Landscape light controller
Main applications
The product is mainly used for centralized control of landscape lighting fixtures installed in urban building lighting, squares, parks, rivers, bridges, tourist attractions, schools and other places. PT2007C landscape light controller, developed based on embedded systems, has functions such as acquisition, control, communication, and display, with 64 sets of scene control modes. The product adopts standardized and modular structural design, with small size, high reliability, and easy installation and maintenance. PT2007C Landscape Light Controllerpass throughWireless public network communication methods such as GPRS/CDMA/4G/5G/WiFiEstablish a real-time mutual access channel with the central Internet network, and the control center can adjust the on/off time, pattern, color, and effect of landscape lighting in real time, avoiding tedious manual on-site calibration work, improving scientific management methods, reducing light source pollution, and reducing electricity waste.
Product appearance diagram
On site installation physical picture
Technical parameter table (model: PT2007C)
Serial Number |
name |
Description of functions, parameters, and features |
1 |
VOLTAGE MONITOR |
Three phase voltage with lightning and voltage protection |
2 |
current monitoring |
three-phase current |
3 |
Scene control mode |
Automatic, manual, light control, holiday, DMX512 and other scene linkage control |
4 |
Signal monitoring |
Pulse input, with lightning protection, surge protection, and voltage protection |
5 |
Dimming output |
PWM pulse width modulation signal, DC 0-10V DC level signal |
6 |
Measurement interface |
Supporting national standards: DLT/645-2007 remote reading protocol and MODBUS industrial meter protocol |
7 |
communication model |
Wireless network communication methods such as GPRS/CDMA/4G/5G/WiFi |
8 |
DMX512 interface |
Support DMX512 joint control |
9 |
data shows |
Display of system clock, device ID number and other parameters |
10 |
status indicator |
Power supply, communication, input/output working status indication |
11 |
Backup power supply |
6-8 hour delayed work protection |
12 |
Connection |
Fully sealed anti misoperation electrical terminal |
13 |
Optical control interface |
Measurement range: 0~20000 Lux |
14 |
Constant temperature heating and dehumidification |
Automatic constant temperature control; Control accuracy range ± 0.25 ℃; Working heating rate 0.5 ℃/S |
15 |
Alarm Type |
Power outage, phase loss, tripping, open circuit, short circuit, over limit, light off and other fault group reports |
16 |
Working power supply (built-in) |
Switching power supply, input AC 100~250V/50Hz, output DC12/1A |
17 |
power waste |
Full load operation: 1W |
18 |
Installation method |
M4 screw fixation |
19 |
Volume |
178mm×182mm×60mm |
20 |
Weight |
1Kg |
21 |
ambient temperature |
-25 ℃~+70 ℃, relative humidity<100% |
22 |
degrees of protection provided by enclosure |
IP5X |
after-sale service
Product warranty for 1 year, 24-hour service hotline