Shanghai Shihong Instrument Co., Ltd
Home>Products>Mechanical flowmeter (gold rotor)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    136-7182-5945
  • Address
    No. 155 Henggang Road, Sijing Town, Songjiang District, Shanghai
Contact Now
Mechanical flowmeter (gold rotor)
Pure mechanical, no need for power supply, can be used to measure water, oil media, general gases, etc.
Product details

Mechanical flowmeteranother namePointer flowmeter; Pointer type flow indicator; Graduated flowmeter; Mechanical flow indicator

Mechanical flowmeter(Belonging to the category of instrument valves) is a necessary accessory for observing the flow of media in pipelines and measuring flow rates. Widely used in cooling systemsIn industrial production equipment such as lubrication systems, fuel supply systems, chemical, synthetic, pharmaceutical, food, power stations, and pump equipment, the ability to observe the flow reaction and flow rate of liquid, gas, steam and other media at any time is an indispensable accessory to ensure normal production. Its main connection methods: threaded, welded, flangeFormula.

Under the premise of transparent window glass, visually check whether the pointer swing angle matches the scale of the window to determine whether the medium is flowing or whether the flow rate is fast or slow, and whether the pipeline and equipment are operating normallygo.

Mechanical flowmeter advantage:

Mechanical flow meters do not require the installation of electronic instruments on the valve body. They operate in a mechanical mode by combining pointers with window scales, overcoming the historical problem of electronic flow meters requiring power to start the electronic instruments to achieve flow measurement effects and being unable to operate in harsh conditions such as high temperature and high pressure.

Mechanical flow meters do not require power to start and are operated mechanically by the impact force of medium flow. They are widely used in blast furnace cooling systems, lubrication systems, fuel supply systems, chemical, synthetic, pharmaceutical, food, power plants, pump equipment, petrochemical industries, and other fields due to their high temperature and high pressure resistance.

Mechanical flowmeterThere are various types such as gear type, float type, water meter type, etc; It is necessary to select the corresponding flowmeter based on the characteristics of the measuring medium.

The price of flow meters varies with the selection specifications, caliber, and configuration, and is not a fixed price product. It needs to be selected and quoted according to your operating conditions.


Mechanical flow meters for corrosive gases:
Media used: All corrosive acid, alkali, and salt solutions must be clean and free of impurities; All corrosive gases
Usage requirements: Limited by installation method, only for vertical installation, bottom in and top out type, accurate medium density needs to be provided
Advantages: Pure mechanical type, with PTFE lining inside the shell, no cumulative output or power supply, only displaying instantaneous flow rate (intelligent type requires additional charges), measuring liquid accuracy of 2.5; Gas measurement accuracy of 2.5, DN10-100
Common model: DQH-25FA-RP-1.6E-M1
Model annotation: Anti corrosion flowmeter, pure mechanical, measuring medium is hydrogen fluoride gas, DN25, The body material is 304 stainless steel lined with PTFE, vertically installed with a bottom in and top out type, temperature below 80 degrees, rated pressure of 1.6mpA, displaying instantaneous flow rate, no cumulative output, flange type, self installed flange and other fasteners.

样品展示

(Pure mechanical display instantaneous flow without cumulative vertical installation)

technical requirement

1. Measurement range: water (2.5-60000) L/h;

Air (0.07-2000) m3/H (at 0.101025 MPa, 20 ℃).

2. Accuracy levels: 1.5 and 2.5.

3. Range ratio: 10:1.

4. Work pressure: DN15-50, 4 MPa; DN80~100,1.6MPa。

5. Medium temperature: -80 ℃~200 ℃ (F46 flowmeter with lining 0 ℃~80 ℃).

6. Viscosity of liquid medium: DN15 < 5mPa · s; DN25~100<5mPa·s。

7. Connection methods: flange connection, threaded connection, etc.The flange adopts the GB/T9119.8-10 standard.

8. Total length: DN15-100 250mm.

9. Material of measuring tube: ordinary type 1Cr18Ni9Ti, corrosion-resistant type Cr18Ni12Mo2Ti, 316L, 316 lined F46, etc.

Product display of the same series:

智能型

(Intelligent type)

报警型

(Lower limit alarm type)

水平安装型

(Horizontal installation type)

大口径

(Large caliber size DN150)


Mechanical flowmeter--Elliptical gear flowmeter

Purpose: Suitable for measuring various oils and high viscosity medium liquids, such as crude oildiesel oilGasoline, resin, etc.

Advantages: Can be installed horizontally or vertically; The header can be rotated, and functions such as zero return alarm can be customized and added.

Installation method: flange, thread.

Required parameters for selection: fluid name, fluid viscosity, pipeline material and diameter, maximum and minimum working pressure, medium temperature, flow range, and on-site operating conditions requirements.

Common models:HLC-20A11

Model annotationmechanicalThe measuring medium is oil and the temperature is below 100 degrees, DN20, Rated pressure 4.0MPaThe body material is cast ironaccuracy0.5Display instantaneous flow and cumulative flow, pointer type, flange connection.

纯机械式 指针式

(Made of pure mechanical pointer type cast iron material)

Main technical parameters
1. Accuracy level: Ordinary type 0.5 level, high-precision 0.2 level
2. Medium pressure: 1.6MPa for ordinary type, 3.2MPa for high-pressure type
3. Viscosity range: Ordinary type: 0.6~200mpa. s, high viscosity: 200~1000mpa. s
4. Medium temperature: ordinary type<120 ℃, high-pressure type<200 ℃
5. Body material: cast iron, cast steel, stainless steel, etc
6. Rotating components: aluminum alloy, stainless steel, etc
7. Intrinsic safety explosion-proof: ExiallAT3
8. Connection method: flange connection DN10~DN100, threaded connection DN10~DN50
9. Installation method; Horizontal and vertical
10. Caliber series: DN10, 15, 20, 25, 40, 50, 80100
11. Pressure loss: ≤ 0.1 MPa

Sample display:

指针式 带回零

(Pure mechanical pointer type cast iron material with zero return function)

卫生型 不锈钢材质

(304 stainless steel material sanitary type with zero return function)

内螺纹连接 指针式

(Internal thread connection, pointer type 304 stainless steel material)


Performance parameters:
Accuracy levels: 1.5, 2.5
Ø Range ratio: 10:1
Ø Working pressure: DN15-50, 4 MPa; DN80~100,1.6MPa
Ø Medium temperature: F46 flowmeter with lining 0 ℃~80 ° C
Liquid medium viscosity: DN15<5mPa · s; DN25~100<5mPa·s
Ø Connection method: flange connection, flange adopts GB/T9119.8-10 standard
Ø Total length: DN15-100 250mm
Ø Measuring tube material: corrosion-resistant Cr18Ni12Mo2Ti, 316 lined F46, etc

Micro mechanical flowmeter:

The micro flow metal tube float type flow measuring instrument can measure liquids, gases, or vapors. The instrument adopts the principle of variable area measurement, and the measuring components consist of a conical measuring tube and a float. It has the characteristics of robustness, stability, and wide application range.

The connection methods include horizontal or vertical connections, and pressure regulators (constant flow valves) with inlet or outlet pressure changes can also be selected. They are widely used for small flow measurement and process control in industries such as petroleum, chemical, synthetic fiber, steel, food, light industry, and pharmaceuticals.

微型金属浮子流量计

Flow range:

Main technical parameters
1. Measurement range: Water (20 ℃) 0.3-100L/h
Air (20 ℃ 101325Pa) 5-3400L/h
2. Range ratio: 10:1
3. Accuracy level: LZZW series 4.0 level, LZDW series 2.5 level
4. Maximum working pressure: 2.5MPa or 6.4MPa, maximum 13MPa
5. Medium temperature: -80~+150 ℃, maximum 300 ℃
6. Environmental temperature: -25 to+65 ℃
7. Connection method: 1/4 "NPT internal thread, with the option of connecting with a Φ 6 (Φ 8) sleeve or according to user requirements
8. Limit alarm: 1-2 alarm switches (optional, explosion-proof level ExiaICT3-T6)
9. Electric remote transmission: Power supply voltage: 24 (1 ± 10%) V DC
Output signal: (4-20) mA DC, two-wire system (compatible with HART communication protocol)
Load resistance: ≤ 500 Ω (24V DC)
10. Protection level: IP65

Maintenance and upkeep of glass windows

1. The glass window is used to observe the flow reactions of liquids, gases, vapors, and other media, and should be kept clean and dust-free.

2. Window glass is a vulnerable component, so be careful when installing mirrors.

3. Glass has certain limitations in temperature and pressure resistance, which depend on the actual situation.

The following provide physical experimental parameters for the national standard glass manufacturing process:

Temperature resistance: tempered borosilicate glass ≤ 200 ℃, quartz glass ≤ 1000 ℃, aluminum silicon glass ≤ 450 ℃

Pressure resistance: Tempered borosilicate glass sheet ≤ 2.5MPa, quartz glass sheet ≤ 10.0MPa, aluminum silicate glass ≤ 6.4MPa

4. Allowing sudden temperature changes below 60 ℃, glass may rupture due to excessive temperature difference.


After sales and warranty

Shanghai Shihong Instrument Co., LtdAll products supplied:

Provide free telephone consultation, guidance on installation and debugging services;

Negotiate on-site guidance for installation, debugging, and other matters, and only charge reasonable travel expenses;

Large quantities can provide free on-site guidance for installation and debugging.

Service Objective:No matter how long the product is used, as long as you find us, we will solve all your problems until you are satisfied. We believe that our years of practical experience in the flowmeter industry can bring you satisfactory services.

24-Hour Hour Hotline:(Same WeChat account)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!