VIP member
High and low temperature humidity test chamber/constant temperature and humidity test chamber
Application: Used in the semiconductor industry:
Product details
Purpose:
Applied to the semiconductor industry:
Widely used forBGA/CSP(PBGA/CABG/LFBGA/SBGA/TABGA/FilipChip)The manufacturing process of packaging, etc;
Widely used inCSPEpoxy resin hardening, used in precision electronic components and wafer baking engineering;
Widely used forFPCThe manufacturing process of flexible circuit boards.
Product features:
This device has obtained two patents, with exquisite structure and low energy consumption, making it the most high-performance device in China.
Main parameters:
|
model
|
VNT91
|
VNT216
|
VNT512
|
VNT1000
|
|
|
Studio Size
(mm)
|
deep
|
450
|
600
|
800
|
1000
|
|
wide
|
450
|
600
|
800
|
1000
|
|
|
tall
|
450
|
600
|
800
|
1000
|
|
|
External dimensions
(mm)
|
deep
|
950
|
1100
|
1300
|
1500
|
|
wide
|
950
|
1100
|
1300
|
1500
|
|
|
tall
|
1450
|
1600
|
1800
|
2000
|
|
|
temperature range
|
R·T+10℃~200℃(300℃)
|
||||
|
Heating time (no load)
|
≤40min
|
≤60min
|
≤60min
|
≤70min
|
|
|
Residual oxygen concentration inside the box ≤100ppm,Consuming high-purity inert gas (such asN2)Traffic volume
|
≤20L/min
(≤50mindrop to)
|
≤50L/min
(≤50mindrop to)
|
≤100L/min
(≤50mindrop to)
|
≤200L/min
(≤50mindrop to)
|
|
|
≤7L/min
(Concentration maintenance)
|
≤15L/min
(Concentration maintenance)
|
≤30L/min
(Concentration maintenance)
|
≤60L/min
(Concentration maintenance)
|
||
|
External material
|
Double sided galvanized steel plate, surface spray treatment
|
||||
|
Inner box material
|
SUS304Mirror stainless steel
|
||||
|
Lead hole
|
1 piece with a diameter of 50mm, located on the back of the box
|
||||
|
Controller display screen
|
5.7Inches,STNcolorLCDtouch screen
|
||||
|
display resolution
|
Temperature:0.1℃, time:0.1min
|
||||
|
Program Function
|
20A program, fiftyparagraph/program,Can be set20cycles,Maximum number of cycles99order,The program can be linked.
|
||||
|
control mode
|
PID
|
||||
|
Weight(kg)
|
120
|
160
|
280
|
460
|
|
|
Power(KW)
|
2.0(2.7)
|
2.7(3.8)
|
5.0(6.5)
|
6.5(9.5)
|
|
|
Standard configuration
|
Oxygen concentration analyzer1Set, flow meter3individual
|
||||
|
Safety device
|
1.Leakage protection, twoover temperature protection, threeFan overheating alarm, fourFan overcurrent alarm, fiveLow inlet nitrogen pressure alarm, sixDoor open alarm, sevenOxygen concentration analyzer malfunction alarm.
|
||||
|
Power supply(V)
|
AC380±10%V 50±0.5HzThree-phase four-wire+Protect the ground wire
|
||||
|
Compliant with standards
|
GB/T 5170.2、GB/T 2423.2、GJB 150.3
|
||||
Online inquiry