Japanese universal M-600 AC/DC clamp meter/M-600 high-precision AC/DC clamp ammeter
The characteristics of the Japanese universal M-600 high-precision AC/DC dual-purpose clamp ammeter/AC/DC clamp meter
*Due to the use of magnetic balance, it does not interfere with the tested circuit
*The testing accuracy is independent of the position of the tested line conductor
*In AC/DC hybrid (i.e. overlapping) lines, AC or DC partial currents can be tested separately
Japan UniversalM-600 AC/DC dual-purpose clamp ammeter test specifications
Test function: DC current AC current (effective value)
Zero adjustment can be completed by pressing the zero adjustment key once
'0' can be used to test relative values when adjusting communication
Testing method: Clamp CT method
Jaw diameter: 20mm
Display: LCD display
The maximum display is' 1999 ', with unit markings attached
Polarity display (DC), low battery voltage display
Range overflow display
Data retention status display (D.H symbol lit)
Range: 3 ranges manually switched
Range 200mA 2000mA 10A
-Resolution 0.1mA 1mA 0.01A
Conventional parameters of the Japanese universal M-600 AC/DC clamp meter
Peak Hold: Maximum Hold
MINIHOLD (Minimum Hold)
Battery voltage: When below the operating voltage, the battery indicator lights up
Sampling speed: approximately 1.6 times per second
Test accuracy: (23 ℃± 5 ℃, below 80% RH)
AC/DC
200mA/2000mA range: ± 1.0% rdg ± 5dgt
10A range: ± 1.0% rdg ± 10dgt
Test circuit voltage: below AC/DC600V
Voltage endurance: AC3700V/1 minute (between iron core and box)
Working environment temperature and humidity: 0-50 ℃, below 80% RH (subject to no condensation)
Storage environment temperature and humidity: -10~60 ℃, below 75% RH (but subject to non condensation)
Power supply: 5 battery x 2
Power consumption: approximately 16mW
Size: 194 (length) x 76 (width) x 30 (height) mm
Weight: Approximately 340g
Accessory: Portable softcase, size 5 battery x 2, user manual