Professional Instrument Equipment and Testing Solution Supplier - JETYOO Industrial&Jianyou (Shanghai) Measuring Instrument Co., Ltd, a former Agilent product technical support engineer-Jian JETKEITHLEY Product Technology Application Engineer-RongyooA trade agency co founded in 2011 with a focus on technical support, aiming to break through the old and establish a new one! Fill the gap of most imported instrument and equipment manufacturers only setting up sales points in China, with weak or no technical support, and agent distributors only specializing in sales, not professional in pre-sales technical Q&A/testing plans, and not professional in after-sales training/maintenance calibration. Our technical sales engineers all have a bachelor's degree or above and over 10 years of experience in the testing industry. With our advanced and unique business philosophy, we specialize in providing instruments and equipment, testing solutions, technical training, and maintenance and measurement services to Chinese users. We are a leading company in the East China region of ShanghaiTechnology orientedA comprehensive service provider for instruments and equipment.
MICROTEST 7120 power meter standby power consumption tester7110 is used in environmental monitors, energy-saving lamps, exchange power supplies, transformers, uninterruptible power systems, power tools, 3C electronic products, household appliances, etc
The input current peak factor of MICROTEST Power Meter 7110/7120 can reach CF3/CF9, and it has excellent energy measurement characteristics for all data within the range. It also has the same level of power meter in terms of automatic file changing speedfastIt can quickly lock the current range and accurately analyze power consumption, with a measurement range from 0.001W to 16KW for average energy measurement. MICROTEST 7110/7120 energy measurement contains AC power consumption with DC component. For analyzing the current signal of asymmetric electrical appliances with positive and negative half cycles, the power factor PF obtained is more accurate. In response to the EU's standby specifications for electrical appliances, manufacturers are committed to reducing standby power consumption as much as possible and can help electrical appliance manufacturersrefinedAnalyze the standby power consumption of our own product and be able to perform long-term power consumption analysis with a personal computer.
AC/DC dual-purpose ampere/watt hour meter
Wide range 0.001W~16KW
Attached online software
Standby power resolution up to 0.001W
Display of peak factor ratio
Ability to analyze 50th order harmonics
1000 sets of measurement data storage space
Harmonics Analysis Function Specification
Analysis based on voltage or current (non variable frequency) to obtain a stable fundamental frequency for analysis
Frequency range 45Hz~440Hz
FFT data length 1024
FFT data format 32 bits
measuring items
1-50 total harmonic distortion, 1-50 order voltage and current V [n], A [n]
1-50th order voltage current distortion percentage V [n%], A [n%]
1-50 Watt W [n]
1-50th order watt distortion percentage W [n%]
1-50th order voltage and current angle DEG [n]
Vrms, Irms, Watt, PF
MICROTEST 7120 power meter standby power consumption tester7110 specification
model
Input power supply 100~240Vac, frequency: 50/60Hz
Screen display seven segment monitor
Input/output interface RS232+GPIB
6 sets of storage memory
Operating environment Temperature: 23 ℃± 5 ℃ Humidity: 20%~80%
Appearance dimensions W * H * D 227x101x300 mm
Weight 1.85 (Kg) without accessories
Measurement bandwidth DC/15Hz~10KHz, DC 15Hz~100KHz
Harmonic analysis function (optional function) Yes/No Yes/No
measurement data
model
The frequency measurement method uses voltage or current (non variable frequency) to obtain a stable fundamental frequency (within 1% variation) for measurement
Frequency range DC, 15Hz~10KHz DC, 15Hz~100KHz
Data length Dual 4096x16 RAM for voltage¤t
ADC resolution 16 bits
Sampling rate AC 50HZ/60HZ Basic sampling rate 100KSPS/120KSPS
Calculation accuracy Watt/VRMS/IRMS/MEAN/PF/Deg/Line filter 32bits
Frequency filter with 500Hz cutoff, based on 25MHz digital chip filter
Filter
500Hz -3db Butterworth based digital filter
50Hz -0.03% reading, 60Hz -0.05% reading
Frequency acquisition method: Voltage/current 100MHz fundamental frequency digital dynamic frequency counter chip
Phase detection is based on current, with mixed analog/digital detection (error within 5 degrees)
Range (fixed/automatic) 0.01A, 0.03A, 0.1A, 0.3A, 1A, 3A, 10A, 20A
Range (fixed/automatic) 10V, 30V, 100V, 300V, 600V
RMS/MEAN mode voltage¤trefinedDegree (23 ℃± 5 ℃)
>=15 Hz, f ≦ 45Hz ±(0.1% of reading + 0.4% of range)
>45 Hz, ≦ 66 Hz ±(0.1% of reading + 0.1 % of range)
>66 Hz, ≦ 1 kHz ±(0.1% of reading + 0.2 % of range)
>1 kHz, ≦ 10 kHz ±(0.07*f % of reading + 0.3% of range)
>10 kHz, ≦100 kHz ±(0.5% of reading + 0.5% of range) ±[% of reading]
The unit of F is 1KHz
When the L-Filter is set to ON: 45Hz~66Hz, the allowable error in the frequency band is -0.03%~-0.05 of reading
When measuring AC, if the fundamental frequency exceeds 200Hz, the F-Filter should be turned off to obtain the most accurate reading
**Only frequency band 7120 above 10KHz is available
DC mode voltage¤trefinedDegree (23 ℃± 5 ℃)
10V~600V ±0.2% reading ± 0.2% of range 0.01A ~20A ±{(0.2)% of reading + 0.2 % of range}±offset
When measuring DC current, it is necessary to add various levels of OFFSET error
Power (W) accuracy (23 ℃± 5 ℃)
AC power ranges (Auto or Manual) (40 ranges) up to 12KW
The maximum Power (W) value depends on the high range of the voltage file bit
15 Hz≦f DC ±0.2% reading ± 0.5% of range
45 Hz≦f≦66 Hz ±(0.1% of reading + 0.1 % of range)
66 Hz<f≦1 kHz ±(0.2% of reading + 0.2 % of range)
1 kHz<f≦10 kHz ±(0.4% of reading + 0.3 % of range)± [% of reading]
10 kHz<f≦100 kHz ±(0.5 % of reading + 0.5 % of range)±[% of reading]
Accompany allowable error conditions
Signal filter error (AC)
Frequency between 45 to 66 Hz: Add 0.3% of reading
Frequency between 45 to 66 Hz: Add 1% of reading outside the range
CF9 Error (DC) Add range tolerance * 3
The impact of phase error on power accuracy
When the power factor PF is 0, the error range of Watt is
Scenario 1: For 45 Hz<f
Scenario 2: For 45 Hz>f or f>66 Hz
Add ±{(3.5 + 0.5 × f)% of VA} for up to 100 kHz as reference data
The unit for frequency f is kHz.
When power factor 0<PF ≤ error range
When 0<PF≦1 (θ: phase angle of the voltage and current)
for 45 Hz≦f≦66 Hz. Add ± power reading *%
for f < 45 Hz, f >66 Hz. Add ± power reading *{ tanθ* (0.5×f+0.2) }%
Error within 12 months: Add ± (0.5% of reading)
Parameter measurement range
Vrms 0.1V ~ 600V PF 0.000 ~ ±1.000
Vdc 0.1V ~ 600V Deg -180°~ +180°
Irms 1mA ~ 20A THD 0.01% ~ 99.99%
Idc 1mA ~ 20A Hz 15Hz ~100kHz
Accessories/Fixtures
Standard accessories
Power cord, user manual electronic file CD, F71201 TEST BOX
Option
GPIB connection cable, TL218 adapter crocodile clip, TL208 2mm conversion test stick, computer connection software
Related products
PT-9200/9300 power switch/charger LED power testing system
PT-960F Universal Function Automatic Testing System
TL208 Conversion Test Rod (2mm)
TL218 adapter crocodile clip