VIP member
Kenker 5323 turbidity meter
If you are interested in this product, please click on the image. Product name: Kenker 5323 Turbidity Meter Product model: Kenker 5323 Product exhibit
Product details
The Kenker 5323 turbidity meter is suitable for measuring the scattering degree of light generated by insoluble particulate matter suspended in water or transparent liquids, and can quantitatively characterize the content of these suspended particulate matter,Designed with Kenker's proprietary technology, the optical system is used for turbidity measurement in various fields such as education, scientific research, drinking water treatment, wastewater treatment, surface water and groundwater detection, industrial process control, and product quality control.Kenker 5323 OptoelectronicsThe turbidity meter adopts a portable design and is economical,yesKenker's newly launched portable water quality analysis series products. It caters to the dual demands of customers for analytical instruments in terms of price and performance, with easy operation, powerful functionality, accuracy, and intuitiveness. It can be used for laboratory analysis, as well as for production site and field water quality testing, and on-site measurement. It has excellent system stability, greatly simplifies the experimental operation process, and makes the testing method more convenient, fast, and accurate.
As a highly integrated precision system, althoughThe Kenker 5323 has a very small external size, providing everything you need for even the most complex tests: high-quality reagents, reliable instruments, accurate and precise methods, and meticulous automatic prompts for operational information.
Every Kenker product undergoes strict calibration and verification before leaving the factory in a standardized laboratory to ensure a good user experience.
Product Features:
1. Portable and beautifully designed for handheld use, this sturdy carrying case is perfect for storing instruments and ensuring safe transportation. It is also easy to carry and suitable for on-site sample testing.
2. New electronic technology - new and fast processors, more possibilities, more convenience, and high accuracy.
2. Humanized design: two power supply modes, AC and DC, to adapt to different usage environments.
3. Kenker uses world-class components to achieve the pursuit of high efficiency and low loss, reflecting Kenker's consistent commitment to environmental protection and energy conservation.
4. LCD display screen: Clear, oversized fonts with strong readability.
5. Kenker has specially designed an efficient and long-lasting light source for 5323, with a measurement frequency of up to 300000 hours, ensuring maintenance free use and lifetime no need to replace the light source.
6. The precise optical system and color filter system ensure the superior performance of 5323 in terms of precision and stability.
7. The automatic range conversion function of * * and the assistance of Kenker's optimized linear compensation system make the measurement data more accurate and stable. At the same time, it avoids the influence of human error on the measurement results.
8. Ultra long standby time: Kenker has always adhered to the concept of environmental protection and energy conservation. In the design of Kenker 5323, a low-power CPU and integrated chip design are used, which is precise and reliable, with lower power consumption, ensuring the need for long-term continuous measurement outdoors or in the laboratory. At the same time, it can extend the service life of the battery. The test data from Kenker's factory validation laboratory shows that the power of five AA batteries is sufficient to support 6 months of testing time in the field.
9. The testing speed is fast, even at low temperatures in the northern hemisphere, it can be preheated in 25 seconds and completed in 3 seconds.
10. Automatic reading, stable, accurate, and reproducible testing.
11. Energy saving and low power consumption: In the design, Kenker has set an automatic shutdown program for the instrument to effectively save energy. When in use, the instrument will enter measurement mode upon startup. If you do not press any buttons for a long time, the instrument will automatically turn off the power. The automatic shutdown function can extend the lifespan of the battery.
12. Automatic power monitoring: The Kenker 5323 has a built-in power monitoring chip that automatically prompts you to replace the power supply when the battery is low. This function of the instrument avoids measurement errors caused by low battery power.
13. Measurement operation error alarm prompt.
15. Data can be downloaded directly to a computer through a USB interface, connected to a data cable, for easy storage and management of data. You can save measurement values or print test reports through software.
technical indicators:Specifications
Model number |
Kenker 5323 |
Measurement principle Minimum principle |
90°scattered light
|
*Minimum read out (NTU) |
0.1 |
Measuring range (NTU) |
0~100; 0~200
|
Linear error Basic error F.S |
±2.5%F. S
|
Repeatability |
≤1% |
Power supply |
DC 1.5V × 5 AA alkaline dry batteries AC 220V/50Hz power adapter |
External dimension |
235×75×65 mm |
Characteristics |
Password packaging box,
Automatic shutdown, AC/DC dual-use, data output
|
Online inquiry