Shanghai Yadu Electronic Technology Co., Ltd
Home>Products>LCD single-phase voltmeter
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18018578786
  • Address
    No. 22, Lane 928, Wenxiang Road, Songjiang District, Shanghai
Contact Now
LCD single-phase voltmeter
LCD single-phase voltmeter: YK4U series [LCD single-phase voltmeter] Model and specification: YK4U-21Y Panel size: 120 × 120mm Hole size: 111 × 111mm
Product details
液晶单相电压表
LCD single-phase voltmeter:YK4U series   LCD single-phase voltmeter

Model and specification: YK4U-21Y Panel size: 120 × 120mm Hole size: 111 × 111mm

Model and specification: YK4U-91Y Panel size: 96 × 96mm Hole size: 91 × 91mm

Model and specification: YK4U-31Y Panel size: 80 × 80mm Hole size: 76 × 76mm

Model and specification: YK4U-A1Y Panel size: 72 × 72mm Hole size: 67 × 67mm

Note: LCD single-phase voltmeter accuracy: 0.5 level, optional 485 communication, transmission output, input, alarm output, etc.

LCD single-phase voltmeter

1、 LCD single-phase voltmeter function:

LCD single-phase voltmeter can directly measure single-phase voltage parameters in the power grid, with a measurement range of AC220V, AC400V, AC100V (expandable range through PT). It uses digital LED digital display to display parameters. The single-phase digital voltmeter has the advantages of high accuracy, strong isolation, stable electromagnetic compatibility, anti vibration, and high cost-effectiveness. The LCD single-phase voltmeter can set PT and CT changes and can be used in energy management systems, substation automation, distribution network automation, residential power monitoring, industrial automation, intelligent buildings, intelligent distribution panels and switchgear. It can directly replace the original pointer type single-phase voltmeter.

1. LCD single-phase voltmeter:Equipped with high-performance processing chips and independent measurement chips, it has high measurement accuracy and fast operating speed.
2. :The display magnification, communication address, baud rate, etc. can be set through the buttons on the panel, making it very flexible and convenient to use.
3. LCD single-phase voltmeter:Measure single-phase voltage parameters, CT can be set arbitrarily.
4. Adopting LED digital display, digital zero and digital calibration, high precision, and extremely high cost-effectiveness.
5. LCD single-phase voltmeter:Input voltage AC220V, AC400V, AC100V (range can be expanded through PT)
6. 0-20mA or 4-20mA analog output. Alarm output, monitoring the upper and lower limits of the measured parameters.

Shanghai YaduLCD single-phase voltmeter   

IILCD single-phase voltmeterTECHNICAL INDEX

LCD single-phase voltmeter accuracy: display accuracy level 0.5
Display: Using digital LED digital tube to display parameters

LCD single-phase voltmeter voltage input:
Rated values: AC220V, AC400V/AC100V (range can be expanded through PT)
Overload: continuous 1.2 times instantaneous: voltage 2 times (10 seconds)
Power consumption:<1VA (per phase)
Impedance:>300k Ω

LCD single-phase voltmeter power supply:
Working power supply: AC220V, AC/DC80-265V, AC380V, DC24V, DC48V power supply. Please specify when ordering
Power consumption: ≤ 5VA

LCD single-phase voltmeter output module:
Pulse output: 2-channel power pulse output, optocoupler relay, constant: 5000imp/Kwh (Kvarh)
Switching input: 2-channel or 4-channel switching input
Switching output: 2-channel or 4-channel switching output
Analog output: 1-4 channels
Communication interface: RS485 interface MODBUS-RTU protocol, baud rates of 1200, 2400, 4800, 9600 optional

LCD single-phase voltmeter isolation withstand voltage: input and power>2kV, input and output>1kV, power box output>2kV
Insulation resistance: ≥ 100M Ω
Working conditions: Environmental temperature: -10~55 ℃, relative humidity ≤ 93%, no corrosive gas field, altitude ≤ 2500m

IIILCD single-phase voltmeterSelection table:

LCD single-phase voltmetermodel

YK4U-21Y

YK4U-91Y

YK4U-31Y

YK4U-A1Y

  basic function

Measure single-phase voltage

Communication (C)

1 route (optional)

1 route (optional)
1 route (optional)
1 route (optional)
Transmission (M)
1 route (optional)
1 route (optional)
1 route (optional)
1 route (optional)
Entering (K)
2 channels (optional)
2 channels (optional)
2 channels (optional)
2 channels (optional)
Open (Alarm J)
2 channels (optional)
2 channels (optional)
2 channels (optional)
2 channels (optional)
Panel size
120×120
96×96
80×80
72×72
Hole size
111×111
91×91
76×76
67×67
Power supply
Standard AC220V (except for communication and alarm, AC/DC80~265V power supply must be selected for other auxiliary functions),
Optional power supply without auxiliary functionsA3: AC380VD2: DC24VD4: DC48VAD: AC/DC80~265V)

 IIIExample diagram of wiring for LCD single-phase voltmeter

液晶单相电压表接线图

Power series products   
Digital single-phase ammeter:YK4I-21
DC current record table YA201R Single phase current voltage power factor table: YK4UIH series Single phase current recording table YA201R
Digital three-phase ammeter: YK4I series
DC Voltage Record Table YA201R Single phase current voltage frequency meter: YK4UIF series Three phase current recording table YA203R
Single phase voltmeter:YK4U series
Active Power Record Table YA201R Single phase current voltage active power meter: YK4UIP series Single phase voltage record table YA201R
Three phase voltmeter: YK4U series
Reactive Power Record Table YA201R Single phase current voltage reactive power meter: YK4UIP series Three phase voltage record table YA203R
LCD three-phase voltmeter:YK4U series
Frequency Record Table YA201R DC voltmeter: YK5U series Electricity Record Table YD300R
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!