VIP member
High and low temperature test chamber for battery pack
High and low temperature test chamber for battery pack
Product details
model | SC-A-225 | SC-A-408L | SC-A-800L |
---|---|---|---|
Internal dimensions WxHxD (cm) | 50x75x60 | 60x85x80 | 80*100*100 |
External dimensions WxHxD (cm) | 78*171*137 | 860*151*187 | 130*196*167 |
temperature range | -70℃~+100℃(150℃) (A:+25℃ B:0℃ C:-20℃ D:-40℃ E:-50℃ F:-60℃ G:-70℃) |
||
Humidity range | 20%~98% R.H. (10%~98% R.H/5%~98% R.H are special selection conditions) | ||
Temperature and humidity analysis accuracy/uniformity |
±0.1℃; ±0.1%R.H./ ±1.0℃; ±3.0%R.H. |
||
Temperature and humidity control accuracy/fluctuation |
±1.0℃; ±2.0%R.H./ ±0.5℃; ±2.0%R.H. |
||
Heating/cooling time | About 3.0 ℃/min; About 1.0 ℃/minute (a decrease of 2-10 ℃ per minute is a special selection condition) | ||
Internal and external materials | Cold rolled steel plate with baking paint treatment, inner box SUS 304 # made of stainless steel | ||
Insulation material | High temperature resistant and high-density vinyl chloride acetate foam insulator material | ||
Cooling system | Air cooled/single-stage compressor (-20 ℃), air-cooled/two-stage compressor (-40 ℃~-70 ℃) | ||
Protector | Non fuse switch, compressor overload protection switch, refrigerant high and low voltage protection switch, over humidity and over temperature protection switch, fuse, fault warning system | ||
accessory | Recorder (optional), viewing window, 50mm test hole, PL box light, partition, dry wet ball gauze | ||
controller | South Korea "TEMI" or Japan's "OYO" brand can be chosen | ||
compressor | French "Taikang" brand | ||
power supply | Φ 380VAC±10% 50/60Hz |
Online inquiry