Performance characteristics
Adopting the patented mechanical temperature compensation component technology of Zhenlan (patent number: ZL 2013 2 0041589.0), the measurement reading is corrected by changing the rotational volume of the gas meter when the temperature changes;
Adopting the patented gas meter redundancy control technology of Zhenlan (patent number: ZL 2015 1 0718165.7), it effectively avoids the gas meter from becoming slower and slower over long-term use, and can effectively reduce the transmission difference;
The non-destructive sealing process for gas meters with invention patents (patent number: ZL 2013 1 0029190.5) ensures long-term sealing and corrosion resistance of gas meters;
High operational sensitivity, with a starting flow rate of up to 1dm ³/h;
● Low pressure loss, less than 160Pa at a flow rate of 6m ³/h;
Good sealing performance, safer to use. The protective shell is coated with imported sealant and rolled with a seamless stainless steel sealing ring, allowing the gas meter to withstand a high-pressure sealing test of 75kPa;
The working temperature range is wide and can be used normally in an environment of -25 ℃ to+55 ℃;
A gas meter that can withstand a 1000h salt spray test can be configured.
Technical Parameter
Technical parameters/model | G1.6S-JT | G2.5S-JT | G4S-JT | ||
Nominal flow rate m ³/h | 1.6 | 2.5 | 4 | ||
Maximum flow rate m ³/h | 2.5 | 4 | 6 | ||
Minimum flow rate m ³/h | 0.016 | 0.025 | 0.04 | ||
Working pressure range kPa | 0.5~50 | ||||
Center temperature TSP | 20℃ | ||||
Working temperature range | -10℃~+40℃ | ||||
Indication error | tsp±5℃ in range |
0.1qmax≤q≤qmax | ±2% | ||
qmin≤0.1qmax | ±3.5% | ||||
tsp±5℃ Out-of-scope |
0.1qmax≤q≤qmax | ±2.5% | |||
qmin≤0.1qmax | ±4% | ||||
Pressure loss Pa | ≤200 | ||||
Product weight kg | 2 |
External dimensions

A | 90±0.50 110±0.50 130±0.50 | |
B | M26×1.5-6g M30×2-6g G¾"B G1"B | G1¼"B |
C | 238 | 230 |