Agilent 1100 liquid chromatograph(Second hand)

configuration

degasser

pump

Automatic sampler

Column temperature box

UV detector

Installation, warranty, after-sales service

The full range of Agilent 1100 pump systems


The capillary liquid phase pump system controlled by electronic flow control valve (EFC) has high accuracy and wide flow rate range
Column flow rate range: 1-20ul/min; 10-100ul/min (optional) 0.001-2.5ml/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump flow rate range: 0.001-100m1/min
Analytical pump system unit pump: 0.001-10m3/min Binary pump: 0.001-5m3/min Quaternary pump: 0.001-10m3/min


Agilent 1100 series injection system with a complete range of varieties


Standard manual sampler (analytical or preparation type)
Standard automatic sampler sample bottle capacity: up to 100 bottles (2mlx100) Injection volume: 0.1-100ul (0.1-1800ul) Optional
Micro disc automatic sampler sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional
Micro standard automatic sampler/microdisk automatic sampler injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
Constant temperature standard automatic sampler/micro disc automatic sampler Temperature range: 4-40 ℃, adjustable step 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system Sample bottle capacity: various specifications of test tubes
Up to 12 microplates (96 well plate, 384 well plate) injection volume: 0.1-5ul; 0.1-20ul


Agilent 1100 series detectors


Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190-600nm
Multi wavelength detector (MWD) wavelength range: 190-950nm (dual lamp source)
Diode Array Detector (DAD) wavelength range: 190-950nm (dual light source)
Fluorescence detector (FID) excitation wavelength: 200-700nm; emission wavelength: 280-900nm; spectral storage: full spectrum
Differential refractive index detector (RID) temperature control: room temperature+5 ℃ to 55 ℃, built-in automatic purge valve and automatic solvent circulation valve
Electrochemical detector (ECD) LC/MS quadrupole mass detector (MSD) LC/MS ion trap mass detector (Trap MSD)


Column temperature box and deaerator components


Column temperature range: 10 ℃ to 80 ℃ at room temperature Optional: Column switching valve
Vacuum online deaerator