The arc lamp test chamber can be used for selecting new materials, changing existing materials, or evaluating durability changes after material composition changes. It can simulate the changes in materials exposed to sunlight under different environmental conditions very well. Conduct aging tests by exposing material samples to the illumination and thermal radiation of arc lamps To evaluate the light and weather resistance of certain materials under high-temperature light sources Mainly used in automobiles, coatings, rubber, plastics, pigments, adhesives, fabrics, etc., it can be divided into two types according to testing standards and methods: air-cooled lamps and water-cooled lamps.
1. The air duct inside the box adopts a dual circulation system, consisting of a long axis axial flow fan, a stainless steel multi wing centrifugal fan, and a circulating air duct. The temperature inside the upper and lower air outlets is uniform, which improves the air flow rate, heating and cooling capacity, and significantly improves the temperature and humidity uniformity of the test box.
2. The refrigeration system adopts Taikang compressor unit
3. Core electrical components are all made by Schneider, etc
4. The box doors are equipped with double-layer filter observation windows
5. Adjustable lamp intensity
6. Focus on every detail and use with greater devotion
GB/T16422.2-2014 Plastics Laboratory Light Source Exposure Test Method (Part 2: Arc Lamp)
GB/T8430-98 Textiles - Tests for Color Fastness - Arc Lamp for Artificial Color Fastness
GB/T1865-2009 Paints, Varnishes, Artificial Air Aging, and Artificial Radiation Exposure
GB/T5137.3-96 Test Method for Radiation Resistance, High Temperature, Moisture Resistance, and Color Aging of Automotive Safety Glass
GB/T2423.24-95 Environmental testing for electrical and electronic products Part 2: Test methods, Test SQ: Simulating solar radiation on the ground
GB/T18244-2000 Aging test method for building waterproofing materials
GB/T3511-2008/ISO 4665:1998
GB/T15102-2006 impregnated film paper veneer artificial board
GB/T12831-91 Vulcanized rubber - Artificial climate (lamp) aging test method
GB/T14522-93 Accelerated Test Method for Artificial Climate of Plastic, Coating, and Rubber Materials Used in Mechanical Industry Products
Specification table: (Inner tank capacity or customized size according to user requirements)
|
PRODUCT MODEL |
GHXD-150 |
GHXD-225 |
GHXD-500 |
GHXD-1000 |
|
internal volume |
150L |
225L |
500L |
1000L |
|
Internal dimensions Height, width, and depth (mm) |
600*500*500 |
600*750*500 |
900*800*700 |
1000*1000*1000 |
|
Dimensionsmake an appointment Height, width, and depth (mm) |
1600*1020*1050 |
1700*1300*1050 |
2200*1450*1250 |
2200*1650*1550 |
|
supply voltage Pre installed power |
AC380V/10kw |
AC380V/12KW |
AC380V/15KW |
AC380V/17KW |
|
pipe |
1.8KW*1 unit |
1.8KW*2 pieces |
1.8KW*3 pieces |
1.8KW*4 pieces |
|
Standard production life |
About 1000 hoursOr choose piping for about 1600h |
|||
|
Light source: |
forced air cooling/Water coolingType arc |
|||
|
temperature range |
RT+10℃~70℃(display) |
|||
|
Black panel temperature |
63 ℃~95 ℃ (optional)control) |
|||
|
Humidity range |
Under the state of light cycling40~75% RH (determined by actual temperature);Dark cycle 30~98% RH (according to the set value) |
|||
|
temperature fluctuation |
± 0.5 ℃ (dark cycle) |
|||
|
temperature uniformity |
± 2 ℃ (dark cycle) |
|||
|
Humidity error |
± 2.0% RH (humidity>75% RH) ± 3.0% RH (humidity ≤ 75% RH) (dark cycle) |
|||
|
spectral wavelength |
300nm~800nm(Full spectrum)/340nm (UV spectrum) optional |
|||
|
Range of irradiance |
550W/㎡~1120W/㎡, accumulated light energy of 14000~67000KJ/㎡,radianceAutomatic measurement and control of irradiance; 340nm irradiance range 0.30-0.65 W/㎡ |
|||
|
Light cycle time |
1 to 999 hours |
|||
|
Glass window filter |
Borosilicate glass |
|||
|
Rainfall time |
1 to 9999 minutes, continuous rainfall adjustable |
|||
|
Rainfall cycle |
1-240 minutes, with adjustable intervals (interruptions) for rainfall |
|||
|
Rainwater pressure |
78~127kpa |
|||
|
Spray nozzle aperture |
Ф0.8mm |
|||
|
work environment |
﹢5℃~30℃ |
|||
|
Remark |
The above indicators are all under the condition of no sample load inside the boxAnd the environmentTest with average temperature ≤ 25 ℃income(Unless otherwise specified) |
|||