High and low temperature impact test chamber/cold and hot impact test chamber
Purpose: This equipment is mainly used to test the performance of products during storage, transportation, and use in climate environments with sudden
Product details

Purpose:

This equipment is mainly used to test the storage, transportation, and performance of products in rapidly changing climate environments with high and low temperatures
The performance during use is mainly used for electrical and electronic products, components, parts, metal materials, and their applications
Simulate adaptability tests under climate conditions with instantaneous temperature changes at high and low temperatures, and test the physical and other related properties of the product:
1.During the development phase, it is used to expose defects in all aspects of the trial product and evaluate the reliability of the product to meet predetermined indicators;
2.Provide information for monitoring the production process during the production phase;
3.Reliability assessment or acceptance of standardized products;
4.Expose and analyze the failure patterns and related failure modes and mechanisms of products under different environmental and stress conditions;
5.To improve product reliability, develop and improve reliability testing plans, and provide a basis for users to select products.
Main parameters

model
VTS70
VTS110
VTS150
VTS200
VTS250
VTS300
Studio ruler
Inch(mm)
deep
370
370
500
670
670
670
wide
410
650
650
650
810
970
tall
460
460
460
460
460
460
Overall dimensions
mm
deep
1570
1570
1700
1870
1870
1870
wide
1470
1710
1710
1710
1870
2030
tall
1860
1860
1860
1860
1860
1860
Impact temperature range
-10, -20, -30, -40, -55, -65~+150
Preheating and pre cooling temperature range
Preheating:+60~+200 Pre cooling: -80 ℃~0
Exposure Time
High temperature exposure: 30 minutes Low temperature exposure: 30 minutes Environmental exposure: 5 minutes
temperature deviation
±2℃
Temperature conversion time
5s
Temperature response time
5min
Environmental temperature for use
+535
material
material
shell
Double sided galvanized steel sheet,Surface spraying treatment
inner body
stainless steel plateSUS304
adiabatic
Rigid polyurethane foam+fiberglass
tune
section
device
heater
Nickel chromium alloy electric wire heater
fan
centrifugal fan
compressor
Low noise piston compressor
Cooling method
Mechanical compression single-stage refrigeration(air cooling/water cooling)
Mechanical compression cascade refrigeration(air cooling/water cooling)
refrigerant
R404A
R404A/R23
control
manufacture
device
monitor
8inch,640x480dot matrix,TETTrue color touch screen
Operation mode
Fixed value method, program method
Setting method
Chinese menu and touchscreen input
Program capacity
editable:20A program,Maximum for each program50step,Can be set20A cycle(Maximum per cycle step9999Next cycle)fixed, tenA program can be linked,Can achieve infinite operation.
set the scope
temperature:Adjust according to the temperature range of the equipment(upper limit+10,lower limit-10;Preheating upper limit+220,lower limit-85)
display resolution
temperature:0.1;time:0.1min
input
thermocouple
communication function
(select)RS-485interface,Capable of local and remote communication(Centralized monitoring software is requiredRS-485/RS-232Conversion, requires occupationPCMachine'sCOM
Mouth andUSBOne mouth each)Can be connected simultaneously at most16Equipment, maximum cumulative cable length800m,PCSoftware usage environment:IBM PCDual use machine,PIIaboveCPU,128MThe above memory,Simplified ChineseWindows2000Or Simplified ChineseWindowsXPoperating system.
Control method
Anti integral saturationPID
Curve recording
Equipped with battery protectionSRAM,Can save the set values, sampling values, and sampling time of the device, and can be observed by sliding in real-time with finger touch on the screen;The default maximum storage time is60sky(The sampling period is1.5min),The formula for calculating sampling time is as follows:If the sampling period is set tot/min,storage timed=((65536xt)/60)/24(sky).
data collection
*Screen interface curve output--Directly save the curved interface on the touch screen or any interface requested by the customer as*.bmpSave image toUPrint the curved interface on the touch screen or customer requirements directly from the disk or printer(Need to modify the interface software)Any interface;
*USBfunction--match1GUSB flash drive1a.During the experimentUInsert the disk into the controllerUSBOn the interface,The experimental data will be automatically recordedUInside the plate,Save as*.csvdata file(Non curve chart),The sampling period can be set on the screen.useEXCELWait for the software to open and process;
*Connect to printer(select):-configure printer,The test date can be printed by setting the number of printing times according to time,set temperature,Actual measured temperature,Set humidity,Measured humidity;
*pick upPCmachine(select):--Through centralized monitoring software,Can record experimental data,inPCAutomatically display as a curve in the machine,Can be printed directly,Unrestricted recording time.The file size depends on the hard drive capacity.PCIt can also be used as an operating terminal,Realize remote monitoring.
Supplementary functions
Fault alarm and cause, processing prompt function;A fail-safe mechanism;Upper and lower limit protection function;timer function(Automatic start and automatic stop operation).
power supply
AC380(1±10%)V (50±0.5)Hzthree-phase four-wire+Protect the ground wire
Power (KW)
Depending on temperature
Standard Configuration
Electric heating film glass observation window1a,cable hole(50)1a,sample holder2set,lighting lamp(fluorescent lamp)1a,caster6a,Sample power control terminal1a.
safety device
Residual Current Circuit Breaker,Fan overheat protection,Compressor overpressure, overheating, phase sequence protection, overtemperature protection,Temperature fuse,Dry burning protector, etc.
meet the standard
GB10589、GB10592、GB11158、GB/T5170.2、GB2423.1-2008、GB2423.2-2008