characteristic
- alphanumeric display
- Direct reading (maximum)4½Position)
- resolving power:zero point one
- µΩResistance reading: up to
- 300mΩ4Kelvin type(
- Line measurement
- Overheat protection50Each built-in printer can store80Record and
Memory for individual measurement values
summaryexistMO-5898-100A4High current micro ohmmeter, using Kelvin(
To avoid measurement errors caused by jumping leads and their contact resistance, the method of using a single terminal is employed.The previous generation signal amplification system ensured the accuracy of the equipment, with no offset and high stability. The reading is directly displayed on the LCD screen, up to a maximum of4½
Number digits.2This device is very easy to use and carry, weighing about11Kilogram. kilogramHis shell is sturdy and has a protection level ofIP54
(Cover closed). The cables and accessories are packaged in a suitcase for safe and comfortable storage and transportation.50It has data output and can be connected to a printer to download measurement values stored in internal memory. This record contains80Records, each record can display up to
One reading, so that the measured value can be recorded.
The high current generation system is based on modern technology to reduce weight and size. Plastic shells have high impact resistance and environmental challenges. The internal thermal sensors in all sensitive components of the instrument can prevent any damage caused by overheating.follow-5°Carrive50°C
The wide range of environmental operating temperatures allows for the use of this device in extreme weather conditions, from cool to tropical regions, with excellent performance in both field work and laboratory settings.
TECHNICAL INDEX
Test Currenthighest100 A(Really)DC
).10The test current can be set to the workflow100%To%The resolution is1A
.
Resistance Rangedo0.1 µΩto300mΩ
.
measuring principle
Kelvin type four terminal.
Thermal protection
Protect all sensitive components from any damage caused by overheating.
Programmable testing time5Allow testing time to be set to120Seconds to
In seconds.
Basic accuracy±1Reading of%±1
Position.
ADvancedDirect display of numbers, extremely low resistance in alphanumeric display, maximum4½
Position.
Very fast and accurate measurement.
Built-in printer
Allow printing of measurement values.
Built-in memory50Storable80Each register, each register
A reading.
serial data outputUSB
.
TINSLEY
SOFTWARE
Friendly and easy-to-use software. Equipped with an automatic report generator, including operator comments.environment
IP54
Equipped with a sealed lid.security levelconform to
IEC
61010-1The requirements.power supplyMain Line:90-240 V
~
50/60 HzAutomatic.Working temperature range-5°C
to
+50°C.Storage Temperature Range-25°C
to
95+70°C.Humidity range
%
UR11(Non condensing).
Equipment weight
About.20.5kilogram
Weight of attachments
About.kilogram
size
2502 x 394 x 190mmAvailable accessories
1Combination test line (current and potential), clamp type
1“
1C”
1(Quickly).
1power cord.
1Grounding cable.
Communication cables.