Overview of JMZ Stainless Steel Self priming Pump
The stainless steel self-priming pumps JMZ and FMZ are assembled with a new type of mechanical seal, which is safe and explosion-proof, and does not leak all year round. They are suitable for transporting various types of alcohol, beverages, dairy products, pharmaceuticals, gasoline, solvent oil, syrup, etc. at -35 degrees+80 degrees (the suction range will be significantly reduced above 40 degrees). JMZ and FMZ stainless steel self-priming pumps have the characteristics of compact structure, easy operation, small volume, light weight, stable performance, no need for bottom valves, and no need for injection during start-up. After replacing 3-4 parts, JMZ and FMZ stainless steel self-priming pumps can be used to transport concentrated slurry, acid, alkali, salt and other liquids. JMZ and FMZ stainless steel self-priming pumps
Performance range:
Flow rate is 3m3/h-100m3/h
Lift of 18m-14m
Caliber ranging from 25mm to 150mm
The significance of JMZ stainless steel self-priming pump model
Example: 40 J M Z-30 T
40: Imported caliber (mm)
J: J is the wine pump, F is the acid resistant pump
M: M represents high-quality stainless steel manufacturing
Z: Z is self-priming, T represents mobile, G is fixed
30: Head (m)
T: T: Refers to exports or flow rates with special requirements
Structural diagram of JMZ stainless steel self-priming pump
Performance parameters of JMZ stainless steel self-priming pump
model |
Caliber (mm) |
Flow rate (m3/h) |
Head (m) | Suction distance (m) | Motor (kw) | Rotation (r/min) |
model |
|
Import | produced by | |||||||
25JMZ-22 | 25 | 25 | 3 | 22 | 5 | 1.1 | 2900 | 25JMZ-22 |
25JMZ-30 | 25 | 25 | 3 | 30 | 6 | 1.5 | 2900 | 25JMZ-30 |
40JMZ-22 | 40 | 25 | 6 | 22 | 5 | 1.5 | 2900 | 40JMZ-22 |
40JMZ-30 | 40 | 25 | 6 | 30 | 6 | 2.2 | 2900 | 40JMZ-30 |
40JMZ-40 | 40 | 25 | 6 | 40 | 6 | 3 | 2900 | 40JMZ-40 |
50JMZ-22 | 50 | 40 | 12 | 22 | 5 | 2.2 | 2900 | 50JMZ-22 |
50JMZ-30T | 50 | 50 | 20 | 30 | 6 | 4 | 2900 | 50JMZ-30T |
50JMZ-40 | 50 | 40 | 12 | 40 | 6 | 4 | 2900 | 50JMZ-40 |
65JMZ-22 | 65 | 50 | 24 | 22 | 5 | 4 | 2900 | 65JMZ-22 |
65JMZ-30T | 65 | 65 | 30 | 30 | 6 | 5.5 | 2900 | 65JMZ-30T |
80JMZ-22 | 80 | 65 | 48 | 22 | 5 | 7.5 | 2900 | 80JMZ-22 |
80JMZ-30 | 80 | 65 | 48 | 30 | 5 | 7.5 | 2900 | 80JMZ-30 |
125JMZ-18 | 125 | 100 | 100 | 18 | 5 | 15 | 2900 | 125JMZ-18 |
Installation dimensions of JMZ stainless steel self-priming pump

model |
Supporting motor KW |
L |
L1 |
L2 |
L3 |
L4 |
B |
B1 |
B2 |
B3 |
H |
H1 |
H2 |
H3 |
D1 |
D2 |
D3 |
D4 |
n×ø d |
d1 |
d2 |
|||
n |
ø |
quantity |
ø |
quantity |
ø |
|||||||||||||||||||
25JMZ-22 |
1.1 |
670 |
400 |
115 |
265 |
110 |
260 |
215 |
215 |
150 |
110 |
234 |
120 |
200 |
100 |
75 |
100 |
75 |
4 |
12 |
4 |
12 |
4 |
12 |
25JMZ-30 |
1.5 |
700 |
430 |
130 |
264 |
107 |
280 |
240 |
240 |
155 |
130 |
282 |
107 |
210 |
100 |
75 |
100 |
75 |
4 |
14 |
4 |
12 |
4 |
12 |
40JMZ-22 |
1.5 |
720 |
430 |
140 |
273 |
118 |
280 |
240 |
240 |
155 |
130 |
265 |
124 |
225 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
40JMZ-30 |
2.2 |
730 |
430 |
132 |
268 |
113 |
280 |
240 |
240 |
155 |
130 |
280 |
123 |
237 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
40JMZ-40 |
3 |
820 |
500 |
128 |
320 |
120 |
330 |
290 |
240 |
180 |
132 |
305 |
127 |
250 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
50JMZ-22 |
2.2 |
760 |
430 |
151 |
282 |
127 |
280 |
240 |
240 |
155 |
130 |
280 |
143 |
232 |
140 |
110 |
130 |
100 |
4 |
14 |
4 |
14 |
4 |
14 |
50JMZ-30T |
4 |
860 |
510 |
138 |
315 |
135 |
330 |
290 |
290 |
190 |
132 |
283 |
135 |
228 |
140 |
110 |
140 |
110 |
4 |
14 |
4 |
14 |
4 |
14 |
50JMZ40 |
4 |
860 |
510 |
140 |
316 |
119 |
335 |
290 |
290 |
190 |
132 |
321 |
135 |
262 |
140 |
110 |
130 |
100 |
4 |
14 |
4 |
14 |
4 |
14 |
65JMZ22 |
4 |
875 |
510 |
163 |
335 |
135 |
360 |
290 |
290 |
190 |
132 |
305 |
148 |
250 |
160 |
130 |
140 |
110 |
4 |
14 |
4 |
14 |
4 |
14 |
65JMZ30T |
5.5 |
980 |
620 |
150 |
356 |
138 |
380 |
320 |
320 |
210 |
132 |
310 |
153 |
252 |
160 |
130 |
160 |
130 |
4 |
14 |
4 |
14 |
4 |
14 |
80JMZ22 |
5.5 |
980 |
620 |
150 |
340 |
160 |
380 |
320 |
320 |
210 |
132 |
305 |
160 |
250 |
190 |
150 |
160 |
130 |
4 |
14 |
4 |
17.5 |
4 |
14 |
80JMZ30 |
7.5 |
980 |
620 |
150 |
340 |
160 |
380 |
320 |
320 |
210 |
132 |
315 |
160 |
255 |
190 |
150 |
160 |
130 |
4 |
14 |
4 |
17.5 |
4 |
14 |
100JMZ22 |
11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
210 |
170 |
190 |
150 |
4 |
18 |
4 |
17.5 |
4 |
17.5 |
100JMZ30 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
210 |
170 |
190 |
150 |
4 |
18 |
4 |
17.5 |
4 |
17.5 |
150JMZ22 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
265 |
225 |
240 |
200 |
4 |
18 |
8 |
17.5 |
8 |
17.5 |
150JMZ30 |
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
265 |
225 |
240 |
200 |
4 |
18 |
8 |
17.5 |
8 |
17.5 |
200JMZ22 |
18.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
200JMZ30 |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
install
1. The pump can be laid on the foundation and the position of the foot bolts can be determined according to the 'Pump Appearance Installation Dimension Table'. But it's better to wait for the pump to arrive and then proceed with construction according to the size of the base.
2. The pump is installed on the foundation, and the level of the unit can be adjusted using shims. The level should also be checked with a spirit level, and the concentricity between the pump axis and the motor axis should be rechecked and adjusted. The difference between the outer circle, upper, lower, left, and right of the coupling should not exceed 0.15 millimeters using a knife edge ruler and a feeler gauge. The deviation between the end faces of the two couplings shall not exceed 0.2 millimeters.
3. Pumps should not bear the weight of pipelines, and the amount of pipelines should be supported by pipeline support equipment.
4. After installation, manually rotate the coupling to see if it is easy and flexible, and if there is any jamming phenomenon.
Disassembly and assembly
1 . Unscrew the four screws connecting the bearing body and pump body, and loosen the mechanical seal and pump cover at the same time.
2. Unscrew the impeller nut (turn right) to remove the impeller, key, and pump cover, and then remove the mechanical seal from the pump cover.
3. Use a slider to pull down the coupling, then remove the key and bearing end cover, and finally disassemble the shaft and bearing.
4. The assembly sequence of the pump should be reversed as described above.
When reinstalling the inlet coupling of the suction pump, please note that the water blocking valve should be facing forward to ensure a proper fit with the front of the water blocking valve and ensure self-priming effect (see the bottom right figure).
Installation of mechanical seals
1 . When replacing mechanical seals, attention should be paid to the specifications and models that match the original ones.
During the installation of mechanical seals, cleanliness should be maintained and the sealing components should not be knocked To prevent damage and destruction.
3 . When installing large and small sealing valves and dynamic and static rings, the surface should be coated with a layer of clean engine oil and transparent oil.
4. Install the static ring and large rubber ring into the pump cover, and then install them together on the shaft (note: the dynamic ring pin must be aligned with the drive hole of the impeller).
5. Push the ammunition seat and spring together to form a damaged assembly Using the spring seat surface as the force point, push it onto the main shaft, and the thrust should be compressed by the spring by 2-4mm before sliding on the shaft. If the spring is not yet compressed and can slide, it indicates that the fit between the dynamic ring and the main shaft is loose and the friction force is small. If the spring shrinks by more than 6mm and the dynamic and sealing rings still cannot slide on the shaft, it indicates that the fit is tight It should be checked whether the mechanical seal matches the original one.
Malfunctions and troubleshooting
fault |
cause |
Troubleshooting |
No liquid output |
Pump 1 is not fully filled with starting fluid 2. Miscarriage blockage of suction tube, extrusion tube or pump 3. Air leakage in the suction pipeline 4. The suction height exceeds the allowable range 5. The head used exceeds the design head 6. Transporting heat and active media 7 turned in the opposite direction 8. Mechanical seal leakage |
1. Fill the liquid again, and there is no need to fill it for the second startup 2. Remove debris 3. Maintenance and replacement of suction pipelines Reinstall the pump according to the allowed suction height 5. Re select the pump 6. Reduce suction or use reverse flow installation 7 Correction of steering 8. Repair or replace mechanical seals |
Long self-priming time |
1. Liquid temperature is too high 2. The suction pipe is too long 3 imported pipelines have Ω - shaped bends 4 outlets submerged in liquid |
The liquid temperature drops below 40 degrees Celsius 2. Try to shorten the pipeline as much as possible 3. Remove all Ω - shaped pipes 4. Connect the outlet to the atmosphere |
Insufficient traffic |
The depth of immersion of the suction pipe is not sufficient 2. The suction pipeline is too thin or blocked by debris Severe wear or corrosion of impeller 3 The sealing ring corrodes after severe wear and tear The gap between the impeller and the pump cover is too long |
1. Increase the immersion depth of the suction pipe Replace the appropriate pipeline and remove debris Replace the impeller with a new one Replace the sealing ring with a new one 5. Reduce gaps |
Insufficient head |
1. Severe corrosion of impeller 2. Incorrect motor configuration The gap between the impeller and the pump cover is too long |
1. Replace the impeller with a new one 2. Replace the motor 3. Reduce gaps |
Bearing overheating |
1. Insufficient or excessive lubricating oil The pump shaft and motor shaft are not concentric 3 bearings damaged 4. The quality of the bearings does not match |
Lubricating oil should be applied to 30-40% of the sealing chamber Adjust to make the pump shaft and motor shaft concentric Replace the shaft with a new one 4. Reduce noise bearings |
Severe vibration |
1. The pump shaft and motor shaft are not concentric Pump shaft bending |
Adjust to make the pump shaft and motor shaft concentric Replace the shaft again |
seal leakage |
Insufficient spring pressure Corrosion, wear, or scratches on the ends of the moving or stationary rings Corrosion and deformation of the sealing ring of the 3 dynamic rings 4 foreign objects or medium crystallization affect the main movement of the moving ring |
1. Adjust the compression amount of the spring or replace the spring 2. Repair or replace the dynamic or static ring Replace the sealing ring with a new one 4. Remove foreign objects or crystals from the medium |
motor overheating |
1. High specific gravity or high temperature of the liquid 2. The mechanical seal spring is adjusted too tightly 3. Low voltage 4. Poor assembly quality, some parts experience friction or the motor and pump shaft are not concentric |
1. Increase the motor size 2. Adjust the compression amount of the spring again 3. Increase voltage 4. Check the assembly quality and eliminate assembly faults |
JMZ Stainless Steel Self priming Pump Ordering Notice
1、 ① Stainless steel self-priming pump product name and model ② Stainless steel self-priming pump diameter ③ Stainless steel self-priming pump head (m) ④ Stainless steel self-priming pump flow rate ⑤ Stainless steel self-priming pump motor power (KW) ⑥ Stainless steel self-priming pump speed (r/min) ⑦ Stainless steel self-priming pump pressure [V] ⑧ Stainless steel self-priming pump suction stroke (m) ⑨ Whether the stainless steel self-priming pump comes with accessories for us to correctly select for you.
2、 If the design unit has already selected our company's stainless steel self-priming pump product model, please order directly from the sales department of Yangtze River Pump Industry Company according to the stainless steel self-priming pump model.
3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our technical experts from Yangtze River Pump Industry will review and control them for you.
Thank you for visiting our website of Yangtze River Pump Industry 【 www.yzj. cc 】. If you have any questions You can call us and we will do our best to provide you with high-quality service.