Using indoor air heating in conjunction with battery high-temperature testing fixtures and battery charging circuit control, simulate battery charging and storage in high-temperature environments, and test battery safety performance and high-temperature resistance
advantage
- ① 7-inch true color LCD touch screen+PLC programmable controller+temperature module control system, high precision, Chinese operation interface, simple operation, easy use and maintenance
- ② Affordable prices and budget savings for users
- ③ Install battery testing fixtures inside the test chamber for easy use
- ④ Bottom mounted casters that can be moved according to their placement position
- ⑤ Electronic temperature sensor, high precision, low maintenance
- ⑥ Users can meet the special requirements of the laboratory by processing the types of inner and outer walls according to their needs
- ⑦ Glass woven cotton filling warehouse
specifications
Model (Mode) | CZ-1200CY |
---|---|
Nominal internal volume | 960L |
Effective size of inner box | 1500x1750x400mm(WxHxD) |
Carton size | Approximately 2100x2135x785mm (WxHxD) |
weight | About 500kg |
temperature range | RT+10℃~120℃ |
heating rate | RT->120℃≤40min |
Control accuracy | Temperature deviation ± 1 ℃; The temperature uniformity is measured at points with a temperature difference of less than ± 3 ℃ (according to GB/T 11158-2008); Temperature resolution 0.1 ℃ |
Machine power | AC 380V 50Hz 15.2KW, maximum current of 23A, maximum power during the heating stage of the machine 15.2KW, constant temperature 85 ℃, power ≤ 3.5KW |
Power supply conditions and sources | AC 380V three-phase four wire+protective grounding |
Voltage allowable fluctuation range: ± 10% V | |
Allowable frequency fluctuation range: (50 ± 0.5) Hz | |
TN-S power supply or TT power supply | |
The grounding resistance of the protective grounding wire is less than 4 Ω | |
Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must independently control the use of the equipment | |
Test environment conditions | The ambient temperature is+25 ℃ and the relative humidity is ≤ 85% R.H |
control panel | 7-inch touch screen controller, RS-232 communication interface, over temperature protector, emergency stop button switch, control power switch, buzzer alarm, exhaust switch |
Inner box structure | Heating tube, air conditioning type, coil fan, indoor over temperature protection sensor, air guide plate |
Sample limitations | This testing machine equipment prohibits the testing of samples containing flammable, explosive, and volatile substances; Testing and storage of samples for storing corrosive substances, testing and storage of samples for storing organisms, testing and storage of samples for storing strong electromagnetic emission sources |