1、 Overview
With the advancement of modernization, various industries have increasingly high requirements and dependence on electricity, and safe and efficient electricity use has become one of the most important components of enterprises. For units such as power supply, banking, securities, communication, and customs that require real-time data processing, the management of power distribution rooms is particularly important. Once the system fails, the economic losses caused are incalculable. At present, many managers of power distribution rooms have to adopt 24-hour dedicated personnel on duty, regularly inspecting various line equipment. This not only increases the burden on managers, but also more often than not, safety hazards cannot be eliminated in a timely manner, and electricity waste cannot be predicted. This is undoubtedly a disadvantageous factor for the safe operation and management of electricity.
It is precisely to solve the above problems that the transformer and distribution monitoring system software uniformly monitors various intelligent devices in the distribution room, provides beautiful and friendly monitoring screens, and automatically alarms when abnormalities are detected, ensuring the reliable operation of the system. Reduced the burden on maintenance personnel, improved the reliability of the system, and achieved scientific management of the distribution room.
The software of the power distribution monitoring system can timely and accurately know the situation of each power circuit, avoiding the phenomenon of "running, emitting, dripping, and leaking" by power managers. At the same time, it also provides guarantees for modern management of power transformation and distribution, including safety assurance, economic operation, load analysis, peak shaving and valley filling, peak valley time of use billing, economic accounting, reasonable scheduling, and timely fault handling.
2、 Composition
Data collection: Collect and upload data from on-site equipment.
Data processing: Ensure the integrity of data and repair it.
Data analysis: The analysis results provide a basis for judging the safe and economical operation of electricity.
Typical structural diagram
3、 Function List
Serial Number | module | Sub-module | functionality | notes |
1、 Basic functions | ||||
1 | Wiring diagram | Real time monitoring of wiring diagrams, remote signaling, telemetry, remote control and other data | ||
2 | Working condition diagram | Real time monitoring of communication status, etc | ||
3 | query | Real-time data | Real time value | Real time data query display |
Real time charts | Real time data running curve display | |||
Daily online monitoring | Daily hourly data curve report display | |||
HISTORICAL DATA | historical value | Historical data query display | ||
Historical chart | Historical data curve report display | |||
statistical data | Switching frequency | Statistical analysis of switch frequency | ||
Exceeding the limit times | Statistical analysis of exceeding limit times | |||
4 | operations analysis | operations analysis | daily newspaper | Daily hourly data curve report analysis |
weekly report | Analysis of Weekly Data Curve Report | |||
Monthly report | Analysis of Monthly Data Curve Report | |||
Quarterly report | Analysis of Seasonal Data Curve Report | |||
annual report | Analysis of Annual Data Curve Report | |||
comparative analysis | Time benchmarking | Comparative analysis of data from the same device at different times, displayed in chart format | ||
Equipment benchmarking | Comparative analysis of data from different devices at the same time, displayed in chart format | |||
5 | power management | power management | Jianfeng Pinggu | Trend analysis of peak and off peak proportions of electricity and electricity bills, displayed in chart format |
Electric energy audit | Comparative analysis of electricity consumption (coal consumption) per unit product by category and sub item | |||
Regional electricity | Energy consumption status of classified sub units | |||
Team assessment | Power consumption and relative theoretical power consumption of each team | |||
Power consumption | Can consume | Display the daily hourly electricity consumption status in chart format | ||
Weekly electricity consumption | Display weekly electricity consumption status in chart format | |||
Monthly electricity consumption | Display monthly electricity consumption status in chart format | |||
Seasonal electricity consumption | Display quarterly electricity consumption status in chart format | |||
Annual electricity consumption | Display the annual electricity consumption status in chart format | |||
6 | Energy Saving Assessment | Monitor Point | Evaluate and analyze the power factor of monitoring points, the rated load percentage of actual load points, and the daily load rate of electricity consumption, and display the results in the form of charts and graphs | |
transformer | Evaluate and analyze transformer efficiency, power loss, load factor, power balance diagram, power motion diagram, etc., and display the results in the form of charts and graphs | |||
line | Evaluate and analyze line losses, power balance diagrams, power motion diagrams, etc., and display them in a graphical format | |||
motor | Analyze the current running time, cumulative running time, maintenance cycle, stopping time, stopping times, etc. of the electric motor, and display the results in the form of charts and graphs | |||
quality | Analyze the harmonic content and voltage distortion rate of monitoring points, and display the results in the form of charts and graphs | |||
7 | Environmental monitoring | Environmental monitoring | Real time monitoring of environments such as smoke detection, water immersion, temperature and humidity | |
8 | Graphic invoicing | Graphic creation operation ticket, printing, saving, etc | ||
9 | Event Query | Event Query | real-time event | Real time event alerts, push notifications, and queries |
historical event | Historical event query, which can be queried by time, event type, etc | |||
10 | Report Query | Excel report template for querying, exporting, and printing daily, monthly, and annual reports | ||
11 | ADVANCED | ADVANCED | Ticket warehouse management | Operation ticket library query, printing and other management |
12 | communication management | |||
13 | system management | system management | equipment management | Equipment file management, equipment type management |
Variable management | Variable management | |||
User Management | User permission allocation and other management | |||
parameter configuration | Load configuration, energy consumption configuration, rate configuration, rate type configuration, global unit conversion | |||
2、 Extended functionality | ||||
1 | Video monitoring | |||
2 | ADVANCED | ADVANCED | PDR | |
Fault recording | ||||
Fixed value management | ||||
3 | web interface | C/S and B/S architectures coexist, supporting WEB publishing. Real time system data, monitoring screens, historical data, etc. can be viewed through a WEB browser on the local area network or external network. | ||
4 | APP interface | Provide an APP client that allows users to view real-time system data, monitoring screens, historical data, and more anytime and anywhere on their mobile phones. | ||
5 | Protocol development | Special non-standard protocol development |