Japanese AND halogen moisture analyzerThe high-precision and rapid moisture analyzer, manufactured with a brand new design concept and exquisite craftsmanship, is easy to operate and observe. With its excellent performance, it is widely used in industries such as food, tobacco, pharmaceuticals, petroleum, papermaking, feed, chemical industry, coatings, minerals, environmental protection, geology, etc. for rapid determination of material moisture content, while meeting the requirements for determining solid, particle, powder, gel and liquid moisture content
Japanese A&D halogen moisture analyzer/moisture meter
Detailed parameters:
| model | MS-70 | MX-50 | MF-50 | ML-50 |
| heat source | 400W halogen lamp | 400W halogen lamp | 400W halogen lamp | 400W halogen lamp |
| Weighing range | 71g | 51g | 51g | 51g |
| Reading accuracy | 0.0001g | 0.001g | 0.002g | 0.005g |
| water content/measuring accuracy | 0.001/0.01/0.1% | 0.01/0.1% | 0.05/0.1/1% | 0.1/1% |
| Temperature preset range | 30-200 degrees | 50-200 degrees | 50-200 degrees | 50-200 degrees |
| moisture content Display mode | Relative moisture content, absolute moisture content, wet dry ratio, wet dry ratio | Relative moisture content, absolute moisture content, wet dry ratio, wet dry ratio | Relative moisture content, absolute moisture content, wet dry ratio, wet dry ratio | Relative moisture content, absolute moisture content, wet dry ratio, wet dry ratio |
| Measurement method | Standard, automatic, timed, manual | Standard, automatic, timed, manual | Standard, automatic, timed, manual | Standard, automatic, timed, manual |
| Weighing disk size(mm) | Diameter 85 | Diameter 85 | Diameter 85 | Diameter 85 |
| External dimensionsW×D×H(mm) | 215 x 320 x 173 | 215 x320x 173 | 215 x 320 x 173 | 215x 320 x 173 |
| weight(make an appointmentKg) | 6.0 | 6.0 | 6.0 | 6.0 |
Japanese A&D halogen moisture analyzer/moisture meter
characteristic:
Four drying procedures
Standard drying: Heat up directly to the set temperature after startup.
Gradual drying: gradually raise the temperature to the set temperature after a preset time.
Step wise drying: Adopt different temperatures in stages according to time.
Quick drying: Heat rapidly at 200 ℃ for 3 minutes and then continue heating according to the set drying temperature.
Any combination of measurement and drying programs can fully meet the measurement requirements of different samples.
● InnovativeSRARapid and uniform halogen lamp heater technology
Adopting a straight tube halogen lamp and a uniquely designed SRA (Secondary Radiation Assistance Device) radiator to shorten measurement time and form a fast and uniform heater.
● High precision
The use of SHS fast and sensitive weighing sensors enables very accurate moisture content determination of very few samples under high-precision weighing.
Using sodium tartrate dihydrate as the standard for checking the accuracy of moisture content measurement
Sodium tartrate dihydrate is a chemical substance with a stable moisture content of 15.66%+0.3/-0.1, making it the most reliable for accuracy checks and providing reference values for measuring instruments.
● Heater temperature calibration (only applicable)MS/MX)
Optional temperature calibrator, calibration results can be output in GLP, GMP, ISO formats.
● StandardsWinCT-MoistureSoftware (only)MS/MX)Realize real-time graphic display
WinCT Moisture software is a moisture content analysis software designed specifically for graphical display. During measurement, it can display a graph of moisture content changes and use this graph to set measurement programs for different samples through computer-aided analysis.
● Measurement program,Measurement result storage function
Up to 20 sets of measurement programs can be stored, and different measurement programs can be called at any time for moisture content determination based on different samples. Therefore, it can achieve fast measurement and avoid setting operation errors (MF can store up to 10 sets, ML can store up to 5 sets). The measurement results can be stored in 100 sets (50 sets for MF and 30 sets for ML) and output through a computer or printer Completely avoiding human error.
● CompliantGLP/GMP/GCPandISOStandard, with date/Time,IDCalibration data and detection record output
Capable of recording and outputting calibration and measurement data to meet quality management and certification requirements.
● StandardsRS-232interface
Bidirectional communication with PC or connection to printer.
Clear and easy to observe large screen fluorescent display
The measurement program, set value, moisture content change rate, measurement status, data number, and other important information are displayed clearly at a glance.
● Easy to operate components
A disc handle designed ergonomically to avoid accidents such as burns when hot samples are placed or removed. The wing shaped handleThe heating cover is easy to open and close.
● Guarantee of low maintenance costs
Users do not need to stop using halogen lamps when replacing them, and the protected chamber is easy to clean (the lifespan of halogen lamps is about 5000 hours)
Five measurement programs
Standard mode: Measurement is automatically completed by setting high, medium, and low measurement accuracy.
Automatic mode: When the moisture content change rate is less than a set ratio, the measurement will automatically end.
Quick mode: In order to achieve rapid measurement, the first 3 minutes after startup are heated at 200 ℃, and then the measurement is completed according to the automatic setting.
Timer mode: Measurement is completed by setting the duration.
Manual mode: operate the measurement process by pressing the start and stop keys.
Standard accessories
Sample trays (20 for MS/MX/MF and 10 for ML)
● Disk handle (MS/MX/MF has 2, ML has 1)
Tweezers, sample spoon, and inspection sample (30g sodium tartrate dihydrate) (MS/MX/MF only)
● CD-ROM (MS/MX for WinCT Moisture, MF for WinCT)
MS/MX with RS-232 cable,
● Display film
Dust proof film (MS/MX/MF only)
● User manual
● Quick access card
● Power cord
● Two fuses
Optional accessories:
AX-MX-31 sample tray (100 pieces)
AX-MX-32-1 glass fiber sheet (100 sheets)
AX-MX-32-2 glass fiber sheet (100 sheets)
AX-MX-33 inspection sample (12 pieces of 30g sodium tartrate dihydrate)
AX-MX-34 halogen lamp tube
AX-MX-40 RS-232 cable
AX-MX-41 Calibration Weight (20g, OIML)
AX-MX-43 Temperature Calibrator (applicable only to MS/MX)