Japanese New Universe NV-500 Liquefied Gas (LP) Gas Detection Alarm
The characteristics of the NV-500 liquefied gas (LP) gas detection alarm in the Japanese new universe are that it can also monitor gas leaks when ther
Product details
Japanese New Universe NV-500 Liquefied Gas (LP) Gas Detection Alarm

| Features: It can also monitor gas leaks when there are abnormalities in the power supply lines (such as power outages). Continuous monitoring should be conducted within 30 minutes after a power outage, followed by intermittent monitoring for the next two days. In addition, the interval time will vary depending on the product setting point. In case of chaos caused by disasters, this product can also easily detect gas leakage sites (by voice reporting the leakage site). According to the instructions, there may be differences in the voice of the alarm department. In seismic tests equivalent to a magnitude of 7, this product can also function normally. Considering the seismic design in the event of a major earthquake disaster. Due to the molding insulation sealing treatment carried out in the electronic circuit department, the product is not easily damaged and the insulation performance is greatly improved. In addition, the chassis mechanism of this product has also been improved, enhancing the strength of the chassis. The gas concentration at the time of the alarm is clear at a glance. The battery has a lifespan diagnostic function. The operation of changing the alarm setting value is very simple. Zeroing adjustment and control range adjustment are both extremely simple. The voltage range is wide, ranging from 85V to 264V. It also comes with zero suppression function. Product specifications |
| model | NV-500 | ||||
| Monitoring points (optional) | 1 to 12 | ||||
| Detection Principle | Contact combustion type | ||||
| Detecting gas objects | Flammable gas | ||||
| Detection points/components | Two point monitoring method for one component | ||||
| Detection display range | 0~100%LEL | ||||
| Gas concentration display instrument | LCD Bar Chart Level Measuring Device (53 points, 2 columns) | ||||
| Alarm setting value display | Equipped with alarm setting and direct reading scale | ||||
| Backlight | There is a backlight | ||||
| Peak holding function | The peak holding function during alarm can be released by pressing the reset button | ||||
| Alarm setpoint/setpoint change | 24% LEL or 16% LEL | ||||
| Alarm accuracy | Within ± 25% of the alarm set value (under the same conditions) | ||||
| Alarm delay | Alarm within 30 seconds when the gas concentration reaches 1.6 times the alarm set value | ||||
| alarm display | When the alarm is triggered: the red light is displayed, the buzzer stops and lights up, completely locking (after the concentration level decreases, it can be released by pressing the reset button) | ||||
| ALARM | Standard Action | When the alarm is triggered: intermittent sound, press the reset button to release it | |||
| Voice alarm | During alarm: intermittent sound+voice alarm information | ||||
| External alarm output | Individual alarm contacts | Voltage free 1a contact (contact capacity AC100V2A) | |||
| Some individuals have voltage output | DC0-6-12V (below 20mA) | ||||
| Unified alarm contact point | Voltage free 1c contact (contact capacity AC100V2A) | ||||
| Centralized monitoring dashboard output | DC0-6-12V (below 20mA) | ||||
| External buzzer contact | Voltage free 1a contact (contact capacity AC100V2A) | ||||
| The external buzzer has voltage output | Signal with intermittent voltage (DC12V below 10mA) | ||||
| Alarm delay | Selection can be made by pulling the switch (fixed for 10 seconds) | ||||
| Power supply | AC85~264V | ||||
| power consumption | When using KD-5 | Diffuse (15+3.5n) VA | |||
| Use PE-2DC | Attraction type (15+7.5n) VA | ||||
| Optional purchase of backup power supply | Using batteries | Sealed lead-acid battery | |||
| Prevent over discharge function | Comes with over discharge prevention function | ||||
| Determination of battery life | Additional battery life assessment | ||||
| Battery voltage display | Two digit display LCD screen LED | ||||
| Paint color | Munsell color 2.5pB7.0/1.0 | ||||
Testing Department
KD-5B-N detection unit (diffusion type)
specifications
|
PE-2DC detection department (suction type)
| Model | PE-2DC | |
| Detection Principle | Contact combustion type; Hot wire semiconductor type (high sensitivity) | |
| Detecting target gas | Various flammable gases | |
| Indication range | According to another specification | |
| Pump power supply | DC24V±10% | |
| Can extend the distance | 1km (using 2mm ² cable) | |
| detection | Pump suction type | |
| Explosion proof structure | d2G4 | |
| Using cable wires | 6-core | |
| weight | About 6.2 kg |