Jiangsu Wanxun Instrument Co., Ltd
Home>Products>Integrated nozzle flowmeter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13852268678
  • Address
    Gong'er Road, Jinhu Industrial Park, Jiangsu Province
Contact Now
Integrated nozzle flowmeter
The integrated nozzle flowmeter is a new type of flow instrument that optimizes the assembly of traditional throttling devices and intelligent differe
Product details

Product Introduction

The integrated nozzle flowmeter is a new type of flow instrument that optimizes the assembly of traditional throttling devices and intelligent differential pressure transmitters, which complies with the national standard GB/T2624-2006 and the international standard ISO5167:2003. Users do not need to install additional pressure pipes when using the flowmeter. They only need to install the flowmeter on the pipeline to use it. It can be widely used for flow detection and trade measurement of various fluids such as steam, natural gas, hot water, gas, and liquid. The integrated throttling flowmeter not only has the advantages of good adaptability to traditional throttling flowmeters (applicable to liquids, gases, and steam), no moving parts, no need for real flow calibration (geometric measurement methods can be used for dry calibration), and measurement accuracy supported by national (international) standards, but also has the following advantages:


Due to the overall assembly of the instrument, measurement errors caused by on-site installation of the instrument are eliminated, and the failure rate is greatly reduced, making it a maintenance free instrument

The pressure conduit of the differential pressure transmitter is greatly shortened, which improves the dynamic performance of the instrument

Equipped with ISA1932 nozzle throttling components as standard, the flow meter has less pressure loss, longer service life, and an increased legal calibration cycle of 4 years

Specially suitable for measuring steam flow: no insulation or heat tracing is required when measuring steam. The ISA1932 nozzle throttle is more resistant to the impact and wear of high velocity steam, is not easily deformed, and has long-term reliable accuracy. And due to the absence of a condensation tank, there is no condensation water, completely eliminating the unpredictable measurement errors caused by the liquid level difference of condensation water on the positive and negative pressure sides in traditional steam throttling devices.

The integrated nozzle flowmeter can be used in conjunction with various flow display instruments and systems.

Wide range flow measurement with a range ratio of 10:1 within 1.0% accuracy

Equipped with dual differential transformers, wide range universal gas and steam flow metering with a range ratio of 20:1 within 1.0% accuracy

Bidirectional flow metering

Energy metering of steam, coal gas, natural gas, etc

Humidity compensation for wet gases, measuring the flow rate of wet gases and the dry part flow rate of wet gases separately

Adopting real standard coefficient compensation technology to achieve high-precision flow measurement (uncertainty ≤ 0.25%)

Installation diagram of integrated nozzle flowmeter (throttling flowmeter)


www.jhwxyb.com

Selection of Reynolds number range



ISA1932 nozzle
standard orifice plate
7 × 10^4 ≤ ReD ≤ 10^7 (0.3 ≤β≤ 0.44)

ReD ≥ 5000(0.20 ≤β≤ 0.45)

ReD ≥ 10000( β >0.45)
Corner joint pressure measurement
2 × 10^4 ≤ ReD ≤ 10^7 (0.44 ≤β≤ 0.80) ReD ≥ 1260 β^2 D flange taps

Technical Parameter

Caliber (mm) DN25~DN1000
measured media Liquid, gas, steam
temperature range -40 ℃~ 600 ℃
Pressure Range 1.0MPa~25.0MPa
Throttle Standard orifice plate, ISA1932 nozzle, long diameter nozzle, 1/4 circular orifice plate, eccentric orifice plate, circular orifice plate, conical inlet orifice plate, bidirectional flow orifice plate
Pressure collection method Corner joint pressure measurement, flange pressure measurement, radial distance pressure measurement
differential pressure transmitter EJA110A 、 EJA120A 、 3051CD 、 3095CD

Scope and

Uncertainty

Equipped with ordinary secondary instruments

WXXMJA-9000

3:1 10: 1 (Single variation) 20: 1 (Double Differential Transformer)
± 1.0%

± 1.0%

± 0.25% (real flow calibration)

± 1.0%

± 0.25% (real flow calibration)
Material of throttling element 1Cr18Ni9Ti 、 SUS316 、 other
Material of clamping component 1Cr18Ni9Ti 、 SUS316 、 20 # steel, 12Cr1MoV, 15CrMo, other
power supply Transmitter section: 24VDC (20mA); Flow display device: 220VAC/50Hz or 24VDC
explosion-proof Ia Ⅱ CT2-T5 intrinsically safe explosion-proof
Transmitter output signal 4-20mA (load resistance ≤ 500 Ω); HART digital signal
protection grade IP65
ambient temperature -20 ℃~55 ℃ (please declare if it exceeds this range)
ambient humidity 45% ~ 85 %
atmospheric pressure 86 ~ 106kPa
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!