TG-61321D high and low temperature impact test chamberPurpose of instrument and equipment:
The high and low temperature impact test chamber is used to test the degree to which material structures or composite materials can withstand continuous environments of extremely high and low temperatures in an instant, in order to test the chemical changes or physical damage caused by thermal expansion and contraction in the shortest possible time. Applicable objects include automotive electronics/Components, LED/LCD/PDP display lighting, electronics and electrical engineering, instrumentation, new energy/electronic components/appliances, plastics/rubber/films, scientific research/quality inspection/universities/medical equipment, PCB/FPC/HDI/MPCB/IC and other industry materials can serve as a basis and reference for product quality verification or improvement.
TG-61321D high and low temperature impact test chamberOverview of Construction:
thermal shock chamber/The hot and cold high temperature and low temperature test chamber is also a high and low temperature impact test chamber, so the three slot hot and cold impact test chamber is also a three slot high and low temperature impact test chamber. The main structure consists of three slots (high temperature slot, low temperature slot, and product slot). The high temperature slot is used for producing and storing high temperatures, the low temperature slot is used for producing and storing low temperatures, and the product slot is used to provide customers with space for placing products. The principle of impact is to use gas to expel the hot and cold temperatures of high and low temperature tanks into the space where the product tank is placed to complete the experiment.
TG-61321D high and low temperature impact test chamberApplicable to standards:
1:GB/T 10592-2008 Technical Conditions for High and Low Temperature Test Chambers;
2:GB/T 2423.1-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test A: Low temperature (IEC 60068-2-1:2007, IDT);
3:GB/T 2423.2-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test B: High temperature (IEC 60068-2-2:2007, IDT);
4:GB/T 2423.22-2012 Environmental Testing Part 2: Test Methods Test N: Temperature Variation (IEC 60068-2-14:2009, IDT);:
5:GJB 150.3-86 Environmental Test Methods for Military Equipment Part 3 High Temperature Test;
6:GJB/T 150.4-2009Environmental testing methods for military equipment 第4 parts of low temperature test;:
7:GJB/T 150.5-86 Environmental Test Methods for Military Equipment Part 5 Temperature Shock Test.
8: GJB150.5-86 temperature shock test;
9: GJB360.7-87 Temperature shock test;
10: GJB367.2-87 405 temperature shock test;
11: GB11158-2008 Technical Conditions for High Temperature Test Chamber
12: GB10589-2008 Technical Conditions for Low Temperature Test Chamber
TG-61321Cthermal shock chamberProduct Features:
1: The new generation of high and low temperature impact test chamber produced by Taigui Instrument(3 boxes), the box structure, refrigeration system, and control technology have undergone significant technological reforms, resulting in more reliable operation and easier maintenance.
2:The refrigeration machine adopts知名genuineImportTaikangorBizelle.
3:controlThe system adoptsColor touch screen display in both Chinese and EnglishTouch-toneoperation,The appearance is simpler and more elegant,The operation setting is simple.
4: The high and low temperature impact test chamber is divided into two box type juvenile impact and three box type static impact according to the special characteristics of the test sample. This product can be used for both cold and hot shock tests, as well as for individual high or low temperature use.
5:The test sample is kept in a static state to reduce mechanical impact on the sample. Its temperature conversion is achieved by opening (closing) different air doors through a pneumatic system. It has test holes, can be charged, has signals, and has a gas source for testing. achievableAdjustable from 5 ℃/min to 30 ℃/min.
6High and low temperature impact test chamber equippedSD card storage, USB output, computer connected printing, large cabin with paperless recording and other optional features.
7: Box processingIt is processed and formed using CNC machine tools, with a beautiful and elegant appearance, and adopts a non reactive handle for easy operation.housingadoptHigh quality carbon steel platePhosphating electrostatic spraying treatmentOr (optional)SUS304 stainless steel matte surface line hairline treatment,All internal materials are made ofSU304 high-grade stainless steel material.
8: Equipment for high and low temperature impact test chamberLarge observation window attachedinternational brandThe lighting fixtures keep the inside of the box bright and use tempered glass embedded in the heating body to observe the condition of the box clearly at all times.
TG-61321Dthermal shock chamberTechnical Specifications:
Device Model |
Studio size (mm) |
Dimensions (mm) |
volume |
note |
Total power of the power supply |
|
TG-61321A |
350x350x400 |
1500x1600x2020 |
50 L |
Experimental volume can be customized according to customer requirements |
380v/8kv |
|
TG-61321B |
400x500x500 |
1500x1700x2020 |
100 L |
380v/8.5kv |
||
TG-61321C |
500x500x600 |
1600x1700x2100 |
150 L |
380v/9.5kv |
||
TG-61321D |
750x600x500 |
1700x2650x1900 |
225 L |
380v/9.5kv |
||
TG-61321E |
800x800x800 |
2500x2500x2100 |
512 L |
380v/13kv |
||
TG-61321F |
1000x1000x1000 |
3500x3500x2200 |
1000 L |
380v/15kv |
||
TG-61321G |
1500x1000x1000 |
4200x3800x3800 |
1500L |
380v/20kv |
||
temperature |
high-temperature chamber |
RT~200℃ |
||||
Low-temperature chamber |
RT~-70℃ |
|||||
Impact temperature range |
-40℃、-50℃、-60℃~ 120 ℃ and 150 ℃ can be selected as needed |
|||||
Temperature fluctuation ≤ ± 0.5 ℃ |
Temperature uniformity ≤± 2 ℃ |
Noise dB ≤ 65 |
||||
ramp rate |
warm up |
60min/RT~200℃ |
||||
cool down |
60min/0~70℃ |
|||||
Experimental method |
temperature conversion |
Pneumatic air door switching, ventilation type |
||||
Valve switching time |
≤5s |
|||||
Temperature recovery time |
≤5min |
|||||
refrigeration |
system |
French fully enclosed Taikang compressor/or Bizelle compressor, single/stacked refrigeration |
||||
refrigerant |
1:R~404A 2: R-23 (fluorine free) 3; Tai Gui R&D refrigerant (stable and excellent) |
|||||
cooling |
Air cooling/water cooling optional |
|||||
sensor |
temperature |
A-grade platinum resistor A (PT100) or digital sensor (optional) |
||||
humidity |
A-grade platinum resistor A (PT100) or digital sensor (optional) |
|||||
control |
Original temperature control instrument, easy to operate, convenient to set, control accuracy of 0.01 ℃, exceeding 1200 programming segments. |
|||||
test hole |
Used for external testing of power or signal lines |
|||||
Standard Configuration |
SUS304Board storage rack (second floor) |
|||||
safety protection |
Compressor overheating, overpressure, overtemperature, fan motor overheating, overall equipment under phase/Reverse phase overall equipment timing, leakage protection, overload and short circuit protection |
|||||
note |
Tai Gui Company can customize products according to customer requirements. |
|||||
