Labtech LPVTFD10R Programmable Freeze Drying Machine
Forced circulation temperature uniformity, stainless steel chamber and shelf; Safety gland system, optional vacuum seal, long-term preservation of sam
Product details
Fully automatic steam sterilization and vacuum back filling system, filled with sterilization air or nitrogen to prevent sample contamination
Forced circulation temperature uniformity, stainless steel chamber and shelf; Safety gland system, optional vacuum seal, long-term preservation of samples
model | LPVTFD10R | LPVTFD20R | LPVTFD30R | LPVTFD50R |
Dimensions W × D × H cm | 139×85×177 | 147×103×190 | 130×189×190 | 145×200×214 |
Cold trap size D × L cm | 30×35 | 30×48 | 70×62 | 88×62 |
compressor | 2HP×2 | 3HP×2 | 5HP×2 | 7.5HP×2 |
Maximum capacity L | 10 | 20 | 30 | 50 |
Water removal capacity (liters/day) | 8 | 16 | 24 | 40 |
Cold trap temperature | -75℃ ~ -80℃ | |||
Vacuum pump L/min | 417 | 648 | 841 | 841 |
Vacuum gauge/pressure | Electronic vacuum gauge, range: 0~999 microns//Final pressure 2 × 10-4 Torr | |||
defrost system | Hot gas solenoid system or heater defrosting system | |||
Freeze drying chamber Dia × L | 55×66 | 68×66 | 70×93 | 88×93 |
Stainless steel shelf size cm | 40W×50D×1.5H | 50W×80D×1.5H | ||
Number of shelves | 4(3+1) | 6(5+1) | 5(4+1) | 8(7+1) |
Heating temperature of the shelf | -40~+50℃ | -40~+50℃ | -40~+50℃ | -40~+50℃ |
power supply | 220V,50/60Hz, single phase | 380V,50/60Hz, three-phase |
vacuum pump |
Freeze drying chamber/heating plate | Multi manifold/vacuum tube | Freeze drying bottle | ||||||||||
model | Capacity L/min | model | describe | Size D × H | joint | model | model | capacity | interface | Size mm | |||
LSL-136 | 162 | DC1212 | Stainless steel 12 interface freeze-drying chamber | 230×275 | 1/2×12 | MC1224 Multiple manifold |
1/2×24 | LCF0040 | 40ml | 1/2 | 34×76 | ||
LSL-201 | 240 | LCF0080 | 80ml | 34×115 | |||||||||
LSL-16C | 384 | DC1316 | Stainless steel 16 interface freeze-drying chamber | 300×320 | 1/2×8 3/4×8 |
MC3412 Multiple manifold |
3/4×12 | LCF0120 | 120ml | 3/4 | 60×69 | ||
LSL-30C | 600 | LCF0150 | 150ml | 60×85 | |||||||||
LSL-40C | 800 | DC1218 | Stainless steel 18 interface freeze-drying chamber | 300×320 | 1/2×18 | MC1324 Multiple manifold |
1/2×12 3/4×12 |
LCF0300 | 300ml | 60×145 | |||
LSL-60C | 1200 | LCF0600 | 600ml | 3/4 | 90×135 | ||||||||
Directly drive the oil pump | HDC1316 | 3-layer heated freeze-drying chamber,+43 ℃ | 300×320 | 1/2×8 3/4×7 |
MC1208 Multiple manifold |
1/2×8 | LCF0900 | 900ml | 90×190 | ||||
Vacuum degree 5 × 10 ˉ 4 Torr | LCF1200 | 1200ml | 90×240 | ||||||||||
EF2561 oil mist trap | CDC3332 | Transparent heating freeze-drying chamber | 330×330 | LCV0012 vacuum tube 1/2 | LCF2000 | 2000ml | 90×380 | ||||||
IF2560 inlet filter | CDC3333 | Transparent manual pressure cover with heating chamber 330 × 330 | LCV0034 vacuum tube 3/4 | Various serum bottles (2ml~125ml) and ampoules (1ml~50ml) can also be provided STK0001 sealed opener, sealed ampoule with flame. |
|||||||||
VI2000Centrifugal concentrator | LPH1316 | Three layer heating plate for DC1316 | LCVA0012 vacuum tube |
3/8 | |||||||||
RH1204 | 10ml×24 | ||||||||||||
RH1560 | 1.5ml×60 | LPH1212 | Three layer heating plate for DC1212 |