Intelligent integrated flame detection system
Brief description: The FS-100 intelligent integrated flame detector is based on microprocessor and bus technology. It detects the target flame light s
Product details
Introduction to Intelligent Integrated Flame Detection System
The FS-100 intelligent integrated flame detector is based on microprocessor and bus technology. It detects the target flame light signal through the installation of IR (infrared) sensors or UV (ultraviolet) sensors to determine the presence/absence of the burner target flame, ensuring that the fuel supply is stopped when the boiler is extinguished. This system is widely used in industries such as power generation, refining, chemical, steel, cement, etc., and is suitable for continuous detection of single or multi fuel burner flames in various industrial furnaces such as power plant boilers, fluidized bed boilers, coal powder boilers, and kilns.
Characteristics of Intelligent Integrated Flame Detection System
Technical indicatorsSelf checking and self-learning functions;
Fault alarm, password protection, frequency selection function;
Integrated structural design, easy to install and debug, with minimal maintenance;
Install PTFE professional insulation material to improve equipment temperature resistance parameters and extend equipment service life;
Using high-performance photosensitive devices, spectral response range: UV type: 190nm-380nm, IR type: 700nm-1700nm;
Equipped with network functionality: capable of remote online adjustment and parameter setting;
A professional engineering installation service guidance team ensures that fire detection does not peek;
Can store 8 sets of files, suitable for different loads, fuels, and combustion technologies
1Conduit components
Perspective: Coal Fire Inspection 7o~10oOil and fire inspection 5o~7o;
Environmental temperature: (-40~600)℃
Spectral range: (190-380) nm (UV type), (700-1700) nm (IR type)
Transmittance:> 85%
Catheter structure: direct view and fiber optic
2Flame detector
Display interface: 8-character LED;
Analog output: (4~20)mA ;
Environmental temperature: (-40~85)℃;
Environmental humidity: (0-95)% relative humidity, non condensing;
Protection level: NEMA 4X IP66
Contact output: flame relay (normally closed), fault relay (normally closed);
Contact capacity: 30VDC/2A, 125VAC/0.6A;
Maximum load: 750 Ω;
Input power supply: 24VDC ± 10% 0.35A ;
Installation method: threaded connection method;
Shell weight: approximately 1.8kg;
3Cooling/blowing air
Traffic: (5~15)SCFM ((141.5~424.5)Nm /min) ;
Pressure: 6Kpa;
Cooling air source: clean and dry cold air source
to configure
The system consists of duct components, flame detectors, local junction boxes, power cabinets, and cooling air systems.