VIP member
Internet of Things wired water meter
Internet of Things wired water meter
Product details
LXSY-15~40

Product Introduction
This product is used to measure the total amount of drinking water flowing through the tap water pipeline and is wired(485/M-BUS bus)Transmit to collection devices and meter reading software. The characteristics of this product areBuilt in CPU, storage chip, and 485/M-BUS communication module. Just need to supply power when collecting water meter data, read the water meter character wheel code by the photoelectric tube, generate a number through CPU judgment, and output it through the 485/M-BUS bus.
Main technical parameters
Temperature level: T30
Pressure level: MAP10
Pressure loss level: Δp63
Sensitivity level of upstream flow field: U10
Sensitivity level of downstream flow field: D5
Climate and mechanical environment level: Grade B
Electromagnetic environment level: E1 level
Accuracy: Class B
Maximum allowable error: The maximum allowable error in the low zone from including the minimum flow rate (Q1) to excluding the boundary flow rate (Q2) is ± 5%
·The maximum allowable error in the high zone, including flow rate (Q2) and overload flow rate (Q4), is (cold water meter) ± 2%
| Nominal diameter mm |
Accuracy level |
Common traffic Q3 |
Minimum reading | Maximum reading |
| m3/h | m3 | |||
| 15 | Q3/Q1=80、63、50 Q2/Q1=1.6 Accuracy level: Level 2 |
2.5 | 0.001 | 9999 |
| 20 | 4 | 0.001 | 9999 | |
| 25 | 6.3 | 0.001 | 9999 | |
| 40 | 16 | 0.001 | 99999 | |
Signal wiring
| Line color type |
red thread | Black line | White (yellow) line | Blue (green) line |
| 485/bus | Power supply positive | Negative power supply | 485+ | 485- |
| meter-bus | Regardless of polarity | Regardless of polarity | ||
Dimensions and approximate weight
| model | caliber | Long L | Width B | High H | Connecting thread | Weight kg |
| mm | ||||||
| LXSY-15E | 15 | 165 | 98 | 104 | G/4B | 1.5 |
| LXSY-20E | 20 | 190 | 98 | 106 | G1B | 1.7 |
| LXSY-25E | 25 | 230 | 103 | 112 | G1¹/4B | 2.4 |
| LXSY-40E | 40 | 245 | 124 | 147 | G2B | 4.8 |
Electrical parameters
| Power Supply | DC 7.5-15V (RS485 bus), DC 24-36V (M-BUS bus) |
| electric current | Normally not powered, the bus RS485 (0.6~0.8) mA is used for data acquisition Bus M-BUS (1.0~1.3) mA |
| Communication method | RS485/M-BUS communication |
| Communication Protocol | Communication protocols: DL/T645 protocol (consistent with meter protocol), CJ/T188-2004 protocol, MODBUS-RTU protocol |
Online inquiry