Shanghai Youpu Industrial Co., Ltd
Home>Products>Laboratory wastewater treatment device
Laboratory wastewater treatment device
The UPFS-I series inorganic laboratory wastewater treatment device developed by Youpu Company has advanced technology, high degree of automation, no n
Product details
Characteristics of control system:
The UPFS-I series inorganic laboratory wastewater treatment device developed by Youpu Company is a specialized equipment for inorganic wastewater treatment in laboratories.
The UPFS-I series inorganic laboratory wastewater treatment device consists of wastewater classification and collection unit, wastewater regulation unit, wastewater deep treatment unit, sedimentation and separation unit, physical treatment unit, biological treatment unit, neutralization, and comprehensive wastewater purification unit. The comprehensive treatment of inorganic wastewater generated in the laboratory can effectively remove COD, BOD, SS, chromaticity, and heavy metal ions through chemical pretreatment, chemical deep treatment, precipitation, multi-stage disinfection and sterilization, filtration precipitation separation, and ultraviolet photocatalytic treatment processes. Different treatment technologies and control systems are used for wastewater treatment based on the composition of different experimental wastewater. The product has the advantages of advanced technology, high degree of automation, no need for dedicated personnel, good processing effect, small footprint, and convenient operation and management.


Technical specifications:


External dimensions weight power supply power Processing capacity
1200*750*1300
(L*W*H)
170KG AC220V-50Hz 370W 100-500L/D
1500*750*1800
(L*W*H)
440KG AC220V-50Hz 750W 1000-3000L/D


Performance indicators:

emission standard Integrated Wastewater Discharge (GB 8978-1996) Level III Standard
Fecal coliforms ≤500(MPN/L)
Intestinal pathogenic bacteria not detectable
enterovirus not detectable
CODcr ≤500(mg/l)
BOD5 ≤300(mg/l)
Volatile phenol ≤2 (mg/l)
PH 6-9
Total residual chlorine ≤0.5 (mg/l)
Processing capacity 0.1-3m ³/D (calculated based on 8 hours of work per day)
Other indicators Complies with the comprehensive sewage discharge standard GB 8978-1996
Table 2: Requirements for the Level 1 Standards for the Limits of Class 2 Pollutants.
control system Using PLC control technology, PLC、 High power relay amplification circuit with 4 analog inputs and outputs.
display 7-inch resolution 1024 * 680 (optional)
ambient temperature 0-50℃
Humidity range 10%-75%


Workflow: