, waterproof, and leak proof. The basement environment is humid, ensuring reliability and no leakage, and guaranteeing the personal safety of operators
Pure quartz sleeve: High UV transmittance greater than 90% ensures sterilization effect (ordinary quartz with a UV transmittance of 30% can reach 90%)
Customized according to customers, advanced automation systems such as automatic cleaning system, UV intensity detection system, remote control system, user-friendly touch screen operation interface, etc
maintenancemaintenance-Guangpu Guichuan-
Regular cleaning of quartz casingClose it firstMedium pressure ultraviolet sterilizerPower supply, remove the dust covers on both sides of the sterilizer, take out the lamp tube, remove the end caps, take out the "O" ring, and slowly remove the quartz tube. When cleaning the casing, use alcohol as a cleaning solution. After cleaning, the operator should not directly touch the surface of the quartz tube with their hands to avoid dirtying and affecting transparency. Align the quartz tube with the water seal holes at both ends, insert the quartz tube with equal clearance at both ends, and insert the "O" - shaped rubber ring. Slowly and evenly tighten the pressure cap, without excessive force, to avoid causing the quartz tube to break. Then conduct a water test. If there is water leakage, gently tighten the pressure cap until there is no water leakage. Finally, install the lamp tube and start running.
instructionsDescription-Guangpu Guichuan-
The medium voltage ultraviolet sterilizer is horizontally installed indoors, with the bracket fixed on the designated foundation or workbench. The sterilization device is located indoors (connected to the inlet and outlet), and in addition to considering the convenience of water supply and drainage and meeting the requirements of the process flow, attention should also be paid to leaving an installation position where the ultraviolet lamp tube and space can be extracted. The electrical control box is installed near the device, with a relative humidity of no more than 80 ℃, no corrosive gases, no conductive dust, and no strong vibration and impact.
This product is a pipeline type ultraviolet sterilizer, with two water outlets that can be selected as the inlet and outlet according to the pipeline direction. It can be placed horizontally or vertically according to user needs. To facilitate the replacement of light tubes and quartz tubes, there should be space of the same length on one side as the equipment.
After product installation, conduct a water test to ensure no water leakage, and then connect the power supply.
After connecting the power supply, the indicator light will turn on to ensure that the lamp head and lamp tube are connected properly. Then, press the "power switch" button on the dust cover and the lamp tube indicator light will turn on. The timer will rotate and wait for 3-5 seconds for the lamp tube to light up. At this time, the equipment will operate normally. After confirming that the lamp tube is on for 3-5 minutes, first open the water valve, and then open the water inlet valve. At this point, the machine will start running.

Guangpu Guichuan Medium Voltage Ultraviolet Disinfection Installation Case