Hebei Xingchuan Environmental Protection Equipment Co., Ltd
Home>Products>JGGZ150-16 Automatic Cleaning UV Disinfector
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Intersection of North Second Ring Road, Zhonghua North Street, Xinhua District, Shijiazhuang City
Contact Now
JGGZ150-16 Automatic Cleaning UV Disinfector
UV sterilizer configuration: It mainly consists of a cylinder, UV lamp, ballast, sleeve, head, inlet, outlet, drain outlet, clamp, O-ring, indicator l
Product details

1Automatic cleaning UV sterilizerto configure:It mainly consists of a cylinder, ultraviolet lamp, ballast, sleeve, head, inlet, outlet, drain outlet, clamp, O-ring, indicator light, switch, power cord, etc. (High end optional: manual cleaning device, fully automatic cleaning device, UV intensity detector, time counter, sight glass)

2、 Classification: UV sterilizers are classified according to water flow statusPipeline type (overcurrent type) ultraviolet sterilizer, frame type (open channel type) ultraviolet sterilizer.

IIIAutomatic cleaning UV sterilizerWorking principle and configuration

1UV sterilizer sterilization process: Water enters through the equipment inlet and flows out through the outlet. Flowing between the device cylinder and the ultraviolet sleeve, after being irradiated with ultraviolet light, the DNA structure of bacteria and viruses is destroyed and unable to form, achieving the result of killing bacteria and viruses. UV sterilization mainly utilizes ultraviolet light with a wavelength of 254 nanometers. This wavelength of ultraviolet light can destroy the life core of a cell - DNA - even at a small dose of ultraviolet projection.

2The built-in ultraviolet lamp is imported with original packaging and uses ultraviolet lamps with wavelengths of 254 or 185.

UV Lamp Technology - Automatic Cleaning System

The most advanced Philips imported ultraviolet lamps or domestically produced inspection free lamps are equipped with mechanical automatic cleaning devices driven by compressed air, providing optional cleaning devices for low-voltage high-strength lamps, mercury lamps, and medium voltage lamps, which are linked with ultraviolet intensity detectors; Lamp lifespan of 12000-18000 hours and lower lamp replacement cost, with optional manual or automatic working modes.

3The built-in UV sleeve is made of high-purity quartz sand as raw material, with a UV transmittance greater than 94% and a pressure bearing capacity greater than 18 kilograms.

4High strength, constant ballast is selected for ultraviolet ballasts, ensuring the best actual output power and matching.

5To ensure that the actual output power of the ultraviolet lamp is at its optimal value, the ultraviolet sterilizer uses advanced constant and matched specialized ballasts, which can fully meet various environmental requirements.
6The overall design of the UV sterilizer conforms to the principles of fluid dynamics, and the material is food grade stainless steel 304 and 316L for customers to choose from. The interior of the equipment cylinder has undergone special treatment to ensure the best UV irradiation effect, while achieving the best sterilization and disinfection effect.

7All components of the UV sterilizer are certified for safety and environmental protection, and are made of food grade water related parts, fully complying with relevant national health and epidemic prevention requirements.
8UV sterilizers have a wide range of applications, including disinfection and sterilization of drinking water, as well as disinfection and sterilization of reclaimed water and sewage.

9The inlet and outlet of the ultraviolet sterilizer can be designed as top mounted, bottom mounted, and side opening.

10The UV disinfection control cabinet can be designed as an upper mounted, lower mounted, or split type.

11UV sterilizer inlet and outlet connection methods: flange, thread, quick clip.

12Ensure the interchangeability of components of the same model of ultraviolet sterilizer.

13Polish the surface of the ultraviolet sterilizer exposed to ultraviolet radiation.

14The arrangement of ultraviolet lamps ensures even distribution of ultraviolet intensity on the surface exposed to ultraviolet radiation.

15The specifications and inlet and outlet pipe diameters of the ultraviolet sterilizer shall be selected according to the table.

16According to the inspection requirements of this standard, disinfection products equipped with new light tubes must have a measured ultraviolet radiation dose of no less than 12000? W·S/cm。 (Should be filled with water), the UV radiation dose measured by a normally functioning sterilizer should not be less than 9000? W·S/cm。

17According to the usage conditions of this standard, when working at the rated disinfection water volume, the bacteriological indicators of the effluent meet the requirements of GB5749 "Sanitary Standards for Drinking Water".

4appearance

(1) The surface color of the equipment is *, with no flow marks, bubbles, or phenomena.

(2) The appearance of the equipment is neat and beautiful, without obvious hammer marks or unevenness. The panel instruments, switches, indicator lights, and signs are installed firmly and upright.

(3) The welding of the equipment casing and skeleton is firm, without deformation or burn through defects.

5Technical Parameter

Model: Processing capacity (T), Inlet diameter (cm), Power (w), Dimensions (cm)

JG-40 1.5-2 25 40×1 63×900

JG-55 3-4 32 55×1 63×1200

JG-75 4-5 32 75×1 63×900

JG-100 7-8 40 100×1 75×1300

JG-150 12-15 50 75×2 101×900

JG-240 22-25 80 120×2 159×1300

JG-360 32-35 100 120×3 159×1300

JG-400 40 100 100×4 159×1300

JG-500 50 125 100×5 219×1300

JG-720 70 125 120×6 219×1300

JG-1200 120 150 150×8 250×1660

JG-1350 150 200 150×9 300×1660

JG-1500 200 200 150×10 300×1660

JG-1800 250 250 150×12 300×1660