Tianjin Haoling Technology Co., Ltd
Home>Products>Low temperature slot for drop hammer tear impact test
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 205-02, Comprehensive Office Building on the East Side of Huacheng Middle Road, Caozili Township, Wuqing District, Tianjin City
Contact Now
Low temperature slot for drop hammer tear impact test
The HL-80 type impact test low-temperature chamber for drop hammer tear test is a compressor refrigeration equipment developed by our company based on
Product details

Low temperature slot for drop hammer tear impact test

The HL-80 impact test low-temperature test is a compressor refrigeration equipment developed by our company based on the requirements for low-temperature devices in GB8363-07 "Method for Drop Weight Tear Test of Ferritic Steel".

HL-80The low-temperature discussion for impact testing is based on our company'sGB8363-07A compressor refrigeration equipment developed in accordance with the requirements for low-temperature devices in the "Method for Falling Weight Tear Test of Ferritic Steel". This equipment adopts a cascade compressor refrigeration technology, utilizing the principle of thermal balance and circulating stirring to achieve automatic uniform cooling and constant temperature of the sample, fully meeting the temperature control indicators specified by national standards. This low-temperature tank adopts single-chip microcomputer technology control, digital temperature value display, automatic temperature control, automatic timing, and automatic alarm. It is easy and safe to operate, with fast cooling speed, large volume, and high temperature control accuracy. This machine only requires a power supply and does not require water or liquid nitrogen, making it an ideal sample cooling and insulation device for low-temperature impact testing of metal materials.
Meet the requirements of American and European standardsASTM E23-02aEN10045ISO148ISO83Waiting for relevant international standards.
2、 Main technical parameters:
1Temperature control range: room temperature~-80
2Constant temperature accuracy:±0.5
3Cooling rate: room temperature~ 0Approximately ℃1.3/min
0℃~-40Approximately ℃1.0/min
-40℃~-60Approximately ℃0.8/min
-60℃~-80Approximately ℃0.6/min
4、 The largest external dimensions:1510×1010×1160mm(long×wide×tall)
5、 The largest workspace:760×440×220mm(long×wide×tall)
6Number of samples that can be loaded:22The size of the hammer impact specimen is long×Width:305×75mmAccording to the thickness of the original board, the length of the sample size is specified in the national standard×Width:305±5×76.2±1.5mm )
7Digital timer:1min9999min, Resolution1min
8Cooling medium: anhydrous ethanol or other non freezing liquid(60Rising)
9. Working power supply: 380V, 50Hz, 14KW

Online inquiry